EUVIMEDEUVIMED entdecken
Beobachtungsstudie

Use of the NIPE monitor to continuously assess the nociception–comfort balance in mechanically ventilated, sedated, preterm infants: An observational study

Anne Wojtanowski, Kevin Le Duc, Emeline Cailliau, Julien De Jonckheere, Laurent Storme, Mathilde Flocteil, Mohamed Riadh Boukhris

European Journal of Pediatrics · 2026

DOI: 10.1007/s00431-026-07492-3 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift European Journal of Pediatrics, 2026. Verfasst von Anne Wojtanowski und 6 weiteren Autor:innen. Beteiligte Einrichtung: CIC IT 1403, CHU Lille, 59000, Lille, France. anne.wojtanowski@chu-lille.fr. Hauptthemen laut MEDLINE: Respiration, Artificial, Pain Measurement, Nociception. Die Arbeit nennt 17 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

To establish whether the Newborn Infant Parasympathetic Evaluation (NIPE) score provides information on the nociception–comfort balance during the routine care of mechanically ventilated, sedated, premature infants. A single-center, prospective, observational study in a tertiary neonatal intensive care unit. Premature infants born before 33 weeks of gestational age and who were mechanically ventilated and received continuous sedation or analgesics within the first 7 days post-partum. Continuous NIPE monitoring and repeated assessments of the Premature Infant Pain Profile–Revised (PIPP-R) score during routine care involving multiple potentially painful procedures. The NIPE score was recorded continuously from 10 min before the care procedure until 10 min after the end of the care procedure. The PIPP-R score was rated before, during, and after care by trained nurses blinded to the NIPE score. Fifty infants were included. The PIPP-R score increased significantly during care and decreased afterwards; conversely, the NIPE score decreased during care and increased afterwards (both p < 0.0001). Higher PIPP-R scores were significantly associated with lower NIPE scores in a linear mixed-effects model accounting for repeated measurements ( p < 0.001). Discriminant performance varied according to the PIPP-R threshold considered, with an AUROC of 0.67 [95% confidence interval: 0.58–0.76] for the lower PIPP-R threshold and 0.79 [95% confidence interval: 0.70–0.88] for the higher threshold. Conclusion : In mechanically ventilated, sedated, premature infants, the NIPE score provides continuous autonomic information during routine care and may complement multidimensional clinical pain assessments in critically ill newborns. What is Known: • Mechanically ventilated, sedated preterm infants frequently undergo painful procedures in NICU, while their behavioral responses may be attenuated by sedation, making pain assessment challenging . • The NIPE monitor continuously provides assessment of autonomic activity, reflecting the balance between nociception and pain . What is New: • In mechanically ventilated, sedated preterm infants, NIPE scores decreased during routine care and increased afterward . • NIPE showed dynamic changes during prolonged care episodes and provided continuous autonomic information that complemented behavioral scales .

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Respiration, ArtificialPain MeasurementNociceptionHumansInfant, NewbornInfant, PrematureProspective StudiesFemaleMaleIntensive Care Units, NeonatalMonitoring, Physiologic

Stichwörter der Autor:innen

Autonomic nervous systemComfortIntensive carePremature

Autor:innen und Institutionen

  • CIC IT 1403, CHU Lille, 59000, Lille, France. anne.wojtanowski@chu-lille.fr.
  • ULR 2694 METRICS: Evaluation Des Technologies de Santé Et Des Pratiques Médicales - Perinatal Environment and Health, Univ. Lille, 59000, Lille, France. anne.wojtanowski@chu-lille.fr.
  • ULR 2694 METRICS: Evaluation Des Technologies de Santé Et Des Pratiques Médicales - Perinatal Environment and Health, Univ. Lille, 59000, Lille, France.
  • Department of Neonatology, CHU Lille, Jeanne de Flandre Hospital, 59000, Lille, France.
  • Biostatistics Department, CHU Lille, 59000, Lille, France.
  • CIC IT 1403, CHU Lille, 59000, Lille, France.

Zitieren

APA

Wojtanowski, A., Le Duc, K., Cailliau, E., De Jonckheere, J., Storme, L., Flocteil, M., & Boukhris, M. R. (2026). Use of the NIPE monitor to continuously assess the nociception–comfort balance in mechanically ventilated, sedated, preterm infants: An observational study. European Journal of Pediatrics. https://doi.org/10.1007/s00431-026-07492-3

Vancouver

Wojtanowski A, Le Duc K, Cailliau E, De Jonckheere J, Storme L, Flocteil M, et al. Use of the NIPE monitor to continuously assess the nociception–comfort balance in mechanically ventilated, sedated, preterm infants: An observational study. European Journal of Pediatrics. 2026. doi:10.1007/s00431-026-07492-3

BibTeX
@article{Wojtanowski2026,
  author = {Wojtanowski, Anne and Le Duc, Kevin and Cailliau, Emeline and De Jonckheere, Julien and Storme, Laurent and Flocteil, Mathilde and Boukhris, Mohamed Riadh},
  title = {Use of the NIPE monitor to continuously assess the nociception–comfort balance in mechanically ventilated, sedated, preterm infants: An observational study},
  journal = {European Journal of Pediatrics},
  year = {2026},
  doi = {10.1007/s00431-026-07492-3}
}
Kostenlos starten →