EUVIMEDEUVIMED entdecken
Scoping ReviewOpen Access · CC BY 4.0

Da Vinci single-port robotic system current application and future perspective in general surgery: A scoping review

Francesco Celotto iD, Niccolò Ramacciotti, Alberto Mangano, Giacomo Danieli, Federico Pinto, Paula Lopez, Alvaro Ducas, Jessica Cassiani, Luca Morelli, Gaya Spolverato, Francesco Maria Bianco

Surgical Endoscopy · 2024-09 · 38 (9) · 4814-4830

DOI: 10.1007/s00464-024-11126-w ↗

Kurz gefasst

Scoping Review in der Zeitschrift Surgical Endoscopy, online erschienen am 07.08.2024. Verfasst von Francesco Celotto und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgical, Oncological and Gastroenterological Sciences, University of Padova, Padova, Italy. francesco.celotto@unipd.it. Hauptthemen laut MEDLINE: Robotic Surgical Procedures. Die Arbeit wurde bisher 102-mal zitiert (Crossref) und nennt 87 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Università degli Studi di Padova.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The da Vinci Single-Port Robot System (DVSP) allows three robotic instruments and an articulated scope to be inserted through a single small incision. It received FDA approval in 2014 and was first introduced in 2018. The aim of this new system was to overcome the limitations of single-incision laparoscopic and robotic surgery. Since then, it has been approved for use only for urologic and transoral surgeries in some countries. It has been used as part of experimental protocols in general surgery.

Objective

By obtaining the CE mark at the end of January 2024, DVSP will soon enter the European market. This review aims to comprehensively describe the applications of DVSP in general surgery.

Design

A search of PubMed, Embase, and Ebsco databases up to March 2024 was conducted, with registration in PROSPERO (CRD42024536430), following the preferred reporting items for Systematic reviews and Meta-analyses for scoping review (PRISMA-Scr) guidelines. All the studies about the use of DVSP in general surgery were included.

Results

Fifty-six studies were included. The following surgical areas of use were identified: transabdominal and transanal colorectal, cholecystectomy, abdominal wall repair, upper gastroesophageal tract, liver, pancreas, breast, and thyroid surgery. The reported surgical and short-term outcomes are promising; a wide range of procedures have been performed safely. Some groups have found advantages, such as faster discharge, shorter operative time, and less postoperative pain compared to multiport robotic surgery.

Conclusion

Five years after its initial clinical applications, the use of the DVSP in general surgery procedures has demonstrated feasibility and safety. Hernia repair, cholecystectomy, and colorectal surgery emerge as the most frequently conducted interventions with this robotic system. Nevertheless, there is anticipation for further studies with larger sample sizes and extended follow-up periods to provide more comprehensive insights and data on the long-term outcomes, including the incidence of incisional hernia. Graphical Abstract

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Robotic Surgical ProceduresHumansGeneral SurgeryLaparoscopy

Stichwörter der Autor:innen

General surgeryRoboticSingle port

Autor:innen und Institutionen

  • Department of Surgical, Oncological and Gastroenterological Sciences, University of Padova, Padova, Italy. francesco.celotto@unipd.it.
  • Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, Pisa, Italy.
  • Division of General, Minimally Invasive, and Robotic Surgery, Department of Surgery, University of Illinois at Chicago, Chicago, IL, USA.
  • Unit of Biostatistics, Epidemiology and Public Health (UBEP), Department of Cardio-Thoraco-Vascular Sciences and Public Health, University of Padua, Padova, Italy.
  • Department of Surgical, Oncological and Gastroenterological Sciences, University of Padova, Padova, Italy.

ORCID-Profile: Francesco Celotto

Förderung

  • Università degli Studi di Padova

Zitieren

APA

Celotto, F., Ramacciotti, N., Mangano, A., Danieli, G., Pinto, F., Lopez, P., Ducas, A., Cassiani, J., Morelli, L., Spolverato, G., & Bianco, F. M. (2024). Da Vinci single-port robotic system current application and future perspective in general surgery: A scoping review. Surgical Endoscopy, 38(9), 4814-4830. https://doi.org/10.1007/s00464-024-11126-w

Vancouver

Celotto F, Ramacciotti N, Mangano A, Danieli G, Pinto F, Lopez P, et al. Da Vinci single-port robotic system current application and future perspective in general surgery: A scoping review. Surgical Endoscopy. 2024;38(9):4814-4830. doi:10.1007/s00464-024-11126-w

BibTeX
@article{Celotto2024,
  author = {Celotto, Francesco and Ramacciotti, Niccolò and Mangano, Alberto and Danieli, Giacomo and Pinto, Federico and Lopez, Paula and Ducas, Alvaro and Cassiani, Jessica and Morelli, Luca and Spolverato, Gaya and Bianco, Francesco Maria},
  title = {Da Vinci single-port robotic system current application and future perspective in general surgery: A scoping review},
  journal = {Surgical Endoscopy},
  year = {2024},
  volume = {38},
  number = {9},
  pages = {4814--4830},
  doi = {10.1007/s00464-024-11126-w}
}
Kostenlos starten →