EUVIMEDEUVIMED entdecken
Querschnittstudie

Reliability of Measuring Geniohyoid Cross-Sectional Area with B-Mode Ultrasound

Barbara R Pauloski iD, Kacey M Yahnke

Dysphagia · 2025

DOI: 10.1007/s00455-024-10712-3 ↗

Kurz gefasst

Querschnittstudie in der Zeitschrift Dysphagia, 2025. Verfasst von Barbara R Pauloski und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Communication Sciences and Disorders, College of Health Sciences, University of Wisconsin Milwaukee, 2400 E. Hartford Avenue, Suite 840…. Hauptthemen laut MEDLINE: Neck Muscles, Deglutition. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 66 Literaturangaben. Gefördert von: University of Wisconsin Milwaukee.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

B-mode ultrasound is a safe noninvasive procedure that has been used to characterize aspects of the oropharyngeal swallow. The submental suprahyoid muscles are often investigated with ultrasound because of their contributions to hyolaryngeal elevation. There are several techniques for positioning the ultrasound transducer in the coronal plane, however, there is limited research on how reliability of measurement of the cross-sectional area (CSA) of the geniohyoid differs across transducer placement technique. This study examined three methods of transducer placement in the coronal plane by two examiners to determine the reliability of measurement of CSA of the geniohyoid muscle. Forty healthy adults participated in the study. Each participant's geniohyoid muscles were imaged using B-mode ultrasound under three transducer placement conditions in the coronal plane by two examiners. Geniohyoid CSA was measured from each ultrasound image. A three-way mixed-methods ANOVA was used to determine whether there were significant differences in geniohyoid CSA among transducer position conditions, trials, and examiners. There were significant differences among the transducer placement conditions, indicating that each condition was measuring a different portion of the muscle. There were no significant differences among repeated trials nor between examiners within each method of transducer placement. All three conditions of transducer placement were reliable at measuring geniohyoid CSA across trials and examiners. This study emphasizes the need for consistency of placement, whichever method is selected. It also highlights the need for researchers to provide a precise description of methods for positioning the transducer so that placement is reproducible.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Neck MusclesDeglutitionHumansUltrasonographyReproducibility of ResultsFemaleMaleAdultYoung AdultMiddle AgedTransducersHealthy Volunteers

Stichwörter der Autor:innen

DeglutitionDeglutition disordersGeniohyoidHealthy adultsReliabilityUltrasound

Autor:innen und Institutionen

  • Department of Communication Sciences and Disorders, College of Health Sciences, University of Wisconsin Milwaukee, 2400 E. Hartford Avenue, Suite 840, Milwaukee, WI, 53211, USA. pauloski@uwm.edu.
  • Department of Communication Sciences and Disorders, College of Health Sciences, University of Wisconsin Milwaukee, 2400 E. Hartford Avenue, Suite 840, Milwaukee, WI, 53211, USA.
  • Manhattan Star Academy, 180 Amsterdam Avenue, New York, NY, 10023, USA.

ORCID-Profile: Barbara R Pauloski

Förderung

  • University of Wisconsin Milwaukee

Zitieren

APA

Pauloski, B. R., & Yahnke, K. M. (2025). Reliability of Measuring Geniohyoid Cross-Sectional Area with B-Mode Ultrasound. Dysphagia. https://doi.org/10.1007/s00455-024-10712-3

Vancouver

Pauloski BR, Yahnke KM. Reliability of Measuring Geniohyoid Cross-Sectional Area with B-Mode Ultrasound. Dysphagia. 2025. doi:10.1007/s00455-024-10712-3

BibTeX
@article{Pauloski2025,
  author = {Pauloski, Barbara R and Yahnke, Kacey M},
  title = {Reliability of Measuring Geniohyoid Cross-Sectional Area with B-Mode Ultrasound},
  journal = {Dysphagia},
  year = {2025},
  doi = {10.1007/s00455-024-10712-3}
}
Kostenlos starten →