Thoracic fluid content (TFC) using electrical cardiometry versus lung ultrasound in the diagnosis of transient tachypnea of newborn
European Journal of Pediatrics · 2024
DOI: 10.1007/s00431-024-05507-5 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift European Journal of Pediatrics, 2024. Verfasst von Nagwa Mohamed Abd El-Fattah und 3 weiteren Autor:innen. Beteiligte Einrichtung: Pediatric Department, Faculty of Medicine, Tanta University, El Bahr St., Tanta Qism 2, Tanta, Gharbia Governorate, 31527, Egypt. Hauptthemen laut MEDLINE: Transient Tachypnea of the Newborn, Ultrasonography, Lung. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Tanta University.
Abstract (Originalsprache)
This study aimed to evaluate TFC by EC versus lung ultrasound (LUS) findings for diagnosing and follow-up of TTN in late preterm and term neonates. This prospective observational study was conducted on 80 neonates with gestational age ≥ 34 weeks. TTN group included 40 neonates diagnosed with TTN, and no lung disease (NLD) group included 40 neonates without respiratory distress. LUS and EC were performed within the first 24 h of life and repeated after 72 h. There was a statistically significant increase in TFC in TTN group on D1 [48.48 ± 4.86 (1 KOhm −1 )] compared to NLD group [32.95 ± 4.59 (1 KOhm −1 )], and then significant decrease in TFC in D3 [34.90 ± 4.42 (1 KOhm −1 )] compared to D1 in the TTN group. There was a significant positive correlation between both TFC and LUS with Downes’ score, TTN score, and duration of oxygen therapy in the TTN group. Conclusion : Both LUS and TFC by EC provide good bedside tools that could help to diagnose and monitor TTN. TFC showed a good correlation with LUS score and degree of respiratory distress. What is Known: • Transient tachypnea of the newborn (TTN) is the most common cause of respiratory distress in newborns. • TTN is a diagnosis of exclusion, there are no specific clinical parameters or biomarker has been identified for TTN. What is New: • Thoracic fluid content (TFC) by electrical cardiometry is a new parameter to evaluate lung fluid volume and could help to diagnose and monitor TTN and correlates with lung ultrasound score.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Pediatric Department, Faculty of Medicine, Tanta University, El Bahr St., Tanta Qism 2, Tanta, Gharbia Governorate, 31527, Egypt.
- Pediatric Department, Faculty of Medicine, Tanta University, El Bahr St., Tanta Qism 2, Tanta, Gharbia Governorate, 31527, Egypt. hmahdy71@yahoo.com.
- Radiology Department, Faculty of Medicine, Tanta University, Tanta, Egypt.
Förderung
- Tanta University
Zitieren
APA
El-Fattah, N. M. A., El-Mahdy, H. S., Hamisa, M. F., & Ibrahim, A. M. (2024). Thoracic fluid content (TFC) using electrical cardiometry versus lung ultrasound in the diagnosis of transient tachypnea of newborn. European Journal of Pediatrics. https://doi.org/10.1007/s00431-024-05507-5
Vancouver
El-Fattah NMA, El-Mahdy HS, Hamisa MF, Ibrahim AM. Thoracic fluid content (TFC) using electrical cardiometry versus lung ultrasound in the diagnosis of transient tachypnea of newborn. European Journal of Pediatrics. 2024. doi:10.1007/s00431-024-05507-5
BibTeX
@article{ElFattah2024,
author = {El-Fattah, Nagwa Mohamed Abd and El-Mahdy, Heba Saied and Hamisa, Manal Fathy and Ibrahim, Ashraf Mohamed},
title = {Thoracic fluid content (TFC) using electrical cardiometry versus lung ultrasound in the diagnosis of transient tachypnea of newborn},
journal = {European Journal of Pediatrics},
year = {2024},
doi = {10.1007/s00431-024-05507-5}
}
EUVIMED