EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte StudieÄquivalenzstudie

The MESH-RTL Project for prevention of abdominal wound dehiscence (AWD) in high-risk patients: noninferiority, randomized controlled trial

Edgard Efrén Lozada Hernández iD, Eduardo Flores González iD, Jose Luis Chavarría Chavira iD, Bruno Hernandez Herrera iD, Cesar Gustavo Rojas Benítez iD, Luis Manuel García Bravo iD, Rodolfo Raul Sanchez Rosado iD, Ricardo Reynoso González iD, Mariana Gutiérrez Neri Perez, Maria Fernanda Reynoso Barroso, Javier Soria Rangel iD

Surgical Endoscopy · 2024-12 · 38 (12) · 7634-7646

DOI: 10.1007/s00464-024-11358-w ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift Surgical Endoscopy, online erschienen am 25.10.2024. Verfasst von Edgard Efrén Lozada Hernández und 10 weiteren Autor:innen. Beteiligte Einrichtung: General Surgery, Department of Diseases of the Digestive Tract, Servicios de salud del Instituto Mexicano del Seguro Social Para El Bienestar (IMSS-B…. Hauptthemen laut MEDLINE: Surgical Mesh, Surgical Wound Dehiscence. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 59 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To compare reinforced tension line (RTL) and mesh techniques in the onlay position for preventing abdominal wound dehiscence (AWD) in a noninferiority clinical trial. METHODS: Patients > 18 years old who underwent midline laparotomy and who were considered at high risk on the modified Rotterdam risk scale were included. The outcomes analyzed were the incidence of AWD and surgical site occurrence (SSO). RESULTS: 239 patients were included: 121 mesh group and 118 RTL group. Five (4.1%) of the 121 patients in the mesh group and 7 (5.9%) of the 118 patients in the RTL group presented with AWD (p = 0.56, RR = 0.69, 95% CI = 0.22-2.13) in the per-protocol analysis. The median time of presentation was 6 days. The 95% CI (-0.0567, 0.0231) for the difference in incidence between the two groups was entirely within the predefined noninferiority margin of 5%. The incidence of complications did not significantly differ between the two groups: the mesh group (27, 22.3%) and the RTL group (16, 12.8%) (p = 0.09, RR (95% CI) = 1.64 (0.93-2.89)). CONCLUSION: The use of the RTL technique for preventing AWD was not inferior to the use of mesh in the onlay position, nor did it increase the risk of complications. This study was registered on clinicaltrials.gov: Mesh-RTL Project (NCT04134455).

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Surgical MeshSurgical Wound DehiscenceAdultAgedFemaleHumansMaleMiddle AgedAbdominal Wound Closure TechniquesIncidenceLaparotomy

Stichwörter der Autor:innen

Abdominal wound dehiscenceMesh onlay positionNoninferiority clinical trialPreventionReinforced tension line

Autor:innen und Institutionen

  • General Surgery, Department of Diseases of the Digestive Tract, Servicios de salud del Instituto Mexicano del Seguro Social Para El Bienestar (IMSS-BIENESTAR) Hospital Regional de Alta Especialidad del Bajío, Colonia Qu…
  • General Surgery, Department of Diseases of the Digestive Tract, Servicios de Salud del Instituto Mexicano del Seguro Social Para El Bienestar (IMSS-BIENESTAR) Hospital Regional de Alta Especialidad del Bajío, León, Guan…
  • General Surgery, Civil Hospital Dr. Juan I Menchaca, Guadalajara, México.
  • General Surgery, Social Security Institute of the State of Mexico and Municipalities, Toluca, México.
  • General Surgery, Regional Hospital Dr. Valentin Gomez Farias, Institute for Social Security and Services for State Workers, Guadalajara, Mexico.
  • General Surgery, Department of Coloproctology, Mexican Social Security Institute, Veracruz, Mexico.

ORCID-Profile: Edgard Efrén Lozada Hernández, Eduardo Flores González, Jose Luis Chavarría Chavira, Bruno Hernandez Herrera, Cesar Gustavo Rojas Benítez, Luis Manuel García Bravo, Rodolfo Raul Sanchez Rosado, Ricardo Reynoso González, Javier Soria Rangel

Zitieren

APA

Lozada Hernández, E. E., Flores González, E., Chavarría Chavira, J. L., Hernandez Herrera, B., Rojas Benítez, C. G., García Bravo, L. M., Sanchez Rosado, R. R., Reynoso González, R., Gutiérrez Neri Perez, M., Reynoso Barroso, M. F., & Soria Rangel, J. (2024). The MESH-RTL Project for prevention of abdominal wound dehiscence (AWD) in high-risk patients: noninferiority, randomized controlled trial. Surgical Endoscopy, 38(12), 7634-7646. https://doi.org/10.1007/s00464-024-11358-w

Vancouver

Lozada Hernández EE, Flores González E, Chavarría Chavira JL, Hernandez Herrera B, Rojas Benítez CG, García Bravo LM, et al. The MESH-RTL Project for prevention of abdominal wound dehiscence (AWD) in high-risk patients: noninferiority, randomized controlled trial. Surgical Endoscopy. 2024;38(12):7634-7646. doi:10.1007/s00464-024-11358-w

BibTeX
@article{LozadaHernndez2024,
  author = {Lozada Hernández, Edgard Efrén and Flores González, Eduardo and Chavarría Chavira, Jose Luis and Hernandez Herrera, Bruno and Rojas Benítez, Cesar Gustavo and García Bravo, Luis Manuel and Sanchez Rosado, Rodolfo Raul and Reynoso González, Ricardo and Gutiérrez Neri Perez, Mariana and Reynoso Barroso, Maria Fernanda and Soria Rangel, Javier},
  title = {The MESH-RTL Project for prevention of abdominal wound dehiscence (AWD) in high-risk patients: noninferiority, randomized controlled trial},
  journal = {Surgical Endoscopy},
  year = {2024},
  volume = {38},
  number = {12},
  pages = {7634--7646},
  doi = {10.1007/s00464-024-11358-w}
}
Kostenlos starten →