Rectal stenosis after circular mechanical anastomosis; the influence of stapler size
Surgical Endoscopy · 2024
DOI: 10.1007/s00464-024-11306-8 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Surgical Endoscopy, 2024. Verfasst von Núria Llorach-Perucho und 5 weiteren Autor:innen. Beteiligte Einrichtung: Coloproctology Unit, General and Digestive Surgery Service, Parc Tauli University Hospital, Sabadell. Institut d'investigació i innovació Parc Tauli …. Hauptthemen laut MEDLINE: Anastomosis, Surgical, Surgical Staplers, Rectal Neoplasms, Postoperative Complications. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universitat Autònoma de Barcelona.
Abstract (Originalsprache)
Background
The incidence of benign anastomotic stenosis (BAS) after radical surgery for rectal cancer ranges from 2 to 30%. There are few data regarding the factors related to its occurrence. One of these factors is the diameter of the circular mechanical staplers (CMS) used.
Methods
Observational study with prospective data recording of consecutive patients with non-disseminated rectal cancer operated on at two hospitals with special dedication to rectal cancer. Patients underwent low anterior resection (LAR) of the rectum with colorectal anastomosis created using CMS of diameters of either 28–29 or 31–33 mm. The primary endpoint was BAS. Secondary variables were demographic and patient-dependent data, and preoperative, intraoperative, immediate postoperative and mid-term data. The incidence of BAS was compared in the groups in which the different stapler diameters were used.
Results
Between 2012 and 2022, 239 patients were included. BAS was recorded in 39 (16.3%). In the analysis of factors related to its occurrence, the only significant variable was stapler diameter ( p = 0.002, 95% CI 7.27–23.53), since rates of BAS were lower in the 31–33 mm group. Similarly, in the logistic regression analysis, stapler size was not associated with postoperative complications or anastomotic dehiscence (OR 3.5, 95% CI 1.2–10.5). Comparing stapler groups, BAS was detected in 35 of 165 patients (21%) in the 28–29 mm group but in only four out of 74 (5.6%) in the 31–33 mm group ( p = 0.002, 95% CI 7.27–23.53). Ileostomy closure took longer and was less frequent in the 28–29 mm group.
Conclusions
The rate of BAS after LAR was not negligible, since it was recorded in 39 of 239 patients (16.3%). The use of a 31–33 mm CMS was associated with a lower incidence of BAS. Therefore, the use of larger staplers is tentatively recommended; however, clinical trials are now required to confirm these results. Graphical abstract
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Coloproctology Unit, General and Digestive Surgery Service, Parc Tauli University Hospital, Sabadell. Institut d'investigació i innovació Parc Tauli I3PT-CERCA, Sabadell (Barcelona), Spain.
- Department of Surgery, Universitat Autònoma de Barcelona, 08208, Sabadell (Barcelona), Spain.
- Coloproctology Unit, Consorci Sanitari de Terrassa, Terrassa (Barcelona), Spain.
- Institut d'investigació I Innovació Parc Tauli I3PT-CERCA, Sabadell (Barcelona), Spain.
- Coloproctology Unit, General and Digestive Surgery Service, Parc Tauli University Hospital, Sabadell. Institut d'investigació i innovació Parc Tauli I3PT-CERCA, Sabadell (Barcelona), Spain. Javier.Serra@uab.cat.
- Department of Surgery, Universitat Autònoma de Barcelona, 08208, Sabadell (Barcelona), Spain. Javier.Serra@uab.cat.
ORCID-Profile: Xavier Serra-Aracil
Förderung
- Universitat Autònoma de Barcelona
Zitieren
APA
Llorach-Perucho, N., Cayetano-Paniagua, L., Esteve-Monja, P., Garcia-Nalda, A., Bargalló, J., & Serra-Aracil, X. (2024). Rectal stenosis after circular mechanical anastomosis; the influence of stapler size. Surgical Endoscopy. https://doi.org/10.1007/s00464-024-11306-8
Vancouver
Llorach-Perucho N, Cayetano-Paniagua L, Esteve-Monja P, Garcia-Nalda A, Bargalló J, Serra-Aracil X. Rectal stenosis after circular mechanical anastomosis; the influence of stapler size. Surgical Endoscopy. 2024. doi:10.1007/s00464-024-11306-8
BibTeX
@article{LlorachPerucho2024,
author = {Llorach-Perucho, Núria and Cayetano-Paniagua, Ladislao and Esteve-Monja, Pau and Garcia-Nalda, Albert and Bargalló, Josep and Serra-Aracil, Xavier},
title = {Rectal stenosis after circular mechanical anastomosis; the influence of stapler size},
journal = {Surgical Endoscopy},
year = {2024},
doi = {10.1007/s00464-024-11306-8}
}