Robotic liver surgery: a global snapshot. Results from an international survey
Surgical Endoscopy · 2026
DOI: 10.1007/s00464-026-12582-2 ↗Kurz gefasst
Fachartikel in der Zeitschrift Surgical Endoscopy, 2026. Verfasst von Silvio Caringi und 9 weiteren Autor:innen. Beteiligte Einrichtung: Unit of Hepato-Biliary and Pancreatic Surgery, "F. Miulli" General Hospital, Acquaviva delle Fonti, 70021, Bari, Italy. silvio.caringi@ptvonline.it. Hauptthemen laut MEDLINE: Robotic Surgical Procedures, Hepatectomy. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Università degli Studi di Roma Tor Vergata.
Abstract (Originalsprache)
Background
Robotic liver surgery has gradually increased within the realm of minimally invasive hepatobiliary surgery; nevertheless, worldwide adoption rates, educational systems, and thought processes are various. Materials and methods An online worldwide survey was devised to collect data from hepatobiliary surgeons with experience or interests in robotic liver surgery. The design explores the use of robotic platforms, adoption rate, learning opportunities, learning curves, procedural options based on complexity, safety in perioperative phases, and limiting factors. Descriptive statistics are used to analyze the collected responses.
Results
The da Vinci platform is the most commonly used, while the new systems are still in the early adoption stages. Variability of use patterns has been identified. Structured learning, including simulation, proctoring, and learning at a second console, has been identified as essential to ensure safe adoption. The learning curve is a multi-step process that is dependent on procedure type, inherent surgical skills, and prior training. The laparoscopic, robotic, and open methods are considered to be relatively similar in low-complexity resections, while robotic, open, or a combination of robotic or open would be preferred for directing posterosuperior, major hepatectomy, as well as reconstruction cases, respectively.
Conclusion
Robotic liver surgery is gradually being adopted within the realm of hepatobiliary surgery, but has been unevenly distributed. Uniform models of training, organizational structure, and equal availability of systems are essential factors that define how such systems are expanded.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Unit of Hepato-Biliary and Pancreatic Surgery, "F. Miulli" General Hospital, Acquaviva delle Fonti, 70021, Bari, Italy. silvio.caringi@ptvonline.it.
- Department of Surgery, Università Degli Studi Roma "Tor Vergata", Via Montpellier1, 00133, Rome, Italy. silvio.caringi@ptvonline.it.
- Unit of Hepato-Biliary and Pancreatic Surgery, "F. Miulli" General Hospital, Acquaviva delle Fonti, 70021, Bari, Italy.
- Department of Medicine and Surgery, LUM University, 70010, Casamassima, Italy.
- Department of Surgery Sciences, Transplant and HPB Unit, University of Rome Tor Vergata, Rome, Italy.
Förderung
- Università degli Studi di Roma Tor Vergata
Zitieren
APA
Caringi, S., Delvecchio, A., Casella, A., Ferraro, V., Stasi, M., Tralli, N., Manzia, T. M., Tedeschi, M., Memeo, R., & Robotic Liver Network (2026). Robotic liver surgery: a global snapshot. Results from an international survey. Surgical Endoscopy. https://doi.org/10.1007/s00464-026-12582-2
Vancouver
Caringi S, Delvecchio A, Casella A, Ferraro V, Stasi M, Tralli N, et al. Robotic liver surgery: a global snapshot. Results from an international survey. Surgical Endoscopy. 2026. doi:10.1007/s00464-026-12582-2
BibTeX
@article{Caringi2026,
author = {Caringi, Silvio and Delvecchio, Antonella and Casella, Annachiara and Ferraro, Valentina and Stasi, Matteo and Tralli, Nunzio and Manzia, Tommaso Maria and Tedeschi, Michele and Memeo, Riccardo and Robotic Liver Network, Robotic Liver Network},
title = {Robotic liver surgery: a global snapshot. Results from an international survey},
journal = {Surgical Endoscopy},
year = {2026},
doi = {10.1007/s00464-026-12582-2}
}
EUVIMED