Multizentrische Studie in der Zeitschrift Journal of Gastroenterology, online erschienen am 12.05.2025. Verfasst von Yohei Yabuuchi und 22 weiteren Autor:innen. Beteiligte Einrichtung: Department of Gastroenterology, Kobe City Medical Center General Hospital, 2-1-1 Minatojima Minamimachi, Chuo-ku, Kobe, Hyogo, 650-0047, Japan. yohei…. Hauptthemen laut MEDLINE: Stomach Neoplasms, Endoscopic Mucosal Resection, Lymphatic Metastasis. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 25 Literaturangaben. Gefördert von: Japan Society for the Promotion of Science.
Abstract (Originalsprache)
BACKGROUND: The eCura system is a widely used risk-scoring model for predicting lymph node metastasis (LNM) after non-curative endoscopic submucosal dissection (ESD) for early gastric cancer (EGC), but its external validation is limited. Recently, the W-eCura score, a modified version, was proposed. We aimed to validate the eCura system and compare its discriminatory performance with the W-eCura score. METHODS: A multicenter retrospective study was conducted using data from 19 Japanese institutions. The patients who underwent ESD for EGC followed by gastrectomy with lymph node dissection were included. The predictive performance of the eCura system, including calibration and discrimination, was evaluated and its discrimination was compared with the W-eCura score. RESULTS: Among 901 eligible patients, 65 cases (7.2%) showed LNM. The eCura system demonstrated good calibration, with a calibration-in-the-large of -0.008 (95% confidence interval [CI] -0.024-0.010), an observed-to-expected ratio of 0.905 (95% CI 0.707-1.121), and a calibration slope of 0.975 (95% CI 0.692-1.257). Discrimination was also good, with a C-statistic of 0.741 (95% CI 0.676-0.806). In patients evaluable for both systems, the C-statistics for the eCura system and W-eCura score were 0.745 (95% CI 0.675-0.816) and 0.750 (95% CI 0.684-0.817), respectively, showing no significant difference (P = 0.547). CONCLUSIONS: The eCura system was validated as a reliable tool for predicting LNM following ESD in real-world clinical settings.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Gastroenterology, Kobe City Medical Center General Hospital, 2-1-1 Minatojima Minamimachi, Chuo-ku, Kobe, Hyogo, 650-0047, Japan. yohei_yabuuchi@kcho.jp.
- Department of Gastroenterology, Shizuoka General Hospital, Shizuoka, Japan.
- Department of Gastroenterology and Hepatology, Kobe City Nishi-Kobe Medical Center, Hyogo, Japan.
- Department of Gastroenterology and Hepatology, Japanese Red Cross Wakayama Medical Center, Wakayama, Japan.
- Department of Gastroenterology, Kyoto Medical Center, Kyoto, Japan.
- Department of Gastroenterology and Hepatology, Osaka Red Cross Hospital, Osaka, Japan.
ORCID-Profile: Yohei Yabuuchi
Förderung
- Japan Society for the Promotion of Science
Zitieren
APA
Yabuuchi, Y., Masui, Y., Kumagai, K., Iwagami, H., Murai, K., Setoyama, T., Tochio, T., Utsumi, T., Yoshikawa, T., Araki, O., Murakami, S., Kitami, M., Matsuura, K., Kanda, N., Hishitani, E., Tanaka, J., Marui, S., Ikuta, K., Yoshida, H., …, & KONOE Project (2025). External validation of the eCura system and comparison with the W-eCura score for predicting lymph node metastasis after non-curative endoscopic submucosal dissection for early gastric cancer: a multicenter retrospective cohort study. Journal of Gastroenterology, 60(7), 829-837. https://doi.org/10.1007/s00535-025-02261-9
Vancouver
Yabuuchi Y, Masui Y, Kumagai K, Iwagami H, Murai K, Setoyama T, et al. External validation of the eCura system and comparison with the W-eCura score for predicting lymph node metastasis after non-curative endoscopic submucosal dissection for early gastric cancer: a multicenter retrospective cohort study. Journal of Gastroenterology. 2025;60(7):829-837. doi:10.1007/s00535-025-02261-9
BibTeX
@article{Yabuuchi2025,
author = {Yabuuchi, Yohei and Masui, Yuichi and Kumagai, Ken and Iwagami, Hiroyoshi and Murai, Katsuyuki and Setoyama, Takeshi and Tochio, Tomomasa and Utsumi, Takahiro and Yoshikawa, Takaaki and Araki, Osamu and Murakami, Shintaro and Kitami, Motoya and Matsuura, Kenshi and Kanda, Naoki and Hishitani, Eriko and Tanaka, Junya and Marui, Saiko and Ikuta, Kozo and Yoshida, Hiroyuki and Nishikawa, Yoshitaka and Nakanishi, Yuki and Seno, Hiroshi and KONOE Project, KONOE Project},
title = {External validation of the eCura system and comparison with the W-eCura score for predicting lymph node metastasis after non-curative endoscopic submucosal dissection for early gastric cancer: a multicenter retrospective cohort study},
journal = {Journal of Gastroenterology},
year = {2025},
volume = {60},
number = {7},
pages = {829--837},
doi = {10.1007/s00535-025-02261-9}
}