EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Bubbles in the barely born—contrast-enhanced ultrasound in neonates: a single-center experience

Alexandros Rahn, Thomas Müller, Diane Renz, Jens Drube, Doris Franke

European Journal of Pediatrics · 30.06.2026 · 185 (7)

DOI: 10.1007/s00431-026-07166-0 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Journal of Pediatrics, online erschienen am 30.06.2026. Verfasst von Alexandros Rahn und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pediatric Pulmonology, Allergology and Neonatology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hannover, Germany. rahn.alexan…. Hauptthemen laut MEDLINE: Contrast Media. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Medizinische Hochschule Hannover (MHH).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

To assess clinical value, safety, and applicability of contrast-enhanced ultrasound (CEUS) in neonates, focusing on bedside use in intensive care. This retrospective single-center study included 23 neonates undergoing intravenous CEUS between 2010 and 2024, including seven preterm infants. The liver ( n = 18) was the most frequently examined organ, followed by kidneys ( n = 2), brain ( n = 2), and adrenals ( n = 1). Findings were compared with MRI ( n = 10), CT ( n = 3), or biopsy ( n = 8), when available. In nine cases, CEUS findings were consistent with clinical course and treatment response only, without an independent reference standard. Among the 14 cases with available reference diagnostics, CEUS established the diagnosis first in ten (71.4%); histological confirmation was available in eight cases, with concordance in five (62.5%). 13 examinations (56.5%) were performed for bedside problem-solving in the neonatal intensive care unit, and no adverse events were observed. Conclusion : CEUS provided clinically relevant diagnostic information in neonates, including preterm and critically ill infants and was well tolerated. CEUS was particularly valuable in hepatic vascular tumors, where it could provide a definite diagnosis, enabled hemodynamic assessment, supported treatment decisions, and aided identification of potentially life-threatening complications. Bedside use enabled timely diagnosis without sedation, intubation, or patient transport, thereby supporting minimal handling. In selected cases, CEUS may reduce the need for cross-sectional imaging. Despite off-label use, our findings suggest a beneficial role for CEUS in neonatal imaging, predominantly for hepatic indications. What is Known: • Contrast-enhanced ultrasound (CEUS) is a radiation-free, bedside-compatible imaging technique with an established safety profile in pediatric patients. • Neonatal CEUS experience is limited to small case series, predominantly reporting cerebral applications. What is New: • CEUS was feasible and well tolerated in neonates including preterm infants, with no adverse events in 23 examinations. • CEUS yielded clinically relevant diagnostic information across a range of indications, primarily hepatic, encompassing both focal lesions and perfusion assessment, supporting clinical decision-making in neonatal care.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Contrast MediaHumansInfant, NewbornRetrospective StudiesUltrasonographyMaleFemaleInfant, PrematureMagnetic Resonance ImagingIntensive Care Units, Neonatal

Stichwörter der Autor:innen

Contrast-enhanced ultrasoundCritical careNICUNeonatesPOCUSPoint-of-care ultrasoundPreterm infants

Substanzen

Contrast Media

Autor:innen und Institutionen

  • Department of Pediatric Pulmonology, Allergology and Neonatology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hannover, Germany. rahn.alexandros@mh-hannover.de.
  • Department of Pediatric Pulmonology, Allergology and Neonatology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hannover, Germany.
  • Department of Pediatric Radiology, Institute of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hannover, Germany.
  • Department of Pediatric Kidney, Liver and Metabolic Diseases, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hannover, Germany.

Förderung

  • Medizinische Hochschule Hannover (MHH)

Zitieren

APA

Rahn, A., Müller, T., Renz, D., Drube, J., & Franke, D. (2026). Bubbles in the barely born—contrast-enhanced ultrasound in neonates: a single-center experience. European Journal of Pediatrics, 185(7). https://doi.org/10.1007/s00431-026-07166-0

Vancouver

Rahn A, Müller T, Renz D, Drube J, Franke D. Bubbles in the barely born—contrast-enhanced ultrasound in neonates: a single-center experience. European Journal of Pediatrics. 2026;185(7). doi:10.1007/s00431-026-07166-0

BibTeX
@article{Rahn2026,
  author = {Rahn, Alexandros and Müller, Thomas and Renz, Diane and Drube, Jens and Franke, Doris},
  title = {Bubbles in the barely born—contrast-enhanced ultrasound in neonates: a single-center experience},
  journal = {European Journal of Pediatrics},
  year = {2026},
  volume = {185},
  number = {7},
  doi = {10.1007/s00431-026-07166-0}
}
Kostenlos starten →