Accuracy of non-invasive core temperature monitoring in infant and toddler patients: a prospective observational study
Journal of Anesthesia · 2024
DOI: 10.1007/s00540-024-03404-7 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Journal of Anesthesia, 2024. Verfasst von Tasuku Fujii und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology, Nagoya University Hospital, 65 Tsurumai-cho, Showa-ku, Nagoya, 466-8550, Japan. plus9@med.nagoya-u.ac.jp. Hauptthemen laut MEDLINE: Body Temperature. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Nagoya University.
Abstract (Originalsprache)
Purpose
Careful perioperative temperature management is important because it influences clinical outcomes. In pediatric patients, the esophageal temperature is the most accurate indicator of core temperature. However, it requires probe insertion into the body cavity, which is mildly invasive. Therefore, a non-invasive easily and continuously temperature monitor system is ideal. This study aimed to assess the accuracy of Temple Touch Pro™ (TTP), a non-invasive temperature monitoring using the heat flux technique, compared with esophageal (Tesoph) and rectal (Trect) temperature measurements in pediatric patients, especially in infants and toddlers.
Methods
This single-center prospective observational study included 40 pediatric patients (< 3 years old) who underwent elective non-cardiac surgery. The accuracy of TTP was analyzed using Bland–Altman analysis and compared with Tesoph or Trect temperature measurements. The error was within ± 0.5 °C and was considered clinically acceptable.
Results
The bias ± precision between TTP and Tesoph was 0.09 ± 0.28 °C, and 95% limits of agreement were – 0.48 to 0.65 °C (error within ± 0.5 °C: 94.0%). The bias ± precision between TTP and Trect was 0.41 ± 0.38 °C and 95% limits of agreement were – 0.35 to 1.17 °C (error within ± 0.5 °C: 68.5%). In infants, bias ± precision with 95% limits of agreement were 0.10 ± 0.30 °C with – 0.50 to 0.69 °C (TTP vs. Tesoph) and 0.35 ± 0.29 °C with – 0.23 to 0.92 °C (TTP vs. Trect).
Conclusion
Core temperature measurements using TTP in infants and toddlers were more accurate with Tesoph than with Trect. In the future, non-invasive TTP temperature monitoring will help perioperative temperature management in pediatric patients.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Anesthesiology, Nagoya University Hospital, 65 Tsurumai-cho, Showa-ku, Nagoya, 466-8550, Japan. plus9@med.nagoya-u.ac.jp.
- Department of Anesthesiology, Nagoya University Hospital, 65 Tsurumai-cho, Showa-ku, Nagoya, 466-8550, Japan.
- Department of Anesthesiology, Nagoya University Graduate School of Medicine, Nagoya, Japan.
ORCID-Profile: Tasuku Fujii
Förderung
- Nagoya University
Zitieren
APA
Fujii, T., Takakura, M., Taniguchi, T., & Nishiwaki, K. (2024). Accuracy of non-invasive core temperature monitoring in infant and toddler patients: a prospective observational study. Journal of Anesthesia. https://doi.org/10.1007/s00540-024-03404-7
Vancouver
Fujii T, Takakura M, Taniguchi T, Nishiwaki K. Accuracy of non-invasive core temperature monitoring in infant and toddler patients: a prospective observational study. Journal of Anesthesia. 2024. doi:10.1007/s00540-024-03404-7
BibTeX
@article{Fujii2024,
author = {Fujii, Tasuku and Takakura, Masashi and Taniguchi, Tomoya and Nishiwaki, Kimitoshi},
title = {Accuracy of non-invasive core temperature monitoring in infant and toddler patients: a prospective observational study},
journal = {Journal of Anesthesia},
year = {2024},
doi = {10.1007/s00540-024-03404-7}
}
EUVIMED