Application of dielectric spectroscopy combined with simple linear and multivariate modelling for in-line monitoring of biomass concentration in E. coli cultures
Bioprocess and Biosystems Engineering · 2026
DOI: 10.1007/s00449-026-03405-8 ↗Kurz gefasst
Fachartikel in der Zeitschrift Bioprocess and Biosystems Engineering, 2026. Verfasst von César Rodriguez-Fano und 3 weiteren Autor:innen. Beteiligte Einrichtung: BioDyMIAResearch Unit, Université Lyon 1, ISARA Lyon, 23 rue Jean Baldassini, 69007, Lyon, France. cesar-enrique.rodriguez-fano@univ-lyon1.fr. Hauptthemen laut MEDLINE: Escherichia coli, Biomass, Dielectric Spectroscopy, Bioreactors. Die Arbeit nennt 28 Literaturangaben. Gefördert von: Région Auvergne-Rhône-Alpes.
Abstract (Originalsprache)
Biomass concentration is a crucial parameter while monitoring Escherichia coli bioprocesses. Real-time monitoring of this attribute is preferable to discrete measurement, as it immediately detects deviations, reduces sampling efforts and thereby minimizes the risk of contamination. Therefore, the potential of dielectric spectroscopy for continuous monitoring of E. coli cultures was investigated. Two datasets were acquired across culture batches in a benchtop bioreactor: ∆ permittivity and the dielectric spectrum. For each batch, variations in ∆ permittivity followed the OD600nm trend, highlighting the E. coli growth phases. The dielectric spectra also evolved throughout the batches, and Principal Component Analysis (PCA) revealed at least two main contributors to spectral variability. Both datasets were then used to estimate the OD600nm using either simple linear or multivariate Partial Least Squares (PLS) modelling, with the aim of comparing these two strategies. For four calibration batches, both simple linear and PLS models generally predicted the OD600nm accurately, with only minor differences. For a validation batch, both strategies showed good predictions during exponential growth but were slightly less accurate in the other bacterial culture phases. Prediction noise was also evaluated, and PLS provided slightly less noisy predictions than the simple linear model. Overall, this indicates that simple linear and PLS predictions are not considerably different, and both modelling strategies can be used indistinguishably to calibrate the dielectric signals for estimating the OD600nm in E. coli cultures.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- BioDyMIAResearch Unit, Université Lyon 1, ISARA Lyon, 23 rue Jean Baldassini, 69007, Lyon, France. cesar-enrique.rodriguez-fano@univ-lyon1.fr.
- Axel'One Innovative Processes, Les Levées, 69360, Solaize, France.
- BioDyMIA Research Unit, Université Lyon 1, ISARA Lyon, Technopole Alimentec, 155 rue Henri de Boissieu, 01000, Bourg-en-Bresse, France.
- BioDyMIA Research Unit, ISARA Lyon, Université Lyon 1, 23 rue Jean Baldassini, 69007, Lyon, France.
Förderung
- Région Auvergne-Rhône-Alpes
Zitieren
APA
Rodriguez-Fano, C., Caillol, N., Degraeve, P., & Demarigny, Y. (2026). Application of dielectric spectroscopy combined with simple linear and multivariate modelling for in-line monitoring of biomass concentration in E. coli cultures. Bioprocess and Biosystems Engineering. https://doi.org/10.1007/s00449-026-03405-8
Vancouver
Rodriguez-Fano C, Caillol N, Degraeve P, Demarigny Y. Application of dielectric spectroscopy combined with simple linear and multivariate modelling for in-line monitoring of biomass concentration in E. coli cultures. Bioprocess and Biosystems Engineering. 2026. doi:10.1007/s00449-026-03405-8
BibTeX
@article{RodriguezFano2026,
author = {Rodriguez-Fano, César and Caillol, Noémie and Degraeve, Pascal and Demarigny, Yann},
title = {Application of dielectric spectroscopy combined with simple linear and multivariate modelling for in-line monitoring of biomass concentration in E. coli cultures},
journal = {Bioprocess and Biosystems Engineering},
year = {2026},
doi = {10.1007/s00449-026-03405-8}
}
EUVIMED