EUVIMEDEUVIMED entdecken
Crossref

Bone density as a risk of early loss of correction after percutaneous posterior spinal fixation for traumatic thoracolumbar fracture: a study on the usefulness of Hounsfield unit values on computed tomography scan

Takeru Akabane iD, Tomoto Suzuki, Yuki Konno, Hiromori Sagae, Makoto Sugita, Hiroshi Hasegawa, Shikou Takada, Tamon Asano, Michiaki Takagi

European Spine Journal · 2025-02 · 34 (2) · 498-505

DOI: 10.1007/s00586-024-08508-y ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Spine Journal, online erschienen am 05.10.2024. Verfasst von Takeru Akabane und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Faculty of Medicine, Yamagata University, 2-2-2 Iida-Nishi, Yamagata, 990-9585, Japan. banebanebane73@yahoo.co.jp. Hauptthemen laut MEDLINE: Spinal Fractures, Thoracic Vertebrae, Lumbar Vertebrae, Tomography, X-Ray Computed. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 25 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: Vertebral Hounsfield unit values on computed tomography scan (CT values) have been found to be correlated with bone density measured using dual-energy X-ray absorptiometry. We hypothesized that low preoperative CT values are risk factors for early loss of correction after percutaneous posterior spinal fixation (PPSF). This study aimed to evaluate the usefulness of measuring preoperative CT values. METHODS: In total, 104 patients underwent PPSF due to traumatic thoracolumbar fracture. Among them, 53 with a range of fixation that was within two vertebrae above and below the fractured vertebra were selected. CT values were measured preoperatively from the most cephalad vertebrae on the fixed vertebrae. Vertebral wedge angle (VWA) and local kyphosis angle (LKA) were measured before and after surgery. participants were classified into progression (P) and nonprogression (NP) groups. The P group comprised patients with LKA progressing > 10° from the immediate postoperative period to 3 months postoperatively. Meanwhile, the NP group included patients without progression. RESULTS: Eight (15.1%) patients were included in the P group. The vertebral CT values were 102.2 ± 36.7 in the P group and 162.4 ± 59.7 in the NP group (p < 0.01). The pedicle CT values were 114.4 ± 45.9 in the P group and 170.8 ± 72.3 in the NP group (p < 0.05). At 2 weeks postoperatively, VWA and LKA of the P group progressed to 9.8° ± 7.0° and 10.9° ± 7.6°, respectively. CONCLUSION: CT values can predict progressive loss of correction after PPSF.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Spinal FracturesThoracic VertebraeLumbar VertebraeTomography, X-Ray ComputedBone DensityFracture Fixation, InternalHumansMaleFemaleAdultMiddle AgedAgedYoung AdultRisk FactorsRetrospective Studies

Stichwörter der Autor:innen

Bone mineral densityHounsfield unit valueLoss of correctionSpinal fixationThoracolumbar fracture

Autor:innen und Institutionen

  • Department of Orthopaedic Surgery, Faculty of Medicine, Yamagata University, 2-2-2 Iida-Nishi, Yamagata, 990-9585, Japan. banebanebane73@yahoo.co.jp.
  • Department of Orthopaedic Surgery, Faculty of Medicine, Yamagata University, 2-2-2 Iida-Nishi, Yamagata, 990-9585, Japan.
  • Yamagata Prefectural Central Hospital, Yamagata, Japan.

ORCID-Profile: Takeru Akabane

Zitieren

APA

Akabane, T., Suzuki, T., Konno, Y., Sagae, H., Sugita, M., Hasegawa, H., Takada, S., Asano, T., & Takagi, M. (2025). Bone density as a risk of early loss of correction after percutaneous posterior spinal fixation for traumatic thoracolumbar fracture: a study on the usefulness of Hounsfield unit values on computed tomography scan. European Spine Journal, 34(2), 498-505. https://doi.org/10.1007/s00586-024-08508-y

Vancouver

Akabane T, Suzuki T, Konno Y, Sagae H, Sugita M, Hasegawa H, et al. Bone density as a risk of early loss of correction after percutaneous posterior spinal fixation for traumatic thoracolumbar fracture: a study on the usefulness of Hounsfield unit values on computed tomography scan. European Spine Journal. 2025;34(2):498-505. doi:10.1007/s00586-024-08508-y

BibTeX
@article{Akabane2025,
  author = {Akabane, Takeru and Suzuki, Tomoto and Konno, Yuki and Sagae, Hiromori and Sugita, Makoto and Hasegawa, Hiroshi and Takada, Shikou and Asano, Tamon and Takagi, Michiaki},
  title = {Bone density as a risk of early loss of correction after percutaneous posterior spinal fixation for traumatic thoracolumbar fracture: a study on the usefulness of Hounsfield unit values on computed tomography scan},
  journal = {European Spine Journal},
  year = {2025},
  volume = {34},
  number = {2},
  pages = {498--505},
  doi = {10.1007/s00586-024-08508-y}
}
Kostenlos starten →