EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Real-time quantification of laser speckle contrast imaging during intestinal laparoscopic surgery: successful demonstration in a porcine intestinal ischemia model

J Tim Hoffman iD, Danique J I Heuvelings, Tim van Zutphen, Laurents P S Stassen, Schelto Kruijff, E Christiaan Boerma, Nicole D Bouvy, Wido T Heeman, Mahdi Al-Taher

Surgical Endoscopy · 2024

DOI: 10.1007/s00464-024-11076-3 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Surgical Endoscopy, 2024. Verfasst von J Tim Hoffman und 8 weiteren Autor:innen. Beteiligte Einrichtung: Faculty Campus Fryslân, University of Groningen, Wirdumerdijk 34, 8911 CE, Leeuwarden, The Netherlands. tim.hoffman@limis.com. Hauptthemen laut MEDLINE: Laparoscopy, Ischemia, Laser Speckle Contrast Imaging. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Anastomotic leakage (AL) is a dreaded complication following colorectal cancer surgery, impacting patient outcome and leads to increasing healthcare consumption as well as economic burden. Bowel perfusion is a significant modifiable factor for anastomotic healing and thus crucial for reducing AL.

Aims

The study aimed to calculate a cut-off value for quantified laser speckle perfusion units (LSPUs) in order to differentiate between ischemic and well-perfused tissue and to assess inter-observer reliability.

Methods

LSCI was performed using a porcine ischemic small bowel loop model with the PerfusiX-Imaging® system. An ischemic area, a well-perfused area, and watershed areas, were selected based on the LSCI colormap. Subsequently, local capillary lactate (LCL) levels were measured. A logarithmic curve estimation tested the correlation between LSPU and LCL levels. A cut-off value for LSPU and lactate was calculated, based on anatomically ischemic and well-perfused tissue. Inter-observer variability analysis was performed with 10 observers.

Results

Directly after ligation of the mesenteric arteries, differences in LSPU values between ischemic and well-perfused tissue were significant ( p < 0.001) and increased significantly throughout all following measurements. LCL levels were significantly different ( p < 0.001) at both 60 and 120 min. Logarithmic curve estimation showed an R 2 value of 0.56 between LSPU and LCL values. A LSPU cut-off value was determined at 69, with a sensitivity of 0.94 and specificity of 0.87. A LCL cut-off value of 3.8 mmol/L was found, with a sensitivity and specificity of 0.97 and 1.0, respectively. There was no difference in assessment between experienced and unexperienced observers. Cohen’s Kappa values were moderate to good (0.52–0.66).

Conclusion

Real-time quantification of LSPUs may be a feasible intraoperative method to assess tissue perfusion and a cut-off value could be determined with high sensitivity and specificity. Inter-observer variability was moderate to good, irrespective of prior experience with the technique.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

LaparoscopyIschemiaLaser Speckle Contrast ImagingAnimalsSwineAnastomotic LeakDisease Models, AnimalIntestine, SmallObserver VariationReproducibility of ResultsLactic Acid

Stichwörter der Autor:innen

Anastomotic leakageImage-guided surgeryLaparoscopic surgeryLaser speckle contrast imagingPerfusion assessment

Substanzen

Lactic Acid

Autor:innen und Institutionen

  • Faculty Campus Fryslân, University of Groningen, Wirdumerdijk 34, 8911 CE, Leeuwarden, The Netherlands. tim.hoffman@limis.com.
  • University Medical Centre Groningen, Optical Molecular Imaging Groningen, Hanzeplein 1, 9713 GZ, Groningen, The Netherlands. tim.hoffman@limis.com.
  • Department of Surgery, Medical Centre Leeuwarden, Henri Dunantweg 2, 8934 AD, Leeuwarden, The Netherlands. tim.hoffman@limis.com.
  • LIMIS Development, Henri Dunantweg 2, 8934 AD, Leeuwarden, The Netherlands. tim.hoffman@limis.com.
  • NUTRIM, Research Institute of Nutrition and Translational Research in Metabolism, Maastricht University, Universiteitssingel 50, 6229 ER, Maastricht, The Netherlands.
  • Department of Surgery, Maastricht University Medical Centre+, P. Debyelaan 25, 6229 HX, Maastricht, The Netherlands.

ORCID-Profile: J Tim Hoffman

Zitieren

APA

Hoffman, J. T., Heuvelings, D. J. I., van Zutphen, T., Stassen, L. P. S., Kruijff, S., Boerma, E. C., Bouvy, N. D., Heeman, W. T., & Al-Taher, M. (2024). Real-time quantification of laser speckle contrast imaging during intestinal laparoscopic surgery: successful demonstration in a porcine intestinal ischemia model. Surgical Endoscopy. https://doi.org/10.1007/s00464-024-11076-3

Vancouver

Hoffman JT, Heuvelings DJI, van Zutphen T, Stassen LPS, Kruijff S, Boerma EC, et al. Real-time quantification of laser speckle contrast imaging during intestinal laparoscopic surgery: successful demonstration in a porcine intestinal ischemia model. Surgical Endoscopy. 2024. doi:10.1007/s00464-024-11076-3

BibTeX
@article{Hoffman2024,
  author = {Hoffman, J Tim and Heuvelings, Danique J I and van Zutphen, Tim and Stassen, Laurents P S and Kruijff, Schelto and Boerma, E Christiaan and Bouvy, Nicole D and Heeman, Wido T and Al-Taher, Mahdi},
  title = {Real-time quantification of laser speckle contrast imaging during intestinal laparoscopic surgery: successful demonstration in a porcine intestinal ischemia model},
  journal = {Surgical Endoscopy},
  year = {2024},
  doi = {10.1007/s00464-024-11076-3}
}
Kostenlos starten →