Surgical smoke exposure to patients and to healthcare workers in the operating room: a quantitative assessment
Journal of Anesthesia · 2026
DOI: 10.1007/s00540-026-03672-5 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Anesthesia, 2026. Verfasst von Shuse Matsuyama und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology, Dokkyo Medical University Saitama Medical Center, 2-1-50, Minami-Koshigaya, Koshigaya, Saitama, 343-8555, Japan. Hauptthemen laut MEDLINE: Operating Rooms, Smoke, Electrosurgery, Occupational Exposure. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Japan Society for the Promotion of Science London, Dokkyo Medical University.
Abstract (Originalsprache)
Background
Surgical smoke produced by the use of an electrosurgical unit may have a negative effect to patients and healthcare workers in the operating room, but studies on this problem are insufficient.
Methods
In 100 situations in which patients were undergoing four types of surgery under general anesthesia, the count of airborne particles (in 1.415 L) was measured using a particle counter to see possible differences at the patients and at the anesthesiologists, during different types of surgery, and at several locations.
Results
The airborne particles during the use of an electrosurgical unit were significantly higher than before its use, both at the patient’s head (median: 56/L vs 3,514/L; 95%CI for the median difference: 769–7,699/L) and at the anesthesiologist’s position (230/L vs 6,907/L; 95%CI for the median difference: 2,945–13,196/L) ( p < 0.0001). The airborne particles were significantly higher during cardiovascular surgery than during open abdominal surgery (median difference in increase: 8,439/L), significantly higher during open abdominal surgery than during head and neck surgery (2,654/L), and significantly higher during head and neck surgery than during laparoscopic surgery (1,442/L) (all p < 0.0001), and were high anywhere in the operating room and even outside the operating room door (always > 2,000/L).
Conclusions
During the use of an electrosurgical unit, both the patients and healthcare workers are at increased risk of being exposed to high concentrations of airborne particles derived from surgical smoke.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Anesthesiology, Dokkyo Medical University Saitama Medical Center, 2-1-50, Minami-Koshigaya, Koshigaya, Saitama, 343-8555, Japan.
- Department of Anesthesiology, Dokkyo Medical University Saitama Medical Center, 2-1-50, Minami-Koshigaya, Koshigaya, Saitama, 343-8555, Japan. asaita@dokkyomed.ac.jp.
- Institute of Urban Innovation, Yokohama National University, 9-5 Tokiwadai, Hodogaya-Ku, , Yokohama City, 240-8501, Japan.
Förderung
- Japan Society for the Promotion of Science London
- Dokkyo Medical University
Zitieren
APA
Matsuyama, S., Asai, T., Saito, T., Kiyono, T., & Okuda, Y. (2026). Surgical smoke exposure to patients and to healthcare workers in the operating room: a quantitative assessment. Journal of Anesthesia. https://doi.org/10.1007/s00540-026-03672-5
Vancouver
Matsuyama S, Asai T, Saito T, Kiyono T, Okuda Y. Surgical smoke exposure to patients and to healthcare workers in the operating room: a quantitative assessment. Journal of Anesthesia. 2026. doi:10.1007/s00540-026-03672-5
BibTeX
@article{Matsuyama2026,
author = {Matsuyama, Shuse and Asai, Takashi and Saito, Tomoyuki and Kiyono, Tomoki and Okuda, Yasuhisa},
title = {Surgical smoke exposure to patients and to healthcare workers in the operating room: a quantitative assessment},
journal = {Journal of Anesthesia},
year = {2026},
doi = {10.1007/s00540-026-03672-5}
}