EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

A multi-nozzle nebuliser does not improve tissue drug delivery during PIPAC

Yaroslaw Sautkin, Juergen Weinreich, Marc André Reymond

Surgical Endoscopy · 2024

DOI: 10.1007/s00464-024-11172-4 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Surgical Endoscopy, 2024. Verfasst von Yaroslaw Sautkin und 2 weiteren Autor:innen. Beteiligte Einrichtung: National Center for Pleura and Peritoneum, University Hospital Tübingen, Hoppe-Seyler-Straße 3, 72076, Tübingen, Germany. Yaroslav_sautkin@gmx.de. Hauptthemen laut MEDLINE: Nebulizers and Vaporizers, Aerosols, Doxorubicin, Cisplatin. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Capnopharm GmbH, Tübingen, Germany, Universitätsklinikum Tübingen.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Multi-nozzle nebulisers for pressurised intraperitoneal aerosol chemotherapy (PIPAC) are implemented in clinical practice to improve the homogeneity of tissue drug delivery. Nonetheless, the advantages of such devices over one-nozzle nebulisers have not been demonstrated thus far. In this study, we compared the performance of multi- and one-nozzle nebulisers by conducting physical and ex vivo pharmacological experiments.

Methods

The one-nozzle nebuliser Capnopen® and the multi-nozzle nebuliser were the subjects of this study. In physical experiments, the aerosol droplet size was measured by laser diffraction spectroscopy. Spatial spray patterns were depicted on blotting paper. Pharmacological experiments were performed on the enhanced inverted bovine urinary bladder model, demonstrating real-time tissue drug delivery, aerosol sedimentation and homogeneity of doxorubicin and cisplatin tissue distribution.

Results

The multi-nozzle nebuliser had a sixfold greater aerosolisation flow and a threefold greater angle of aerosolisation than Capnopen®. The aerosol particle size and distribution range were higher than that of Capnopen®. Spray patterns on blotting paper were more extensive with the multi-nozzle nebuliser. Real-time tissue drug delivery with the multi-nozzle nebuliser was over 100 ml within 1 min, and the aerosol sedimentation was 48.9% ± 21.2%, which was not significantly different from that of Capnopen®. The doxorubicin and cisplatin tissue concentrations were greater with Capnopen®. Although there was no significant difference in the homogeneity of doxorubicin distribution between the two devices, the homogeneity of cisplatin distribution was significantly higher with Capnopen®.

Conclusion

The multi-nozzle PIPAC nebuliser did not fulfil expectations. Even though the surface spray patterns were broader with the multi-nozzle nebuliser, the tissue drug homogeneity and concentration were greater with Capnopen®. Graphical Abstract

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Nebulizers and VaporizersAerosolsDoxorubicinCisplatinDrug Delivery SystemsAnimalsCattleAntineoplastic AgentsEquipment DesignUrinary BladderParticle SizeTissue DistributionAdministration, Inhalation

Stichwörter der Autor:innen

Intraperitoneal drug deliveryNebuliserPeritoneal metastasisPeritoneumPressurised intraperitoneal aerosol chemotherapy—PIPAC

Substanzen

AerosolsDoxorubicinCisplatinAntineoplastic Agents

Autor:innen und Institutionen

  • National Center for Pleura and Peritoneum, University Hospital Tübingen, Hoppe-Seyler-Straße 3, 72076, Tübingen, Germany. Yaroslav_sautkin@gmx.de.
  • Department of General, Visceral and Transplant Surgery, University Hospital Tübingen, Hoppe-Seyler-Straße 3, 72076, Tübingen, Germany. Yaroslav_sautkin@gmx.de.
  • National Center for Pleura and Peritoneum, University Hospital Tübingen, Hoppe-Seyler-Straße 3, 72076, Tübingen, Germany.
  • Department of General, Visceral and Transplant Surgery, University Hospital Tübingen, Hoppe-Seyler-Straße 3, 72076, Tübingen, Germany.

Förderung

  • Capnopharm GmbH, Tübingen, Germany
  • Universitätsklinikum Tübingen

Zitieren

APA

Sautkin, Y., Weinreich, J., & Reymond, M. A. (2024). A multi-nozzle nebuliser does not improve tissue drug delivery during PIPAC. Surgical Endoscopy. https://doi.org/10.1007/s00464-024-11172-4

Vancouver

Sautkin Y, Weinreich J, Reymond MA. A multi-nozzle nebuliser does not improve tissue drug delivery during PIPAC. Surgical Endoscopy. 2024. doi:10.1007/s00464-024-11172-4

BibTeX
@article{Sautkin2024,
  author = {Sautkin, Yaroslaw and Weinreich, Juergen and Reymond, Marc André},
  title = {A multi-nozzle nebuliser does not improve tissue drug delivery during PIPAC},
  journal = {Surgical Endoscopy},
  year = {2024},
  doi = {10.1007/s00464-024-11172-4}
}
Kostenlos starten →