A multibody simulation of the spine for objectification of biomechanical quantities after VBT: a proof of concept and description of baseline data
European Spine Journal · 2024
DOI: 10.1007/s00586-024-08480-7 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Spine Journal, 2024. Verfasst von Jil Frank und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics, Trauma and Reconstructive Surgery, Uniklinik RWTH Aachen, Pauwelsstraße 30, 52074, Aachen, Germany. jil.frank@rwth-aachen…. Hauptthemen laut MEDLINE: Scoliosis. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: RWTH Aachen University.
Abstract (Originalsprache)
Purpose
Vertebral Body Tethering (VBT), an alternative treatment for adolescent idiopathic scoliosis, shows satisfactory post-operative results. However, the biomechanical quantities and consequences after VBT surgery remain largely unknown. Therefore, the aim of this study is to analyze the spinal biomechanics during different motions using a multibody simulation approach.
Methods
The tether and intervertebral compression forces were simulated in a validated spine model during different physiological movements at different pre-tensions and screw positions, while considering the anatomical muscle and ligament properties.
Results
The simulations showed that an augmentation of the pre-tension and an alteration of the screw position have both significant impact on the intervertebral compression and tether forces. The forces also vary depending on the movement performed, with the highest tether forces measured during lateral bending. In the upright position, with a pre-tension of 200 N, the maximum compression force increases by up to 157% compared to the untethered maximum compression force. The screw position can lead to large differences in the distribution of forces in the spine.
Conclusion
The biomechanical data provide a first impression of the forces that occur along the spine during various physiological movements and are consistent with published clinical data. Forces are not evenly distributed along the spine, with higher lumbar forces. The tether forces reach values during lateral bending that can potentially destroy the tether´s integrity and thus may explain the common post-operative complication, namely tether breakage. The results of the model can therefore have an impact on future directions for improved surgical VBT treatment.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedics, Trauma and Reconstructive Surgery, Uniklinik RWTH Aachen, Pauwelsstraße 30, 52074, Aachen, Germany. jil.frank@rwth-aachen.de.
- Teaching and Research Area Experimental Orthopaedics and Trauma Surgery, Uniklinik RWTH Aachen, Aachen, Germany. jil.frank@rwth-aachen.de.
- Department of Orthopaedics, Trauma and Reconstructive Surgery, Uniklinik RWTH Aachen, Pauwelsstraße 30, 52074, Aachen, Germany.
- Institute for Biomechanics, ETH Zurich, Zurich, Switzerland.
- Department of Spine Surgery, Eifelklinik St. Brigida, Simmerath, Germany.
- Teaching and Research Area Experimental Orthopaedics and Trauma Surgery, Uniklinik RWTH Aachen, Aachen, Germany.
ORCID-Profile: Jil Frank, Dominika Ignasiak, Maximilian Praster
Förderung
- RWTH Aachen University
Zitieren
APA
Frank, J., Pishnamaz, M., Ignasiak, D., Trobisch, P. D., Hildebrand, F., & Praster, M. (2024). A multibody simulation of the spine for objectification of biomechanical quantities after VBT: a proof of concept and description of baseline data. European Spine Journal. https://doi.org/10.1007/s00586-024-08480-7
Vancouver
Frank J, Pishnamaz M, Ignasiak D, Trobisch PD, Hildebrand F, Praster M. A multibody simulation of the spine for objectification of biomechanical quantities after VBT: a proof of concept and description of baseline data. European Spine Journal. 2024. doi:10.1007/s00586-024-08480-7
BibTeX
@article{Frank2024,
author = {Frank, Jil and Pishnamaz, Miguel and Ignasiak, Dominika and Trobisch, Per David and Hildebrand, Frank and Praster, Maximilian},
title = {A multibody simulation of the spine for objectification of biomechanical quantities after VBT: a proof of concept and description of baseline data},
journal = {European Spine Journal},
year = {2024},
doi = {10.1007/s00586-024-08480-7}
}
EUVIMED