Diagnostic accuracy of C-reactive protein in detecting anastomotic leakage after minimally invasive rectal cancer surgery
Surgical Endoscopy · 2026
DOI: 10.1007/s00464-025-12428-3 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Surgical Endoscopy, 2026. Verfasst von David J Nijssen und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, Amsterdam UMC Location University of Amsterdam, Amsterdam, The Netherlands. Hauptthemen laut MEDLINE: Anastomotic Leak, Rectal Neoplasms, C-Reactive Protein, Proctectomy. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 31 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: C-reactive protein's (CRP) diagnostic utility for early detection of anastomotic leakage is based on heterogeneous patient groups, including different pathologies and surgical approaches, without accounting for the presence of faecal diversion. This study assessed the diagnostic accuracy of CRP in detecting anastomotic leakage after minimally invasive total mesorectal excision (TME) for rectal cancer, stratified by the presence or absence of a primary diverting stoma. METHODS: Patients from 11 high-volume centers in the Netherlands who underwent minimally invasive TME for rectal cancer between 2015 and 2021 were included. CRP levels were analyzed from postoperative days 1-4, and diagnostic accuracy was assessed using receiver operating characteristic analysis. Subgroup analyses were performed for patients with and without a primary diverting stoma. RESULTS: A total of 1418 patients were included, with anastomotic leakage occurring in 232 (16.4%). In patients without a stoma, the highest diagnostic accuracy was on day 4 at a cut-off of 104.5 mg/L, with sensitivity of 84.1%, specificity of 71.1%, PPV of 38.1%, and NPV of 95.5% (AUC = 0.83, P < 0.001). In patients with a stoma, diagnostic accuracy was lower, with maximum performance at a cut-off of 132.5 mg/L on day 4 (sensitivity 57.6%, specificity 78.7%, PPV 36.5%, NPV 89.7%, AUC = 0.71, P < 0.001). The difference in AUC was significant (P = 0.018). CONCLUSION: CRP has poor diagnostic accuracy for detecting anastomotic leakage in patients with a primary diverting stoma after minimally invasive rectal cancer surgery. Additional diagnostic tests should be considered for this group to allow for early detection of anastomotic leaks.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Surgery, Amsterdam UMC Location University of Amsterdam, Amsterdam, The Netherlands.
- Cancer Treatment and Quality of Life, Cancer Center Amsterdam, Amsterdam, The Netherlands.
- Department of Surgery, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.
- Department of Surgery, Meander Medical Center, Amersfoort, The Netherlands.
- Amsterdam Gastroenterology Endocrinology & Metabolism, Amsterdam, The Netherlands.
- Department of Surgery, Amsterdam UMC Location University of Amsterdam, Amsterdam, The Netherlands. r.hompes@amsterdamumc.nl.
ORCID-Profile: Mark Broekman
Zitieren
APA
Nijssen, D. J., Broekman, M., Rensink, F., Stuart, G., Geitenbeek, R. T. J., Stael, J., van Dieren, S., Bemelman, W. A., Tuynman, J., Consten, E. C. J., Hompes, R., Laméris, W., & Dutch MIRECA Collaborative Group (2026). Diagnostic accuracy of C-reactive protein in detecting anastomotic leakage after minimally invasive rectal cancer surgery. Surgical Endoscopy. https://doi.org/10.1007/s00464-025-12428-3
Vancouver
Nijssen DJ, Broekman M, Rensink F, Stuart G, Geitenbeek RTJ, Stael J, et al. Diagnostic accuracy of C-reactive protein in detecting anastomotic leakage after minimally invasive rectal cancer surgery. Surgical Endoscopy. 2026. doi:10.1007/s00464-025-12428-3
BibTeX
@article{Nijssen2026,
author = {Nijssen, David J and Broekman, Mark and Rensink, Franny and Stuart, Gijs and Geitenbeek, Ritch T J and Stael, Joost and van Dieren, Susan and Bemelman, Willem A and Tuynman, Jurriaan and Consten, Esther C J and Hompes, Roel and Laméris, Wytze and Dutch MIRECA Collaborative Group, Dutch MIRECA Collaborative Group},
title = {Diagnostic accuracy of C-reactive protein in detecting anastomotic leakage after minimally invasive rectal cancer surgery},
journal = {Surgical Endoscopy},
year = {2026},
doi = {10.1007/s00464-025-12428-3}
}
EUVIMED