EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Accuracy of cervical pedicle screw placement using a patient-specific template guide system and risk factor analysis for screw perforation: CT-based evaluation of 437 screws

Akira Fukushima, Itaru Oda, Hiroyuki Hasebe, Hirohito Takeuchi, Shigeki Oshima, Ryo Fujita, Hiroki Tanaka, Masanori Fujiya

European Spine Journal · 2025

DOI: 10.1007/s00586-025-09008-3 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Spine Journal, 2025. Verfasst von Akira Fukushima und 7 weiteren Autor:innen. Beteiligte Einrichtung: Hokkaido Orthopaedic Memorial Hospital, Sapporo, Japan. 621akira.fuku@gmail.com. Hauptthemen laut MEDLINE: Pedicle Screws, Cervical Vertebrae, Spinal Fusion, Surgery, Computer-Assisted. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: Cervical pedicle screws (CPS) inserted with template-guided systems (TGS) have a low perforation rate. However, only a few case studies have been reported, and the risk factors for perforation remain unknown. This study aimed to evaluate the accuracy of CPS placement using TGS in a large case series and analyze the risk factors for CPS perforation. METHODS: This was a retrospective clinical evaluation of prospectively enrolled patients. Eighty consecutive patients who underwent CPS insertion using TGS were included in the study. Overall, 437 CPS were inserted using TGS. Computed tomography was used to evaluate CPS positions and radiographic parameters of CPS and vertebrae. Furthermore, comparisons of patient background factors and radiographic parameters were performed between the perforated and non-perforated screw groups. RESULTS: A total of 413 (94.5%) screws were completely inside the pedicle, 22 (5.0%) screws deviated by 2 mm and < 4 mm. Therefore, 435 (99.5%) screws were considered clinically acceptable. The perforation rate was the highest in C4 (12.5%). No neurovascular injury was observed. In comparisons between the perforated screw group and the non-perforated screw group, low height, low weight, low BMI, female sex, fellow surgeon, and narrow pedicle were considered as risk factors for CPS perforation using TGS. CONCLUSION: CPS placement using the TGS showed very high clinical accuracy. Body size, sex, surgeon's experience, and pedicle width may affect the accuracy of CPS placement using TGS.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pedicle ScrewsCervical VertebraeSpinal FusionSurgery, Computer-AssistedHumansMaleFemaleMiddle AgedRetrospective StudiesRisk FactorsAdultAgedTomography, X-Ray ComputedAged, 80 and overYoung Adult

Stichwörter der Autor:innen

Accuracy of cervical pedicle insertionCervical pedicle screwsPatient-specific template-guided systemsRisk factor analysis of screw perforation

Autor:innen und Institutionen

  • Hokkaido Orthopaedic Memorial Hospital, Sapporo, Japan. 621akira.fuku@gmail.com.
  • Hokkaido University Hospital, Sapporo, Japan. 621akira.fuku@gmail.com.
  • Hokkaido Orthopaedic Memorial Hospital, Sapporo, Japan. odaitr@aol.com.
  • Hokkaido Orthopaedic Memorial Hospital, Sapporo, Japan.
  • Hokkaido University Hospital, Sapporo, Japan.
  • Kyushu Rosai Hospital, Kitakyushu, Japan.

Zitieren

APA

Fukushima, A., Oda, I., Hasebe, H., Takeuchi, H., Oshima, S., Fujita, R., Tanaka, H., & Fujiya, M. (2025). Accuracy of cervical pedicle screw placement using a patient-specific template guide system and risk factor analysis for screw perforation: CT-based evaluation of 437 screws. European Spine Journal. https://doi.org/10.1007/s00586-025-09008-3

Vancouver

Fukushima A, Oda I, Hasebe H, Takeuchi H, Oshima S, Fujita R, et al. Accuracy of cervical pedicle screw placement using a patient-specific template guide system and risk factor analysis for screw perforation: CT-based evaluation of 437 screws. European Spine Journal. 2025. doi:10.1007/s00586-025-09008-3

BibTeX
@article{Fukushima2025,
  author = {Fukushima, Akira and Oda, Itaru and Hasebe, Hiroyuki and Takeuchi, Hirohito and Oshima, Shigeki and Fujita, Ryo and Tanaka, Hiroki and Fujiya, Masanori},
  title = {Accuracy of cervical pedicle screw placement using a patient-specific template guide system and risk factor analysis for screw perforation: CT-based evaluation of 437 screws},
  journal = {European Spine Journal},
  year = {2025},
  doi = {10.1007/s00586-025-09008-3}
}
Kostenlos starten →