Comparison of laparoscopic performance using low-cost laparoscopy simulators versus state-of-the-art simulators: a multi-center prospective, randomized crossover trial
Surgical Endoscopy · 2025
DOI: 10.1007/s00464-025-11531-9 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Surgical Endoscopy, 2025. Verfasst von Mark Enrik Geissler und 14 weiteren Autor:innen. Beteiligte Einrichtung: Department of Visceral, Thoracic and Vascular Surgery, Faculty of Medicine, University Hospital Carl Gustav Carus, TUD Dresden University of Technolo…. Hauptthemen laut MEDLINE: Laparoscopy, Simulation Training, Clinical Competence. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Deutsche Forschungsgemeinschaft, Bundesministerium für Bildung und Forschung, Universitätsklinikum Carl Gustav Carus Dresden an der Technischen Universität Dresden.
Abstract (Originalsprache)
Introduction
Simulator training is an efficient method for the development of basic laparoscopic skills. We aimed to investigate if low-cost simulators are comparable to more expensive box trainers regarding surgeons usability, likability, and performance.
Methods
This multi-center, randomized crossover study included 16 medical students, seven abdominal surgeons, and seven urological surgeons. Participants performed four laparoscopic tasks (peg transfer, circle cutting, balloon resection, suture and knot) on both, a “Low cost trainer” (LCT) or a “high cost trainer” (HCT) in a randomized order. The primary endpoint was the subjective rating of both training simulators in terms of camera view, depth perception, movement of instruments, pricing, and usability for training. Secondary endpoints were force parameters, task completion time, surgical errors, and psychological workload.
Results
Participants rated the LCT better concerning view ( p < 0.001), depth perception ( p = 0.003), pricing ( p < 0.001), and usability for digital training ( p < 0.001), but worse in terms of instrument movement ( p = 0.004). Overall, the LCT was rated better than the HCT ( p = 0.015). Regarding force parameters, participants showed a significantly lower force exertion on the HCT during the peg transfer task ( p = 0.008). The force exertion in the other tasks were comparable between both trainers. Participants were significantly faster using the HCT during the peg transfer ( p = 0.049) and significantly slower in balloon resection ( p = 0.049) and suture and knot task ( p = 0.026). The assessment of the participants’ workload showed no differences.
Conclusion
The LCT was generally rated better than the HCT. The differences concerning force exertion and task completion time showed better results during peg transfer at the HCT but were generally inconclusive and without systemic advantage for either trainer. However, the LCT could be a promising and cost-effective augmentation for modern laparoscopic training. Graphical abstract
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Visceral, Thoracic and Vascular Surgery, Faculty of Medicine, University Hospital Carl Gustav Carus, TUD Dresden University of Technology, Fetscherstraße 74, 01307, Dresden, Germany.
- Department of Urology and Urosurgery, University Medical Centre Mannheim, University of Heidelberg, Mannheim, Germany.
- Division Intelligent Systems and Robotics in Urology, German Cancer Research Center (DKFZ), Heidelberg, Germany.
- DKFZ Hector Cancer Institute, University Medical Center Mannheim, Mannheim, Germany.
- Centre for Tactile Internet with Human-in-the-Loop (CeTI), TUD Dresden University of Technology, Fetscherstraße 74, 01307, Dresden, Germany.
- National Center for Tumor Diseases (NCT/UCC), Dresden, Germany.
ORCID-Profile: Felix von Bechtolsheim
Förderung
- Deutsche Forschungsgemeinschaft
- Bundesministerium für Bildung und Forschung
- Universitätsklinikum Carl Gustav Carus Dresden an der Technischen Universität Dresden
Zitieren
APA
Geissler, M. E., Bereuter, J. P., Geissler, R. B., Kowalewski, K. F., Egen, L., Haney, C., Schmidt, S., Fries, A., Buck, N., Weiß, J., Krause-Jüttler, G., Weitz, J., Distler, M., Oehme, F., & von Bechtolsheim, F. (2025). Comparison of laparoscopic performance using low-cost laparoscopy simulators versus state-of-the-art simulators: a multi-center prospective, randomized crossover trial. Surgical Endoscopy. https://doi.org/10.1007/s00464-025-11531-9
Vancouver
Geissler ME, Bereuter JP, Geissler RB, Kowalewski KF, Egen L, Haney C, et al. Comparison of laparoscopic performance using low-cost laparoscopy simulators versus state-of-the-art simulators: a multi-center prospective, randomized crossover trial. Surgical Endoscopy. 2025. doi:10.1007/s00464-025-11531-9
BibTeX
@article{Geissler2025,
author = {Geissler, Mark Enrik and Bereuter, Jean-Paul and Geissler, Rona Berit and Kowalewski, Karl-Friedrich and Egen, Luisa and Haney, Caelan and Schmidt, Sofia and Fries, Alexa and Buck, Nathalie and Weiß, Juliane and Krause-Jüttler, Grit and Weitz, Jürgen and Distler, Marius and Oehme, Florian and von Bechtolsheim, Felix},
title = {Comparison of laparoscopic performance using low-cost laparoscopy simulators versus state-of-the-art simulators: a multi-center prospective, randomized crossover trial},
journal = {Surgical Endoscopy},
year = {2025},
doi = {10.1007/s00464-025-11531-9}
}
EUVIMED