EUVIMEDEUVIMED entdecken
Validierungsstudie

Implementation of artificial intelligence-based computer vision model in laparoscopic appendectomy: validation, reliability, and clinical correlation

Danit Dayan iD, Nadav Dvir, Haneen Agbariya, Eran Nizri

Surgical Endoscopy · 2024

DOI: 10.1007/s00464-024-10847-2 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Surgical Endoscopy, 2024. Verfasst von Danit Dayan und 3 weiteren Autor:innen. Beteiligte Einrichtung: Division of General Surgery, Affiliated to Sackler Faculty of Medicine, Tel Aviv Medical Center, Tel Aviv University, 6, Weizman St., 6423906, Tel Av…. Hauptthemen laut MEDLINE: Appendectomy, Laparoscopy, Artificial Intelligence. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 31 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Application of artificial intelligence (AI) in general surgery is evolving. Real-world implementation of an AI-based computer-vision model in laparoscopic appendectomy (LA) is presented. We aimed to evaluate (1) its accuracy in complexity grading and safety adherence, (2) clinical correlation to outcomes. METHODS: A retrospective single-center study of 499 consecutive LA videos, captured and analyzed by 'Surgical Intelligence Platform,' Theator Inc. (9/2020-5/2022). Two expert surgeons viewed all videos and manually graded complexity and safety adherence. Automated annotations were compared to surgeons' assessments. Inter-surgeons' agreements were measured. Since 7/2021 videos were linked to patients' admission numbers. Data retrieval from medical records was performed (n = 365). Outcomes were compared between high and low complexity grades. RESULTS: Low and high complexity grades comprised 74.8 and 25.2% of 499 videos. Surgeons' agreements were high (76.9-94.4%, kappa 0.77/0.91; p < 0.001) for all annotated complexity grades. Surgeons' agreements were also high (96.0-99.8%, kappa 0.78/0.87; p < 0.001) for full safety adherence, whereas agreement was moderate in partial safety adherence and none (32.8-58.8%). Inter-surgeons' agreements were high for complexity grading (kappa 0.86, p < 0.001) and safety adherence (kappa 0.88, p < 0.001). Comparing high to low grade complexity, preoperative clinical features were similar, except larger appendix diameter on imaging (13.4 ± 4.4 vs. 10.5 ± 3.0 mm, p < 0.001). Intraoperative outcomes were significantly higher (p < 0.001), including time to achieve critical view of safety (29.6, IQR 19.1-41.6 vs. 13.7, IQR 8.5-21.1 min), operative duration (45.3, IQR 37.7-65.2 vs. 25.0, IQR 18.3-32.7 min), and intraoperative events (39.4% vs. 5.9%). Postoperative outcomes (7.4% vs. 9.2%) including surgical complications, mortality, and readmissions were comparable (p = 0.6), except length of stay (4, IQR 2-5.5 vs. 1, IQR 1-2 days; p < 0.001). CONCLUSION: The model accurately assesses complexity grading and full safety achievement. It can serve to predict operative time and intraoperative course, whereas no clinical correlation was found regarding postoperative outcomes. Further studies are needed.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AppendectomyLaparoscopyArtificial IntelligenceHumansRetrospective StudiesFemaleMaleAdultReproducibility of ResultsMiddle AgedAppendicitisVideo RecordingClinical Competence

Stichwörter der Autor:innen

AppendectomyArtificial intelligenceComplexityComputer visionLaparoscopySafety

Autor:innen und Institutionen

  • Division of General Surgery, Affiliated to Sackler Faculty of Medicine, Tel Aviv Medical Center, Tel Aviv University, 6, Weizman St., 6423906, Tel Aviv-Yafo, Israel. danitd.75@gmail.com.
  • Division of General Surgery, Affiliated to Sackler Faculty of Medicine, Tel Aviv Medical Center, Tel Aviv University, 6, Weizman St., 6423906, Tel Aviv-Yafo, Israel.

ORCID-Profile: Danit Dayan

Zitieren

APA

Dayan, D., Dvir, N., Agbariya, H., & Nizri, E. (2024). Implementation of artificial intelligence-based computer vision model in laparoscopic appendectomy: validation, reliability, and clinical correlation. Surgical Endoscopy. https://doi.org/10.1007/s00464-024-10847-2

Vancouver

Dayan D, Dvir N, Agbariya H, Nizri E. Implementation of artificial intelligence-based computer vision model in laparoscopic appendectomy: validation, reliability, and clinical correlation. Surgical Endoscopy. 2024. doi:10.1007/s00464-024-10847-2

BibTeX
@article{Dayan2024,
  author = {Dayan, Danit and Dvir, Nadav and Agbariya, Haneen and Nizri, Eran},
  title = {Implementation of artificial intelligence-based computer vision model in laparoscopic appendectomy: validation, reliability, and clinical correlation},
  journal = {Surgical Endoscopy},
  year = {2024},
  doi = {10.1007/s00464-024-10847-2}
}
Kostenlos starten →