Multizentrische Studie in der Zeitschrift European Spine Journal, 2023. Verfasst von Clara Berlin und 3 weiteren Autor:innen. Beteiligte Einrichtung: Spine Surgery with Scoliosis Center, Schön Klinik Neustadt, Am Kiebitzberg 10, 23730, Neustadt in Holstein, Germany. CBerlin@schoen-klinik.de. Hauptthemen laut MEDLINE: Scoliosis, Spinal Fusion, Kyphosis, Pedicle Screws. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 40 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: In surgical treatment of adolescent idiopathic scoliosis (AIS), only a few studies measure both, radiological parameters and PROMs and correlate them. METHODS: Prospectively collected AIS-data of one scoliosis-center within a multicenter German-Spine-Society-Study. All patients underwent instrumented posterior spinal correction and fusion with pedicle-screw-dual-rod-systems from 05/2019 to 01/2021. The data were retrospectively analyzed. INCLUSION CRITERIA: age 11-17 years, follow-up (FU) at least 12 months. Clinical data, radiographic parameters, and PROMs (SRS-30-questionnaire) were collected. 100% of patients had X-ray images, 88.2% completed SRS-30. Parameters were given as mean ± SD. Differences and subdivision by lower instrumented vertebra (LIV) were analyzed by students t-test (significancy a = 0.05), associations by Pearson's correlation. RESULT: Total of 51 patients: 15 ± 1.4 years, BMI 20.7 ± 3.7 kg/m2, FU 16.6 ± 6.1 months, fusion length 9.2 ± 2.3 segments, implant density 93 ± 9%, surgical time 215 ± 71 min, mean blood loss 504 ± 360 ml. Mean preoperative Cobb angle of main curve 64 ± 14°, of secondary main curve 46 ± 12°, corrected by 68 ± 11%, 56 ± 17%, respectively. Mean thoracic rib and lumbar hump significantly decreased by - 8.5 ± 7.0° and - 7.7 ± 8.9° (p 0.5) did not significantly change, only LIV-tilt from 24.5 ± 6.7° to 6.5 ± 4.3° (p < 0.05). PROMs significantly improved (p < 0.05), no significant improvement for function/activity (p = 0.4). Preoperative mean total-score was 3.6 ± 0.5, 4.2 ± 0.3 at FU(p < 0.05). Self-image improved in 67%. Moderately strong correlation for PROMs: the better LIV-tilt (r = - 0.5) correction and the shorter surgery time (r = - 0.4), the better SRS-30 total-score. No correlation for curve correction and patient's satisfaction. CONCLUSION: In summary, results of this study demonstrate good surgical correction and significant improvement of most PROMs.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Spine Surgery with Scoliosis Center, Schön Klinik Neustadt, Am Kiebitzberg 10, 23730, Neustadt in Holstein, Germany. CBerlin@schoen-klinik.de.
- Spine Surgery with Scoliosis Center, Schön Klinik Neustadt, Am Kiebitzberg 10, 23730, Neustadt in Holstein, Germany.
Zitieren
APA
Berlin, C., Tielemann, S., Quante, M., & Halm, H. (2023). Correlation of radiographic parameters and patient satisfaction in adolescent idiopathic scoliosis treated with posterior screw-dual-rod instrumentation. European Spine Journal. https://doi.org/10.1007/s00586-023-07849-4
Vancouver
Berlin C, Tielemann S, Quante M, Halm H. Correlation of radiographic parameters and patient satisfaction in adolescent idiopathic scoliosis treated with posterior screw-dual-rod instrumentation. European Spine Journal. 2023. doi:10.1007/s00586-023-07849-4
BibTeX
@article{Berlin2023,
author = {Berlin, Clara and Tielemann, Sophie and Quante, Markus and Halm, Henry},
title = {Correlation of radiographic parameters and patient satisfaction in adolescent idiopathic scoliosis treated with posterior screw-dual-rod instrumentation},
journal = {European Spine Journal},
year = {2023},
doi = {10.1007/s00586-023-07849-4}
}
EUVIMED