CT-based radiomics predicts adjacent vertebral fracture after percutaneous vertebral augmentation
European Spine Journal · 2025
DOI: 10.1007/s00586-024-08579-x ↗Kurz gefasst
Fachartikel in der Zeitschrift European Spine Journal, 2025. Verfasst von Jin Yang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Spinal Surgery, Shanghai East Hospital, School of Medicine, Tongji University, Shanghai, 200092, China. Hauptthemen laut MEDLINE: Spinal Fractures, Tomography, X-Ray Computed, Osteoporotic Fractures, Vertebroplasty. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 23 Literaturangaben. Gefördert von: Specialty Feature Construction Project of Shanghai Pudong New Area Health Commission, Joint research project of Health Science and Technology project of Shanghai Pudong New Area Health Commission.
Abstract (Originalsprache)
BACKGROUND: Adjacent vertebral fracture (AVF) is a frequent complication following percutaneous vertebral augmentation (PVA). While radiomics is widely utilized in the field of spinal medicine, its application for assessing the risk of AVF in post-PVA patients remains limited. OBJECTIVE: We aim to develop and validate predictive models using machine learning algorithms for radiomics and clinical risk factors to assess the risk of AVF after PVA. MATERIALS AND METHODS: This retrospective study included 158 patients with osteoporotic vertebral compression fractures who underwent PVA at our hospital, of which 48 patients had AVF within 2 years. The patients were divided into train and test cohorts in a ratio of 7:3. Radiomics features of the surgically intervened vertebrae were extracted from CT images, and selected using Mann-Whitney U-test and LASSO regression to construct a radiomic signature. Machine learning algorithms (SVM and LR) were then employed to integrate the radiomics signature with clinical data to develop predictive models. The performance of the model was assessed using Receiver Operating Characteristic (ROC) curves and calibration curves. RESULTS: Nine optimal radiomics features were selected to form the radiomics model, while five clinical features were identified for the clinical model. The AUCs of the radiomics, clinical, and combined models developed using the SVM algorithm were 0.77, 0.77, and 0.83 on the test cohort, and those of the LR algorithm were 0.78, 0.81, and 0.86. CONCLUSION: Radiomics and machine learning modeling using postoperative CT images demonstrate noteworthy capability in assessing the risk of AVF following PVA.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Spinal Surgery, Shanghai East Hospital, School of Medicine, Tongji University, Shanghai, 200092, China.
- Department of Radiology, Shanghai East Hospital, Tongji University School of Medicine, Shanghai, 200092, China.
- Department of Spinal Surgery, Shanghai East Hospital, School of Medicine, Tongji University, Shanghai, 200092, China. kingspine@163.com.
Förderung
- Specialty Feature Construction Project of Shanghai Pudong New Area Health Commission
- Joint research project of Health Science and Technology project of Shanghai Pudong New Area Health Commission
Zitieren
APA
Yang, J., Zhang, S. B., Yang, S., Ge, X. Y., Ren, C. X., & Wang, S. J. (2025). CT-based radiomics predicts adjacent vertebral fracture after percutaneous vertebral augmentation. European Spine Journal. https://doi.org/10.1007/s00586-024-08579-x
Vancouver
Yang J, Zhang SB, Yang S, Ge XY, Ren CX, Wang SJ. CT-based radiomics predicts adjacent vertebral fracture after percutaneous vertebral augmentation. European Spine Journal. 2025. doi:10.1007/s00586-024-08579-x
BibTeX
@article{Yang2025,
author = {Yang, Jin and Zhang, Shu-Bao and Yang, Shuo and Ge, Xiao-Yong and Ren, Chang-Xu and Wang, Shan-Jin},
title = {CT-based radiomics predicts adjacent vertebral fracture after percutaneous vertebral augmentation},
journal = {European Spine Journal},
year = {2025},
doi = {10.1007/s00586-024-08579-x}
}
EUVIMED