Does the stria of Gennari integrity reflect acquired visual field defects?
Brain Structure and Function · 2026
DOI: 10.1007/s00429-026-03191-9 ↗Kurz gefasst
Fachartikel in der Zeitschrift Brain Structure and Function, 2026. Verfasst von Carlien Roelofzen und 6 weiteren Autor:innen. Beteiligte Einrichtung: Spinoza Centre for Neuroimaging, Amsterdam, Netherlands. c.roelofzen@spinozacentre.nl. Hauptthemen laut MEDLINE: Visual Pathways, Visual Fields, Primary Visual Cortex, Hemianopsia. Die Arbeit nennt 26 Literaturangaben. Gefördert von: NWO Vidi, NWO Vici, UitZicht.
Abstract (Originalsprache)
Visual input reaches the primary visual cortex (V1) at the stria of Gennari, a band of highly myelinated fibers at the level of layer IV. Damage to the visual pathways can cause visual field defects (scotomas) that prevent visual input from reaching V1. Here, we evaluate whether the stria of Gennari degrades in the absence of visual input. Using 7 Tesla MRI, we investigate the integrity of the stria of Gennari in case of acquired homonymous visual field defects, in particular hemianopia: the loss of vision in half of the visual field. These visual field defects allow us to compare stria of Gennari integrity between the two hemispheres within the same participant, i.e., the hemisphere that is deprived of visual input (affected hemisphere) versus the hemisphere receiving visual information (unaffected hemisphere). Therefore, we focus on cases of acquired blindness following damage between the optic chiasm and V1. We quantify the stria of Gennari integrity both by measuring the T1-weighted intensity at the middle of cortical depth and using a modeling approach that captures T1-weighted intensity variations across cortical depth. Our results show that the stria of Gennari remains intact in both the affected and unaffected hemisphere, suggesting that the stria of Gennari integrity is not altered in the absence of visual input.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Spinoza Centre for Neuroimaging, Amsterdam, Netherlands. c.roelofzen@spinozacentre.nl.
- Computational Cognitive Neuroscience and Neuroimaging, Royal Netherlands Academy of Arts and Sciences, Netherlands Institute for Neuroscience, Amsterdam, Netherlands. c.roelofzen@spinozacentre.nl.
- Experimental and Applied Psychology, VU University Amsterdam, Amsterdam, Netherlands. c.roelofzen@spinozacentre.nl.
- Ophthalmology, University Medical Center Utrecht, Utrecht, Netherlands.
- Ophthalmology, Amphia Hospital, Breda, Netherlands.
- Bartiméus Diagnostic Centre for Complex Visual Disorders, Zeist, Netherlands.
Förderung
- NWO Vidi
- NWO Vici
- UitZicht
- Biotechnology and Biological Sciences Research Council
- Bial Foundation Grants Programme
Zitieren
APA
Roelofzen, C., Porro, G. L., van Genderen, M. M., Bergsma, D. P., Petridou, N., Dumoulin, S. O., & Fracasso, A. (2026). Does the stria of Gennari integrity reflect acquired visual field defects?. Brain Structure and Function. https://doi.org/10.1007/s00429-026-03191-9
Vancouver
Roelofzen C, Porro GL, van Genderen MM, Bergsma DP, Petridou N, Dumoulin SO, et al. Does the stria of Gennari integrity reflect acquired visual field defects?. Brain Structure and Function. 2026. doi:10.1007/s00429-026-03191-9
BibTeX
@article{Roelofzen2026,
author = {Roelofzen, Carlien and Porro, Giorgio L and van Genderen, Maria M and Bergsma, Douwe P and Petridou, Natalia and Dumoulin, Serge O and Fracasso, Alessio},
title = {Does the stria of Gennari integrity reflect acquired visual field defects?},
journal = {Brain Structure and Function},
year = {2026},
doi = {10.1007/s00429-026-03191-9}
}
EUVIMED