EUVIMEDEUVIMED entdecken
Querschnittstudie

Relationship between epidural catheter migration beneath the skin and subcutaneous fat thickness assessed using postoperative CT imaging: a retrospective cross-sectional study

Natsumi Sakamoto, Mitsuhiro Matsuo iD, Tomonori Takazawa

Journal of Anesthesia · 2024

DOI: 10.1007/s00540-024-03374-w ↗

Kurz gefasst

Querschnittstudie in der Zeitschrift Journal of Anesthesia, 2024. Verfasst von Natsumi Sakamoto und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology, Faculty of Medicine, University of Toyama, 2630 Sugitani, Toyama, 930-0194, Japan. Hauptthemen laut MEDLINE: Subcutaneous Fat, Tomography, X-Ray Computed, Anesthesia, Epidural, Foreign-Body Migration. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 17 Literaturangaben. Gefördert von: Japan Society for the Promotion of Science.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: The causes of epidural catheter migration beneath the skin have not been previously investigated. We hypothesized that greater subcutaneous fat thickness might be associated with increased catheter migration beneath the skin. METHODS: We conducted a retrospective cross-sectional study of patients who had undergone combined general and epidural anesthesia, selecting individuals who received thoracic and abdominal CT scans within the first 5 postoperative days. Needle depth was defined as the distance from the needle tip to the skin surface when the anesthesiologist determined that the needle tip had reached the epidural space. We measured the length of the epidural catheter from the skin surface to the epidural space (catheter length), and subcutaneous fat thickness (fat thickness) using CT imaging. Migration distance was calculated by subtracting needle depth from catheter length. RESULTS: We analyzed 127 patients (72 males), all undergoing epidural catheter insertion in the left lateral decubitus position via a paramedian approach. The median age of the patients was 71 years. Epidural catheters were postoperatively found to substantially curve beneath the skin. Regression analysis revealed no significant influence of fat thickness on catheter length (regression coefficient 0.10, 95% confidence interval [CI]: - 0.17, 0.38). However, it indicated a positive correlation between fat thickness and needle depth (regression coefficient 0.50, 95% CI: 0.30, 0.70), and a negative correlation between fat thickness and migration distance (regression coefficient - 0.40, 95% CI: - 0.65, - 0.14). CONCLUSION: We found a negative correlation between epidural catheter migration beneath the skin and subcutaneous fat thickness. Anesthesiologists should be aware of the possibility of substantial subcutaneous curving of the catheter, especially in patients with scant subcutaneous fat.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Subcutaneous FatTomography, X-Ray ComputedAnesthesia, EpiduralForeign-Body MigrationEpidural SpaceSkinHumansMaleCross-Sectional StudiesRetrospective StudiesFemaleAgedMiddle AgedCathetersAged, 80 and overPostoperative PeriodAdult

Stichwörter der Autor:innen

Epidural anesthesiaEpidural spaceNeuraxial anesthesiaParamedian approachSynapse vincent

Autor:innen und Institutionen

  • Department of Anesthesiology, Faculty of Medicine, University of Toyama, 2630 Sugitani, Toyama, 930-0194, Japan.
  • Department of Anesthesiology, Faculty of Medicine, University of Toyama, 2630 Sugitani, Toyama, 930-0194, Japan. mmatsuo@med.u-toyama.ac.jp.

ORCID-Profile: Mitsuhiro Matsuo

Förderung

  • Japan Society for the Promotion of Science

Zitieren

APA

Sakamoto, N., Matsuo, M., & Takazawa, T. (2024). Relationship between epidural catheter migration beneath the skin and subcutaneous fat thickness assessed using postoperative CT imaging: a retrospective cross-sectional study. Journal of Anesthesia. https://doi.org/10.1007/s00540-024-03374-w

Vancouver

Sakamoto N, Matsuo M, Takazawa T. Relationship between epidural catheter migration beneath the skin and subcutaneous fat thickness assessed using postoperative CT imaging: a retrospective cross-sectional study. Journal of Anesthesia. 2024. doi:10.1007/s00540-024-03374-w

BibTeX
@article{Sakamoto2024,
  author = {Sakamoto, Natsumi and Matsuo, Mitsuhiro and Takazawa, Tomonori},
  title = {Relationship between epidural catheter migration beneath the skin and subcutaneous fat thickness assessed using postoperative CT imaging: a retrospective cross-sectional study},
  journal = {Journal of Anesthesia},
  year = {2024},
  doi = {10.1007/s00540-024-03374-w}
}
Kostenlos starten →