EUVIMEDEUVIMED entdecken
Crossref

Impact of routine bedside lung ultrasound implementation on chest x-ray requests for mechanically ventilated children: a before-after uncontrolled quality improvement project

Farah Thabet, Seyfeddine Zayani, Abir Daya, Cyrine Ben Nasrallah, Chokri Chouchane, Slaheddine Chouchane

European Journal of Pediatrics · 2024

DOI: 10.1007/s00431-024-05710-4 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Journal of Pediatrics, 2024. Verfasst von Farah Thabet und 5 weiteren Autor:innen. Beteiligte Einrichtung: Pediatric Department, Fattouma Bourguiba University Hospital, Monastir, Tunisia. thabetfarah@yahoo.fr. Hauptthemen laut MEDLINE: Quality Improvement, Ultrasonography, Respiration, Artificial, Intensive Care Units, Pediatric. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 29 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Lung imaging techniques are crucial for managing ventilated patients in pediatric intensive care units (PICUs). Bedside chest x-ray has limitations such as low sensitivity and radiation exposure risks. Recently, lung ultrasound has emerged as a promising technology offering advantages such as real-time monitoring and radiation-free imaging. However, the integration of lung ultrasound into clinical practice raises questions about its impact on chest x-ray prescriptions. This study aims to assess whether implementing lung ultrasound reduces reliance on chest x-rays for ventilated pediatric patients in the PICU. This before-and-after uncontrolled quality improvement project was conducted from January 2022 to December 2023 in a referral PICU. The study included three phases: retrospective evaluation, learning phase, and prospective evaluation. Patients aged under 14 years, intubated, and ventilated for ≤ 30 days were included. Lung ultrasound was performed using a standardized protocol, and chest x-rays were conducted as per clinical indications. During the study period, 430 patients were admitted to the PICU, with 142 requiring mechanical ventilation. Implementation of routine bedside lung ultrasound led to a 39% reduction in chest x-ray requests (p < 0.001). Additionally, there was a significant decrease in irradiation exposure and a 27% reduction in costs associated with chest x-rays.Conclusion: Routine bedside lung ultrasound is a valuable tool in the modern PICU, it reduces the number of chest x-rays, with reduced radiation exposure and a potential cost savings. What is known: • Bedside chest x-ray is the main imaging study in ventilated pediatric patients • Chest x-ray is a valuable tool in pediatric critical care but it is associated with irradiation exposure What is new: • Implementation of bedside lung ultrasound in pediatric critical care unites reduces the chest x-rays requests and therefore patient-irradiation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Quality ImprovementUltrasonographyRespiration, ArtificialIntensive Care Units, PediatricLungRadiography, ThoracicHumansChildMaleFemaleChild, PreschoolInfantRetrospective StudiesProspective StudiesAdolescentPoint-of-Care SystemsPoint-of-Care Testing

Stichwörter der Autor:innen

Chest x-rayIrradiationLung ultrasoundPediatric intensive care

Autor:innen und Institutionen

  • Pediatric Department, Fattouma Bourguiba University Hospital, Monastir, Tunisia. thabetfarah@yahoo.fr.
  • Pediatric Department, Fattouma Bourguiba University Hospital, Monastir, Tunisia.
  • Department of Preventive and Epidemiology Medicine, Fattouma Bourguiba University Hospital, Monastir, Tunisia.

Zitieren

APA

Thabet, F., Zayani, S., Daya, A., Ben Nasrallah, C., Chouchane, C., & Chouchane, S. (2024). Impact of routine bedside lung ultrasound implementation on chest x-ray requests for mechanically ventilated children: a before-after uncontrolled quality improvement project. European Journal of Pediatrics. https://doi.org/10.1007/s00431-024-05710-4

Vancouver

Thabet F, Zayani S, Daya A, Ben Nasrallah C, Chouchane C, Chouchane S. Impact of routine bedside lung ultrasound implementation on chest x-ray requests for mechanically ventilated children: a before-after uncontrolled quality improvement project. European Journal of Pediatrics. 2024. doi:10.1007/s00431-024-05710-4

BibTeX
@article{Thabet2024,
  author = {Thabet, Farah and Zayani, Seyfeddine and Daya, Abir and Ben Nasrallah, Cyrine and Chouchane, Chokri and Chouchane, Slaheddine},
  title = {Impact of routine bedside lung ultrasound implementation on chest x-ray requests for mechanically ventilated children: a before-after uncontrolled quality improvement project},
  journal = {European Journal of Pediatrics},
  year = {2024},
  doi = {10.1007/s00431-024-05710-4}
}
Kostenlos starten →