EUVIMEDEUVIMED entdecken
Crossref

A comparison of invasive arterial blood pressure measurement with oscillometric non-invasive blood pressure measurement in patients with sepsis

Ziqing Jiang, Shaoying Li, Lin Wang, Feng Yu, Yanping Zeng, Hongbo Li, Jun Li, Zhanfeng Zhang, Junling Zuo

Journal of Anesthesia · 2024

DOI: 10.1007/s00540-023-03304-2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Anesthesia, 2024. Verfasst von Ziqing Jiang und 8 weiteren Autor:innen. Beteiligte Einrichtung: Candidate of Master's Degree, The First Clinical Medical College, Guangzhou University of Chinese Medicine, Baiyun District, Guangzhou, Guangdong Pro…. Hauptthemen laut MEDLINE: Arterial Pressure, Sepsis. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 34 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: This study aimed to compare non-invasive oscillometric blood pressure (NIBP) measurement with invasive arterial blood pressure (IBP) measurement in patients with sepsis. METHODS: We conducted a retrospective study to evaluate the agreement between IBP and NIBP using the Medical Information Mart for Intensive Care IV (MIMIC-IV) database. Paired blood pressure measurements of mean arterial pressure (MAP), systolic blood pressure (SBP), and diastolic blood pressure (DBP) were compared using Bland-Altman analysis and paired Student's t test. We also focus on the effect of norepinephrine (NE) on the agreement between the two methods and the association between blood pressure and mortality during intensive care unit (ICU) stay. RESULTS: A total of 96,673 paired blood pressure measurements from 6060 unique patients were analyzed in the study. In Bland-Altman analysis, the bias (± SD, 95% limits of agreement) was 6.21 mmHg (± 12.05 mmHg, - 17.41 to 29.83 mmHg) for MAP, 0.39 mmHg (± 19.25 mmHg, - 37.34 to 38.12 mmHg) for SBP, and 0.80 mmHg (± 12.92 mmHg, - 24.52 to 26.12 mmHg) for DBP between the two techniques. Similarly, large limits of agreement were shown in different groups of NE doses. NE doses significantly affected the agreement between IBP and NIBP. SBP between the two methods gave an inconsistent assessment of patients' risk of ICU mortality. CONCLUSION: IBP and NIBP were not interchangeable in septic patients. Clinicians should be aware that non-invasive MAP was clinically and significantly underestimated invasive MAP.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arterial PressureSepsisHumansBlood PressureBlood Pressure DeterminationRetrospective StudiesNorepinephrineBlood Pressure Monitors

Stichwörter der Autor:innen

Invasive blood pressure measurementNon-invasive blood pressure measurementSepsis

Substanzen

Norepinephrine

Autor:innen und Institutionen

  • Candidate of Master's Degree, The First Clinical Medical College, Guangzhou University of Chinese Medicine, Baiyun District, Guangzhou, Guangdong Province, China.
  • The First Affiliated Hospital of Guangzhou University of Chinese Medicine, 16 Jichang Road, Baiyun District, Guangzhou, Guangdong Province, China.
  • The First Affiliated Hospital of Guangzhou University of Chinese Medicine, 16 Jichang Road, Baiyun District, Guangzhou, Guangdong Province, China. dr.zuo@163.com.

Zitieren

APA

Jiang, Z., Li, S., Wang, L., Yu, F., Zeng, Y., Li, H., Li, J., Zhang, Z., & Zuo, J. (2024). A comparison of invasive arterial blood pressure measurement with oscillometric non-invasive blood pressure measurement in patients with sepsis. Journal of Anesthesia. https://doi.org/10.1007/s00540-023-03304-2

Vancouver

Jiang Z, Li S, Wang L, Yu F, Zeng Y, Li H, et al. A comparison of invasive arterial blood pressure measurement with oscillometric non-invasive blood pressure measurement in patients with sepsis. Journal of Anesthesia. 2024. doi:10.1007/s00540-023-03304-2

BibTeX
@article{Jiang2024,
  author = {Jiang, Ziqing and Li, Shaoying and Wang, Lin and Yu, Feng and Zeng, Yanping and Li, Hongbo and Li, Jun and Zhang, Zhanfeng and Zuo, Junling},
  title = {A comparison of invasive arterial blood pressure measurement with oscillometric non-invasive blood pressure measurement in patients with sepsis},
  journal = {Journal of Anesthesia},
  year = {2024},
  doi = {10.1007/s00540-023-03304-2}
}