New gel immersion endoscopic ultrasonography technique for accurate periampullary evaluation
Surgical Endoscopy · 2024
DOI: 10.1007/s00464-024-10762-6 ↗Kurz gefasst
Fachartikel in der Zeitschrift Surgical Endoscopy, 2024. Verfasst von Hiroki Sato und 10 weiteren Autor:innen. Beteiligte Einrichtung: Division of Gastroenterology, Department of Internal Medicine, Asahikawa Medical University, 2-1 Midorigaoka-Higashi, Asahikawa, Hokkaido, 078-8510, …. Hauptthemen laut MEDLINE: Ampulla of Vater, Common Bile Duct Neoplasms. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 14 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Visualization of the pancreatobiliary junction is one of the challenges faced by endoscopic ultrasonography (EUS). The water-filling technique, which allows for the observation of the ampulla at a suitable distance by injecting water into the lumen of the duodenum, was used for this purpose. However, a new gel immersion technique has recently been introduced for visualizing the gastrointestinal tract. This study investigated the effectiveness of visualizing the pancreatobiliary junction in EUS by comparing both water filling and the new gel immersion technique in identical cases. METHODS: The study ran from June to December 2021. Ten images from each technique were retrospectively compared by three independent researchers. The primary result of the study was the number of images depicting the "Pancreatic and Biliary Ducts Penetrating the Duodenal Muscularis Propria" (defined as Excellent observation) in each technique. The secondary outcome was defined as gel immersion technique's safety and impact on duodenal lumen distension. RESULTS: Ten patients used the gel immersion technique. All patients underwent the water-filling technique first, followed by gel injection after the water was completely aspirated. The average number of pictures rated as "Excellent observation," which is the primary outcome, was significantly higher with the gel immersion technique than with water filling, and no adverse events were observed. The subanalysis revealed that both convex and radial echoendoscopes are equally effective at depicting the ampulla with the gel immersion technique. CONCLUSIONS: The ability to depict the pancreatobiliary junction using the gel immersion technique is superior to that of the water-filling method, which may allow for a more detailed assessment of the ampullary region with both radial and convex echoendoscopes. This can be a useful EUS technique for diagnosing pancreaticobiliary maljunction or periampullary tumors.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Division of Gastroenterology, Department of Internal Medicine, Asahikawa Medical University, 2-1 Midorigaoka-Higashi, Asahikawa, Hokkaido, 078-8510, Japan.
- Division of Gastroenterology, Department of Internal Medicine, Asahikawa Medical University, 2-1 Midorigaoka-Higashi, Asahikawa, Hokkaido, 078-8510, Japan. fjym@asahikawa-med.ac.jp.
ORCID-Profile: Hiroki Sato
Zitieren
APA
Sato, H., Kawabata, H., Iwamoto, H., Okada, T., Fujibayashi, S., Takahashi, K., Kitano, Y., Goto, T., Mizukami, Y., Okumura, T., & Fujiya, M. (2024). New gel immersion endoscopic ultrasonography technique for accurate periampullary evaluation. Surgical Endoscopy. https://doi.org/10.1007/s00464-024-10762-6
Vancouver
Sato H, Kawabata H, Iwamoto H, Okada T, Fujibayashi S, Takahashi K, et al. New gel immersion endoscopic ultrasonography technique for accurate periampullary evaluation. Surgical Endoscopy. 2024. doi:10.1007/s00464-024-10762-6
BibTeX
@article{Sato2024,
author = {Sato, Hiroki and Kawabata, Hidemasa and Iwamoto, Hidetaka and Okada, Tetsuhiro and Fujibayashi, Shugo and Takahashi, Kenji and Kitano, Yohei and Goto, Takuma and Mizukami, Yusuke and Okumura, Toshikatsu and Fujiya, Mikihiro},
title = {New gel immersion endoscopic ultrasonography technique for accurate periampullary evaluation},
journal = {Surgical Endoscopy},
year = {2024},
doi = {10.1007/s00464-024-10762-6}
}
EUVIMED