EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Comparison of leak fraction between the laryngeal mask airway and endotracheal tube during anesthesia: a single-center retrospective study

Seiichi Azuma, Masaaki Asamoto iD, Shinichi Akabane, Mariko Ezaka, Mikiya Otsuji, Kanji Uchida

Journal of Anesthesia · 2024

DOI: 10.1007/s00540-024-03364-y ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Anesthesia, 2024. Verfasst von Seiichi Azuma und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology and Pain Relief Center, The University of Tokyo Hospital, Hongo 7-3-1, Bunkyo-Ku, Tokyo, 113-8655, Japan. Hauptthemen laut MEDLINE: Laryngeal Masks, Intubation, Intratracheal. Die Arbeit nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: The University of Tokyo.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The use of the laryngeal mask airway (LMA), which offers the benefits of ease in insertion and prevention of tracheal damage, is associated with a risk of flow leakage. This study analyzed our extensive database to compare leakage associated with the use of LMA and endotracheal tube (ETT). Adult patients who underwent chest wall, abdominal wall, inguinal region, limb, transurethral, or transvaginal surgery and received either LMA or ETT between January 2007 and March 2020 were included. The leak fraction was calculated as (inspiratory tidal volume−expiratory tidal volume)/(inspiratory tidal volume) × 100% every minute during intraoperative stable positive pressure ventilation. The median leak fraction was calculated for each case. The leak fraction in the LMA group demonstrated a left-skewed distribution with a larger proportion of excessive leak fraction. The leak fraction in the LMA group (median, 7.9%; interquartile range, 4.8–11.4%) was significantly lower than that in the ETT group (median, 9.1%; interquartile range: 5.5–12.4%; P < 0.001). This tendency was consistent across subgroups divided by sex, age, type of surgery, and ventilation mode. We propose that LMA provides leakage comparable to or less than ETT in most cases if stable positive pressure ventilation is achieved.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Laryngeal MasksIntubation, IntratrachealHumansFemaleRetrospective StudiesMaleMiddle AgedAdultAgedTidal VolumeAnesthesia, GeneralAnesthesia

Stichwörter der Autor:innen

Laryngeal maskLeakagePositive pressure ventilationTracheal intubation

Autor:innen und Institutionen

  • Department of Anesthesiology and Pain Relief Center, The University of Tokyo Hospital, Hongo 7-3-1, Bunkyo-Ku, Tokyo, 113-8655, Japan.
  • Graduate School of Medicine, The University of Tokyo, Tokyo, Japan.
  • Department of Anesthesiology and Pain Relief Center, The University of Tokyo Hospital, Hongo 7-3-1, Bunkyo-Ku, Tokyo, 113-8655, Japan. ASAMOTOM-ANE@h.u-tokyo.ac.jp.
  • Department of Anesthesiology, Tokyo Teishin Hospital, Tokyo, Japan.

ORCID-Profile: Masaaki Asamoto

Förderung

  • The University of Tokyo

Zitieren

APA

Azuma, S., Asamoto, M., Akabane, S., Ezaka, M., Otsuji, M., & Uchida, K. (2024). Comparison of leak fraction between the laryngeal mask airway and endotracheal tube during anesthesia: a single-center retrospective study. Journal of Anesthesia. https://doi.org/10.1007/s00540-024-03364-y

Vancouver

Azuma S, Asamoto M, Akabane S, Ezaka M, Otsuji M, Uchida K. Comparison of leak fraction between the laryngeal mask airway and endotracheal tube during anesthesia: a single-center retrospective study. Journal of Anesthesia. 2024. doi:10.1007/s00540-024-03364-y

BibTeX
@article{Azuma2024,
  author = {Azuma, Seiichi and Asamoto, Masaaki and Akabane, Shinichi and Ezaka, Mariko and Otsuji, Mikiya and Uchida, Kanji},
  title = {Comparison of leak fraction between the laryngeal mask airway and endotracheal tube during anesthesia: a single-center retrospective study},
  journal = {Journal of Anesthesia},
  year = {2024},
  doi = {10.1007/s00540-024-03364-y}
}
Kostenlos starten →