EUVIMEDEUVIMED entdecken
Systematische ÜbersichtVergleichsstudieNetzwerk-Metaanalyse

Single-port versus multi-port laparoscopic and robotic inguinal hernia repair: a systematic review and network meta-analysis

Theethawat Thanawiboonchai iD, Amanda Cyntia Lima Fonseca Rodrigues, Alba Zevallos, Fatemeh Shojaeian, Brett Colton Parker, Alisa Mae Coker, Hao Deng, Gina Lynn Adrales

Surgical Endoscopy · 2025

DOI: 10.1007/s00464-024-11321-9 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift Surgical Endoscopy, 2025. Verfasst von Theethawat Thanawiboonchai und 7 weiteren Autor:innen. Beteiligte Einrichtung: Division of Minimally Invasive Surgery, Department of Surgery, The Johns Hopkins School of Medicine, Baltimore, MD, USA. Hauptthemen laut MEDLINE: Hernia, Inguinal, Herniorrhaphy, Laparoscopy, Robotic Surgical Procedures. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 59 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: The evolution of minimally invasive surgery has transformed inguinal hernia repair (IHR). The innovative single-port technique reduces the number of surgical incisions. However, the benefits of single-port IHR remain controversial. Our systematic review and network meta-analysis assess the efficacy and clinical outcomes of single-port laparoscopic inguinal hernia repair (SPL-IHR), multi-port laparoscopic inguinal hernia repair (MPL-IHR), single-port robotic inguinal hernia repair (SPR-IHR), and multi-port robotic inguinal hernia repair (MPR-IHR). METHODS: A comprehensive search was conducted in PubMed, EMBASE, Cochrane, and Ovid for articles published before January 2024, focusing on complication rates, recurrence, seroma, hematoma, operative time, post-operative pain, and cosmetic outcomes of laparoscopic or robotic IHR. Both extraperitoneal (TEP) and transabdominal (TAPP) approaches were analyzed using MetaInsight. MPL-TAPP was used as the standard for comparison. RESULTS: Thirty-seven studies, including 5,038 patients, 36.92% (1,860 patients) underwent MPL-TEP, 23.64% (1,191 patients) SPL-TEP, 22.23% (1,120 patients) MPR-TAPP, 10.08% (508 patients) MPL-TAPP, 5.40% (272 patients) SPL-TAPP, and 1.73% (87 patients) SPR-TAPP. There were no significant differences in the rates of post-operative complications, hernia recurrence, hematoma, or seroma among the techniques when compared to MPL-TAPP. For secondary outcomes, MPR-TAPP significantly increased the operative time for unilateral hernia repair by a mean difference (MD) of 10.60 min [95% CI: 2.16-19.04]. Conversely, for bilateral hernia repair, there was no significant difference. Post-operative pain was significantly higher for MPL-TEP and SPL-TEP, with MDs of 1.44 [95% CI: 0.43 to 2.44] and 1.22 [95% CI: 0.18 to 2.26], respectively. SPL-TEP was significantly favored in cosmetic outcomes over MPL-TEP, with an MD of 0.65 [95% CI: 0.07 to 1.24]. CONCLUSION: In our network meta-analysis, the risk of post-operative complications, including recurrence, hematoma, and seroma, does not significantly vary among single-port and multi-port laparoscopic or robotic techniques. This suggests that surgical technique selection can rely on surgeon expertise and resource availability, without compromising outcomes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Hernia, InguinalHerniorrhaphyLaparoscopyRobotic Surgical ProceduresHumansOperative TimePostoperative PainPostoperative ComplicationsRecurrenceTreatment Outcome

Stichwörter der Autor:innen

Inguinal hernia repairRobotic inguinal hernia repairSingle port surgerySingle incision surgeryTotally Extra Peritoneal (TEP)Trans-Abdominal PrePeritoneal (TAPP)

Autor:innen und Institutionen

  • Division of Minimally Invasive Surgery, Department of Surgery, The Johns Hopkins School of Medicine, Baltimore, MD, USA.
  • Department of Neurology, University of North Carolina at Chapel Hill, Chapel Hill, NC, USA.
  • Department of Surgery, Northwest Hospital, Randallstown, MD, USA.
  • Department of Medicine, Universidad Científica del Sur, Lima, Peru.
  • Department of Anesthesia, Critical Care and Pain Medicine, Massachusetts General Hospital and, Harvard Medical School, Boston, MA, USA.
  • Division of Minimally Invasive Surgery, Department of Surgery, The Johns Hopkins School of Medicine, Baltimore, MD, USA. gadrale1@jhmi.edu.

ORCID-Profile: Theethawat Thanawiboonchai

Zitieren

APA

Thanawiboonchai, T., Cyntia Lima Fonseca Rodrigues, A., Zevallos, A., Shojaeian, F., Parker, B. C., Coker, A. M., Deng, H., & Adrales, G. L. (2025). Single-port versus multi-port laparoscopic and robotic inguinal hernia repair: a systematic review and network meta-analysis. Surgical Endoscopy. https://doi.org/10.1007/s00464-024-11321-9

Vancouver

Thanawiboonchai T, Cyntia Lima Fonseca Rodrigues A, Zevallos A, Shojaeian F, Parker BC, Coker AM, et al. Single-port versus multi-port laparoscopic and robotic inguinal hernia repair: a systematic review and network meta-analysis. Surgical Endoscopy. 2025. doi:10.1007/s00464-024-11321-9

BibTeX
@article{Thanawiboonchai2025,
  author = {Thanawiboonchai, Theethawat and Cyntia Lima Fonseca Rodrigues, Amanda and Zevallos, Alba and Shojaeian, Fatemeh and Parker, Brett Colton and Coker, Alisa Mae and Deng, Hao and Adrales, Gina Lynn},
  title = {Single-port versus multi-port laparoscopic and robotic inguinal hernia repair: a systematic review and network meta-analysis},
  journal = {Surgical Endoscopy},
  year = {2025},
  doi = {10.1007/s00464-024-11321-9}
}
Kostenlos starten →