Stroke volume variation and dynamic arterial elastance predict fluid responsiveness even in thoracoscopic esophagectomy: a prospective observational study
Journal of Anesthesia · 2023
DOI: 10.1007/s00540-023-03256-7 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Journal of Anesthesia, 2023. Verfasst von Yukiko Hikasa und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesia and Intensive Care, National Cancer Center Hospital, 5-1-1, Tsukiji, Chuo-ku, Tokyo, 104-0045, Japan. yhikasa@ncc.go.jp. Hauptthemen laut MEDLINE: Esophagectomy, Fluid Therapy. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 34 Literaturangaben. Gefördert von: Edwards Lifesciences.
Themen: Schlaganfall
Abstract (Originalsprache)
PURPOSE: It remains unknown whether stroke volume variation (SVV), pulse pressure variation (PPV), and dynamic arterial elastance (Eadyn) are suitable for monitoring fluid management during thoracoscopic esophagectomy (TE) in the prone position with one-lung ventilation and artificial pneumothorax. Our study aimed to evaluate the accuracy of SVV, PVV, and Eadyn in predicting the fluid responsiveness in these patients. METHODS: We recruited 24 patients who had undergone TE. Patients with a mean arterial blood pressure ≤ 65 mmHg received a 200-ml bolus of 6% hydroxyethyl starch over 10 min. Fluid responders showed the stroke volume index ≥ 15% 5 min after the fluid bolus. Receiver operating characteristic (ROC) curves were generated and area under the ROC curve (AUROC) was calculated. RESULTS: We obtained 61 fluid bolus data points, of which 20 were responders and 41 were non-responders. The median SVV before the fluid bolus in responders was significantly higher than that in non-responders (18% [interquartile range (IQR) 13-21] vs. 12% [IQR 8-15], P = 0.001). Eadyn was significantly lower in responders than in non-responders (0.55 [IQR 0.45-0.78] vs. 0.91 [IQR 0.67-1.00], P < 0.001). There was no difference in the PPV between the groups. The AUROC was 0.76 for SVV (95% confidence interval [CI] 0.62-0.89, P = 0.001), 0.56 for PPV (95% CI 0.41-0.71, P = 0.44), and 0.82 for Eadyn (95% CI 0.69-0.95, P < 0.001). CONCLUSIONS: SVV and Eadyn are reliable parameters for predicting fluid responsiveness in patients undergoing TE.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Anesthesia and Intensive Care, National Cancer Center Hospital, 5-1-1, Tsukiji, Chuo-ku, Tokyo, 104-0045, Japan. yhikasa@ncc.go.jp.
- Department of Anesthesiology and Resuscitology, Okayama University Hospital, Okayama, Japan.
- Department of Gastroenterological Surgery Transplant and Surgical Oncology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama, Japan.
- Department of Surgery, Hiroshima City Hiroshima Citizens Hospital, Hiroshima, Japan.
Förderung
- Edwards Lifesciences
Zitieren
APA
Hikasa, Y., Suzuki, S., Tanabe, S., Noma, K., Shirakawa, Y., Fujiwara, T., & Morimatsu, H. (2023). Stroke volume variation and dynamic arterial elastance predict fluid responsiveness even in thoracoscopic esophagectomy: a prospective observational study. Journal of Anesthesia. https://doi.org/10.1007/s00540-023-03256-7
Vancouver
Hikasa Y, Suzuki S, Tanabe S, Noma K, Shirakawa Y, Fujiwara T, et al. Stroke volume variation and dynamic arterial elastance predict fluid responsiveness even in thoracoscopic esophagectomy: a prospective observational study. Journal of Anesthesia. 2023. doi:10.1007/s00540-023-03256-7
BibTeX
@article{Hikasa2023,
author = {Hikasa, Yukiko and Suzuki, Satoshi and Tanabe, Shunsuke and Noma, Kazuhiro and Shirakawa, Yasuhiro and Fujiwara, Toshiyoshi and Morimatsu, Hiroshi},
title = {Stroke volume variation and dynamic arterial elastance predict fluid responsiveness even in thoracoscopic esophagectomy: a prospective observational study},
journal = {Journal of Anesthesia},
year = {2023},
doi = {10.1007/s00540-023-03256-7}
}