Feasibility and procedural outcomes of ultrasound-guided brachiocephalic vein cannulation in neonates weighing less than 1,000 g: a prospective study
European Journal of Pediatrics · 2026
DOI: 10.1007/s00431-026-07425-0 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift European Journal of Pediatrics, 2026. Verfasst von Fiorentino Grasso und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Translational Medical Sciences, Neonatology and Neonatal Intensive Care Unit, University of Naples Federico II, Naples, Italy. fiorenti…. Hauptthemen laut MEDLINE: Brachiocephalic Veins, Ultrasonography, Interventional, Catheterization, Central Venous. Die Arbeit nennt 20 Literaturangaben.
Abstract (Originalsprache)
Purpose
To evaluate the anatomical feasibility and procedural outcomes of ultrasound-guided right brachiocephalic vein cannulation for placing non-tunnelled centrally inserted central catheters in neonates weighing less than 1,000 g.
Methods
This single-center, prospective observational study assessed right BCV diameter using high-frequency ultrasound (Phase 1), defining anatomical feasibility as a diameter ≥ 2.0 mm (suitable for a 2 French catheter). Subsequently, ultrasound-guided cannulation was evaluated using a standardized "micro-access" bundle (Phase 2), measuring technical success, first-pass rate, and immediate complications.
Results
Sixty neonates were enrolled (median weight, 865 g [interquartile interval, 620 to 970 g]). Anatomical feasibility was 100% (60/60); median diameter was 2.8 mm (interquartile interval, 2.6 to 3.0 mm). Right brachiocephalic vein diameter was significantly smaller in neonates weighing less than 750 g ( n = 22) than in those weighing 750 to 1,000 g ( n = 38) (median, 2.6 mm [interquartile interval, 2.4 to 2.7 mm] versus 2.95 mm [interquartile interval, 2.8 to 3.1 mm]; p < 0.001). Fifty-two catheterization procedures were performed in 47 infants. Technical success was 100% (52/52), with a first-pass success rate of 76.9% (40/52). No statistically significant difference in first-pass success was detected between the two weight groups (77.3% [17/22] in < 750 g versus 76.7% [23/30] in ≥ 750 g; p = 1.00). No immediate complications were observed (0/52).
Conclusion
Ultrasound-guided right brachiocephalic vein cannulation is anatomically feasible and safe in neonates weighing less than 1,000 g, providing a reproducible central venous access pathway when performed with a standardized micro-access protocol. What is Known: • Centrally inserted central catheters offer superior performance compared to peripherally inserted central catheters in infants, although clinical data regarding their placement in micro-preterm neonates remain limited. What is New: • The right brachiocephalic vein caliber consistently exceeds 2.0 mm in neonates weighing < 1,000 g, and a standardized "micro-access" bundle yields high technical success without immediate mechanical complications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Translational Medical Sciences, Neonatology and Neonatal Intensive Care Unit, University of Naples Federico II, Naples, Italy. fiorentino.grasso89@gmail.com.
- Department of Translational Medical Sciences, Neonatology and Neonatal Intensive Care Unit, University of Naples Federico II, Naples, Italy.
ORCID-Profile: Fiorentino Grasso
Zitieren
APA
Grasso, F., Capasso, A., Capasso, L., & Raimondi, F. (2026). Feasibility and procedural outcomes of ultrasound-guided brachiocephalic vein cannulation in neonates weighing less than 1,000 g: a prospective study. European Journal of Pediatrics. https://doi.org/10.1007/s00431-026-07425-0
Vancouver
Grasso F, Capasso A, Capasso L, Raimondi F. Feasibility and procedural outcomes of ultrasound-guided brachiocephalic vein cannulation in neonates weighing less than 1,000 g: a prospective study. European Journal of Pediatrics. 2026. doi:10.1007/s00431-026-07425-0
BibTeX
@article{Grasso2026,
author = {Grasso, Fiorentino and Capasso, Antonella and Capasso, Letizia and Raimondi, Francesco},
title = {Feasibility and procedural outcomes of ultrasound-guided brachiocephalic vein cannulation in neonates weighing less than 1,000 g: a prospective study},
journal = {European Journal of Pediatrics},
year = {2026},
doi = {10.1007/s00431-026-07425-0}
}
EUVIMED