EUVIMEDEUVIMED entdecken
VergleichsstudieRandomisierte kontrollierte StudieOpen Access · CC BY 4.0

Comparison of learning curves and cross-over effects using articulating laparoscopic instruments versus standard laparoscopic instruments

Jean-Paul Bereuter, Maximiliano Emmanuel Ceron Malpica, Mark Enrik Geissler, Josephine Runge, Jasmin Hasanovic, Anne Selbmann, Rona Berit Geissler, Grit Krause-Jüttler, Alexander Kern, Jürgen Weitz, Marius Distler, Felix von Bechtolsheim und 2 weitere

Surgical Endoscopy · 2026-08 · 40 (8) · 6889-6901

DOI: 10.1007/s00464-026-12977-1 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Surgical Endoscopy, online erschienen am 19.06.2026. Verfasst von Jean-Paul Bereuter und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Visceral, Thoracic and Vascular Surgery, Faculty of Medicine and University Hospital Carl Gustav Carus, TUD Dresden University of Techn…. Hauptthemen laut MEDLINE: Learning Curve, Laparoscopy, Laparoscopes. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Technische Universität Dresden.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Minimally invasive surgery evolves continuously with novel tools complementing standard laparoscopic instruments (SLI). Articulating laparoscopic instruments (ALI) provide enhanced dexterity resembling robotic systems while remaining more affordable and accessible. However, comparative data on their learning curve and performance are limited. This study investigated ALI training and performance in a controlled simulator setting.

Methods

Fifty-three medical students participated. After baseline measurement, all participants underwent the same modified Fundamentals of Laparoscopic Surgery (FLS) training curriculum but were randomized in either using ALI or SLI. Learning curves were tracked for the Peg transfer and suture and knot tasks until a predefined proficiency level was reached. All participants then completed final assessments using both instrument types. The primary endpoint was peak force; secondary endpoints included instrument motion metrics, task time, error rate, and SURG-TLX workload scores.

Results

The ALI group demonstrated a slower learning curve in the Peg transfer task compared to the SLI group based on task time ( p < 0.001), peak force ( p = 0.02), and path length ( p < 0.001). In the final assessment, peak force was comparable between groups (Peg: p = 0.17; Suture: p = 0.28), while ALI use resulted in greater path length (Peg: p < 0.001; Suture: p = 0.01) and longer task time ( p < 0.001). Error rates and SURG-TLX scores did not differ. In the crossover assessment, prior ALI training resulted in comparable results for SLI for most parameters, including peak force (Peg: p = 0.97, suture: p = 0.05), instrument speed (Peg: p = 0.13, suture: p = 0.27) or error rate (Peg: p = 0.06; suture: p = 0.21).

Conclusion

Although ALI require a longer learning curve, training with these instruments transfers effectively to standard laparoscopic skills. Their robotic-like motion and accessibility support incorporating ALI into surgical education.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Learning CurveLaparoscopyLaparoscopesHumansClinical CompetenceCross-Over StudiesSimulation TrainingMaleFemaleSuture Techniques

Stichwörter der Autor:innen

Articulating instrumentsLaparoscopic skill analysisMinimally invasive surgery

Autor:innen und Institutionen

  • Department of Visceral, Thoracic and Vascular Surgery, Faculty of Medicine and University Hospital Carl Gustav Carus, TUD Dresden University of Technology, Fetscherstraße 74, 01307, Dresden, Germany. jean-paul.bereuter@…
  • Surgical Skills Lab Dresden, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany. jean-paul.bereuter@ukdd.de.
  • Surgical Skills Lab Dresden, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany.
  • Department of General, Visceral and Thoracic Surgery, Proctology, Helios Klinikum Pirna, Pirna, Germany.
  • Department of Visceral, Thoracic and Vascular Surgery, Faculty of Medicine and University Hospital Carl Gustav Carus, TUD Dresden University of Technology, Fetscherstraße 74, 01307, Dresden, Germany.
  • Centre for Tactile Internet With Human-in-the-Loop (CeTI), TUD Dresden University of Technology, Dresden, Germany.

Förderung

  • Technische Universität Dresden

Zitieren

APA

Bereuter, J. P., Malpica, M. E. C., Geissler, M. E., Runge, J., Hasanovic, J., Selbmann, A., Geissler, R. B., Krause-Jüttler, G., Kern, A., Weitz, J., Distler, M., von Bechtolsheim, F., Dobroschke, J., & Oehme, F. (2026). Comparison of learning curves and cross-over effects using articulating laparoscopic instruments versus standard laparoscopic instruments. Surgical Endoscopy, 40(8), 6889-6901. https://doi.org/10.1007/s00464-026-12977-1

Vancouver

Bereuter JP, Malpica MEC, Geissler ME, Runge J, Hasanovic J, Selbmann A, et al. Comparison of learning curves and cross-over effects using articulating laparoscopic instruments versus standard laparoscopic instruments. Surgical Endoscopy. 2026;40(8):6889-6901. doi:10.1007/s00464-026-12977-1

BibTeX
@article{Bereuter2026,
  author = {Bereuter, Jean-Paul and Malpica, Maximiliano Emmanuel Ceron and Geissler, Mark Enrik and Runge, Josephine and Hasanovic, Jasmin and Selbmann, Anne and Geissler, Rona Berit and Krause-Jüttler, Grit and Kern, Alexander and Weitz, Jürgen and Distler, Marius and von Bechtolsheim, Felix and Dobroschke, Jakob and Oehme, Florian},
  title = {Comparison of learning curves and cross-over effects using articulating laparoscopic instruments versus standard laparoscopic instruments},
  journal = {Surgical Endoscopy},
  year = {2026},
  volume = {40},
  number = {8},
  pages = {6889--6901},
  doi = {10.1007/s00464-026-12977-1}
}
Kostenlos starten →