EUVIMEDEUVIMED entdecken
Video/Audio

Robotic esophageal reconstruction with a diagonal stapling technique: technical description and early outcomes from a single-center series

Yuki Ushimaru, Kazuyoshi Yamamoto, Ryohei Kawabata, Yoshitomo Yanagimoto, Kazuki Odagiri, Tomohira Takeoka, Yasunori Masuike, Kei Yamamoto, Norihiro Matsuura, Takahito Sugase, Takashi Kanemura, Ryota Mori und 11 weitere

Surgical Endoscopy · 2025

DOI: 10.1007/s00464-025-12366-0 ↗

Kurz gefasst

Video/Audio in der Zeitschrift Surgical Endoscopy, 2025. Verfasst von Yuki Ushimaru und 22 weiteren Autor:innen. Beteiligte Einrichtung: Department of Gastroenterological Surgery, Osaka International Cancer Institute, 3-1-69 Otemae Chuoku, Osaka, Japan. yuki.ushimaru@oici.jp. Hauptthemen laut MEDLINE: Robotic Surgical Procedures, Surgical Stapling, Gastrectomy, Esophagoplasty. Die Arbeit nennt 31 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Esophageal reconstruction after total or proximal gastrectomy is technically demanding. Robotic platforms provide enhanced dexterity, yet anastomotic protocols vary widely. We developed a unified, geometry-driven robotic technique-applicable to both total and proximal gastrectomy-that creates a wide V-shaped anastomosis by extending and rotating a right-anterior esophageal flap to maximize perfusion and minimize axial tension. METHODS: Between March 2021 and May 2025, 41 patients underwent robotic gastrectomy using our "diagonal V-geometry" reconstruction: 18 proximal gastrectomies with esophagogastrostomy and 23 total gastrectomies with esophagojejunostomy. A multi-arm surgical robot with 3D visualization and articulating instruments was used. The muscularis was divided directly; the mucosa was incised over a nasogastric tube to avoid contralateral injury. Traction sutures rotated the flap posteriorly, widening the staple line interface. A powered linear stapler created a 40-45-mm V-shaped anastomosis to either the gastric remnant or Roux limb. The enterotomy was closed with a 60-mm staple line. In proximal gastrectomy, a partial Toupet fundoplication was added. Leak tests confirmed integrity. Barbed sutures secured fixation. RESULTS: Median age was 73 years (proximal) and 77 years (total); median BMI was 21.6 and 21.2 kg/m2. D2 lymphadenectomy was performed in most patients (88.9% in PG; 100% in TG). Median operative time was 428 min (proximal) and 400 min (total). Blood loss was minimal (median 0 mL). One non-anastomotic complication occurred (5.6%) in the proximal group; none in the total group. Critically, no anastomotic leaks, strictures, or reoperations occurred. Imaging confirmed wide lumens; patients resumed oral intake without dysphagia. Three-month follow-up showed no reflux. CONCLUSIONS: Our unified robotic diagonal V-geometry technique yielded zero leaks or strictures in 41 gastrectomies. By rotating the right-anterior flap to create a broad V-shaped staple line, perfusion is preserved and tension minimized. Larger multicenter studies are needed to confirm these promising outcomes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Robotic Surgical ProceduresSurgical StaplingGastrectomyEsophagoplastyEsophagusHumansAgedMaleFemaleAnastomosis, SurgicalMiddle AgedTreatment OutcomeStomach NeoplasmsAged, 80 and overOperative TimeRetrospective Studies

Stichwörter der Autor:innen

Diagonal staplingEsophageal anastomosisEsophagogastrostomyEsophagojejunostomyGastric cancerRobotic gastrectomy

Autor:innen und Institutionen

  • Department of Gastroenterological Surgery, Osaka International Cancer Institute, 3-1-69 Otemae Chuoku, Osaka, Japan. yuki.ushimaru@oici.jp.
  • Department of Gastroenterological Surgery, Sakai City Medical Center, Osaka, Japan. yuki.ushimaru@oici.jp.
  • Department of Gastroenterological Surgery, Osaka International Cancer Institute, 3-1-69 Otemae Chuoku, Osaka, Japan.
  • Department of Gastroenterological Surgery, Sakai City Medical Center, Osaka, Japan.
  • Department of Gastroenterological Surgery, Saiseikai Senri Hospital, Osaka, Japan.

Zitieren

APA

Ushimaru, Y., Yamamoto, K., Kawabata, R., Yanagimoto, Y., Odagiri, K., Takeoka, T., Masuike, Y., Yamamoto, K., Matsuura, N., Sugase, T., Kanemura, T., Mori, R., Kitakaze, M., Amisaki, M., Kubo, M., Fukuda, Y., Komatsu, H., Miyo, M., Sueda, T., …, & Miyata, H. (2025). Robotic esophageal reconstruction with a diagonal stapling technique: technical description and early outcomes from a single-center series. Surgical Endoscopy. https://doi.org/10.1007/s00464-025-12366-0

Vancouver

Ushimaru Y, Yamamoto K, Kawabata R, Yanagimoto Y, Odagiri K, Takeoka T, et al. Robotic esophageal reconstruction with a diagonal stapling technique: technical description and early outcomes from a single-center series. Surgical Endoscopy. 2025. doi:10.1007/s00464-025-12366-0

BibTeX
@article{Ushimaru2025,
  author = {Ushimaru, Yuki and Yamamoto, Kazuyoshi and Kawabata, Ryohei and Yanagimoto, Yoshitomo and Odagiri, Kazuki and Takeoka, Tomohira and Masuike, Yasunori and Yamamoto, Kei and Matsuura, Norihiro and Sugase, Takahito and Kanemura, Takashi and Mori, Ryota and Kitakaze, Masatoshi and Amisaki, Masataka and Kubo, Masahiko and Fukuda, Yasunari and Komatsu, Hisateru and Miyo, Masaaki and Sueda, Toshinori and Kagawa, Yoshinori and Gotoh, Kunihito and Kobayashi, Shogo and Miyata, Hiroshi},
  title = {Robotic esophageal reconstruction with a diagonal stapling technique: technical description and early outcomes from a single-center series},
  journal = {Surgical Endoscopy},
  year = {2025},
  doi = {10.1007/s00464-025-12366-0}
}
Kostenlos starten →