Evaluating pneumoperitoneum pressure in robotic liver surgery: a propensity-score matched analysis in a high-volume center in Scandinavia

Daisuke Fukumori iD, Christoph Tschuor, Takashi Hamada, Paul Suno Krohn, Stefan Burgdorf, Øivind Jans, Hans-Jørgen Frederiksen, Jens Hillingsø, Peter Nørgaard Larsen

Surgical Endoscopy · 2026

DOI: 10.1007/s00464-025-12283-2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Surgical Endoscopy, 2026. Verfasst von Daisuke Fukumori und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery and Transplantation, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Blegdamsvej 9, 2100, Copenhagen, Denmark. dais…. Hauptthemen laut MEDLINE: Robotic Surgical Procedures, Pneumoperitoneum, Artificial, Hepatectomy. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 55 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Copenhagen University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Minimally invasive liver surgery usually involves the use of standard pneumoperitoneal pressure (12–15 mmHg) and low central venous pressure (CVP) management to reduce intraoperative bleeding while hereby possibly increasing the risk for gas embolism. The purpose of this study is to evaluate the efficacy and safety of low pneumoperitoneum pressure (Low-PP: 10 mmHg) compared to standard pneumoperitoneum pressure (Standard-PP: 12 mmHg) in patients undergoing robotic liver surgery (RLS) without active CVP management.

Methods

A single-center retrospective cohort study was conducted from June 2019 to February 2024. Propensity-score matching analysis (1:1) was performed based on age, sex, BMI, ASA classification, diagnosis, and extent of resection (minor or major) for Low-PP group to Standard-PP group. The primary outcome were estimated blood loss (EBL), operating time (OT), length of stay (LOS), and complications (Clavien–Dindo classification).

Results

Before the propensity-score matching (PSM) analysis, the Low-PP group comprised 63 patients and the Standard-PP group comprised 130 patients. Following PSM analysis, each group comprised 62 patients. The pringle maneuver was performed significantly more frequently in the Low-PP group (87.1% vs 50.0%, p < 0.001). There were no statistically significant differences with regards EBL, OT, LOS, or overall/major complications between the two groups. Intraoperative anesthetic parameters were comparable, and no signs of gas embolism were observed in either group. In a subgroup analyis for minor and major resections, no statistically significant differences were observed in perioperative outcomes between the groups.

Conclusion

Our study did not find any statistically significant difference in perioperative outcomes of patients undergoing RLS at a pneumoperitoneal pressure of 10 mmHg versus 12 mmHg. We therefore conclude that performing RLS using a pneumoperitoneal pressure of 10 mmHg PP is feasible and safe. Randomized controlled trials are needed to further investigate the potential and benefit of this strategy.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Robotic Surgical ProceduresPneumoperitoneum, ArtificialHepatectomyHumansMaleFemalePropensity ScoreRetrospective StudiesMiddle AgedBlood Loss, SurgicalAgedOperative TimeLength of StayPressureHospitals, High-VolumePostoperative ComplicationsAdultEmbolism, Air

Stichwörter der Autor:innen

Laparoscopic liver surgeryLiver resectionPneumoperitoneal pressureRobotic liver surgery

Autor:innen und Institutionen

  • Department of Surgery and Transplantation, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Blegdamsvej 9, 2100, Copenhagen, Denmark. daisuke.fukumori@regionh.dk.
  • Department of Surgery and Transplantation, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Blegdamsvej 9, 2100, Copenhagen, Denmark.
  • Department of Anaesthesiology, Center for Cancer and Organ Diseases, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark.

ORCID-Profile: Daisuke Fukumori

Förderung

  • Copenhagen University

Zitieren

APA

Fukumori, D., Tschuor, C., Hamada, T., Krohn, P. S., Burgdorf, S., Jans, Ø., Frederiksen, H. J., Hillingsø, J., & Larsen, P. N. (2026). Evaluating pneumoperitoneum pressure in robotic liver surgery: a propensity-score matched analysis in a high-volume center in Scandinavia. Surgical Endoscopy. https://doi.org/10.1007/s00464-025-12283-2

Vancouver

Fukumori D, Tschuor C, Hamada T, Krohn PS, Burgdorf S, Jans Ø, et al. Evaluating pneumoperitoneum pressure in robotic liver surgery: a propensity-score matched analysis in a high-volume center in Scandinavia. Surgical Endoscopy. 2026. doi:10.1007/s00464-025-12283-2

BibTeX
@article{Fukumori2026,
  author = {Fukumori, Daisuke and Tschuor, Christoph and Hamada, Takashi and Krohn, Paul Suno and Burgdorf, Stefan and Jans, Øivind and Frederiksen, Hans-Jørgen and Hillingsø, Jens and Larsen, Peter Nørgaard},
  title = {Evaluating pneumoperitoneum pressure in robotic liver surgery: a propensity-score matched analysis in a high-volume center in Scandinavia},
  journal = {Surgical Endoscopy},
  year = {2026},
  doi = {10.1007/s00464-025-12283-2}
}
Kostenlos starten →