Repeatability of PDA diameter measurements on echocardiography
European Journal of Pediatrics · 2022-01 · 181 (1) · 403-406
DOI: 10.1007/s00431-021-04178-w ↗Kurz gefasst
Fachartikel in der Zeitschrift European Journal of Pediatrics, online erschienen am 29.06.2021. Verfasst von Kunal Babla und 4 weiteren Autor:innen. Beteiligte Einrichtung: Neonatal Intensive Care Unit, St George's University Hospital NHS Trust, Blackshaw Road, London, SW17 0QT, UK. Hauptthemen laut MEDLINE: Bronchopulmonary Dysplasia, Ductus Arteriosus, Patent. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 8 Literaturangaben.
Abstract (Originalsprache)
Diameter of the patent ductus arteriosus (PDA) on transthoracic echocardiography (TTE) is used as a marker of haemodynamic significance. We aimed to assess the intra- and inter-observer variability in PDA diameter in babies born at ≤ 30 weeks' gestation. TTEs for 56 infants were performed by a single neonatologist. Cineloops were stored without measurement annotations. PDAs were measured on 2-dimensional (2D) and Colour Doppler. A second, blinded neonatologist repeated measurements on the same cineloops. The scanning neonatologist repeated measurements at a later date, blinded to original measurements. Inter-observer results showed repeatability coefficients of 1.57 (2D) and 2.18 (Colour), and repeatability index of 73% (2D) and 91% (Colour). Intra-observer results showed repeatability coefficients of 0.99 (2D) and 1.32 (Colour), and repeatability index of 43% (2D) and 49% (Colour).Conclusion: There is significant inter- and intra-observer variability in measurements of PDA diameter, even on the same cineloops. We advise caution when using diameter alone as a marker of haemodynamic significance, and recommend using multiple parameters to determine haemodynamic significance of PDA. What is Known: • PDA is associated with numerous comorbidities such as bronchopulmonary dysplasia, necrotising enterocolitis, intraventricular haemorrhage and mortality. • PDA diameter is commonly measured on transthoracic echocardiography and used as a marker of haemodynamic significance. • A previous, smaller study has shown there may be poor repeatability of PDA diameter measurements in serial echocardiograms. What is New: • There is significant inter-observer variability in 2D and Colour Doppler measurements of PDA internal diameter on TTE in preterm infants. • There is moderate intra-observer correlation of repeated measurements on the same imaging in both 2D and Colour Doppler imaging.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Neonatal Intensive Care Unit, St George's University Hospital NHS Trust, Blackshaw Road, London, SW17 0QT, UK.
- Neonatal Intensive Care Unit, St George's University Hospital NHS Trust, Blackshaw Road, London, SW17 0QT, UK. Anay.Kulkarni@stgeorges.nhs.uk.
Zitieren
APA
Babla, K., Duffy, D., Dumitru, R., Richards, J., & Kulkarni, A. (2022). Repeatability of PDA diameter measurements on echocardiography. European Journal of Pediatrics, 181(1), 403-406. https://doi.org/10.1007/s00431-021-04178-w
Vancouver
Babla K, Duffy D, Dumitru R, Richards J, Kulkarni A. Repeatability of PDA diameter measurements on echocardiography. European Journal of Pediatrics. 2022;181(1):403-406. doi:10.1007/s00431-021-04178-w
BibTeX
@article{Babla2022,
author = {Babla, Kunal and Duffy, Donovan and Dumitru, Ramona and Richards, Justin and Kulkarni, Anay},
title = {Repeatability of PDA diameter measurements on echocardiography},
journal = {European Journal of Pediatrics},
year = {2022},
volume = {181},
number = {1},
pages = {403--406},
doi = {10.1007/s00431-021-04178-w}
}
EUVIMED