Safety and accuracy of cannulated pedicle screw placement in scoliosis surgery: a comparison of robotic-navigation, O-arm-based navigation, and freehand techniques

Chao Li, Zheng Wang, Donglai Li, Yonghao Tian, Suomao Yuan, Lianlei Wang, Xinyu Liu

European Spine Journal · 2023-09 · 32 (9) · 3094-3104

DOI: 10.1007/s00586-023-07710-8 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Spine Journal, online erschienen am 05.06.2023. Verfasst von Chao Li und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedics, Qilu Hospital of Shandong University, Wenhua West Road 107#, Jinan, 250012, Shandong, People's Republic of China. Hauptthemen laut MEDLINE: Pedicle Screws, Scoliosis, Robotic Surgical Procedures, Surgery, Computer-Assisted. Die Arbeit wurde bisher 33-mal zitiert (Crossref) und nennt 33 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Shandong Province, Taishan Scholar Project of Shandong Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To compare the safety and accuracy of cannulated pedicle screw placement using a robotic-navigation technique, O-arm-based navigation technique, or freehand technique. METHODS: This study analyzed 106 consecutive patients who underwent scoliosis surgery. Thirty-two patients underwent robotic-navigation-assisted pedicle screw insertion (Group 1), 34 patients underwent O-arm-based navigation-guided pedicle screw insertion (Group 2), and 40 patients underwent freehand pedicle screw insertion (Group 3). The primary outcome measure was the accuracy of screw placement. Secondary outcome parameters included operation time, blood loss, radiation exposure, and postoperative stay. RESULTS: A total of 2035 cannulated pedicle screws were implanted in 106 patients. The accuracy rate of the first pedicle screw placement during operation was significantly greater in Group 1 (94.7%) than in Group 2 (89.2%; P Group 2 (93.0%) > Group 3 (80.4%; P 0.05). The operation times of Group 1 and Group 2 were significantly longer than that of Group 3 (P < 0.05). CONCLUSION: The robotic-navigation and O-arm-based navigation techniques effectively increased the accuracy and safety of pedicle screw insertion alternative to the freehand technique in scoliosis surgery. Compared with the O-arm-based navigation technique, the robotic-navigation technique increases the mean operation time, but also increases the accuracy of pedicle screw placement. A three-dimensional scan after insertion of the K-wire may increase the accuracy of pedicle screw placement in the O-arm-based navigation technique.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pedicle ScrewsScoliosisRobotic Surgical ProceduresSurgery, Computer-AssistedSpinal FusionHumansImaging, Three-DimensionalTomography, X-Ray ComputedRetrospective Studies

Stichwörter der Autor:innen

NavigationPedicle screwRobotic surgeryRobotic-navigationScoliosis

Autor:innen und Institutionen

  • Department of Orthopedics, Qilu Hospital of Shandong University, Wenhua West Road 107#, Jinan, 250012, Shandong, People's Republic of China.
  • Department of Orthopedics, Qilu Hospital of Shandong University, Wenhua West Road 107#, Jinan, 250012, Shandong, People's Republic of China. wllspine@163.com.
  • Department of Orthopedics, Qilu Hospital of Shandong University, Wenhua West Road 107#, Jinan, 250012, Shandong, People's Republic of China. newyuliu@163.com.

Förderung

  • National Natural Science Foundation of China
  • Natural Science Foundation of Shandong Province
  • Taishan Scholar Project of Shandong Province

Zitieren

APA

Li, C., Wang, Z., Li, D., Tian, Y., Yuan, S., Wang, L., & Liu, X. (2023). Safety and accuracy of cannulated pedicle screw placement in scoliosis surgery: a comparison of robotic-navigation, O-arm-based navigation, and freehand techniques. European Spine Journal, 32(9), 3094-3104. https://doi.org/10.1007/s00586-023-07710-8

Vancouver

Li C, Wang Z, Li D, Tian Y, Yuan S, Wang L, et al. Safety and accuracy of cannulated pedicle screw placement in scoliosis surgery: a comparison of robotic-navigation, O-arm-based navigation, and freehand techniques. European Spine Journal. 2023;32(9):3094-3104. doi:10.1007/s00586-023-07710-8

BibTeX
@article{Li2023,
  author = {Li, Chao and Wang, Zheng and Li, Donglai and Tian, Yonghao and Yuan, Suomao and Wang, Lianlei and Liu, Xinyu},
  title = {Safety and accuracy of cannulated pedicle screw placement in scoliosis surgery: a comparison of robotic-navigation, O-arm-based navigation, and freehand techniques},
  journal = {European Spine Journal},
  year = {2023},
  volume = {32},
  number = {9},
  pages = {3094--3104},
  doi = {10.1007/s00586-023-07710-8}
}
Kostenlos starten →