EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Hounsfield unit measurements on computed tomography in elastofibroma dorsi: a patient-level comparison with adjacent skeletal muscle

Atilla Can, Halil Şen, Hüseyin Yıldıran

Langenbeck's Archives of Surgery · 04.11.2026

DOI: 10.1007/s00423-026-04199-9 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Langenbeck's Archives of Surgery, online erschienen am 04.11.2026. Verfasst von Atilla Can und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Elastofibroma dorsi (ED) is a benign soft-tissue tumour typically located in the subscapular region. Hounsfield unit (HU) measurements on computed tomography (CT) may provide quantitative information on lesion attenuation. This study aimed to compare patient-level HU values of ED with those of adjacent skeletal muscle.

Methods

This retrospective, single-centre study included 11 surgically treated patients with histopathologically confirmed ED. Preoperative CT examinations suitable for HU analysis were available for nine patients. For patients with bilateral measurements, right- and left-sided values were averaged to obtain one ED and one adjacent serratus anterior muscle value per patient. Paired differences were assessed for normality and compared using a paired-samples t test.

Results

Ten patients (90.9%) were female and one (9.1%) was male; the mean age was 59.0 ± 11.28 years. Pain and palpable swelling were reported by six (54.5%) and five (45.5%) patients, respectively. In the nine-patient imaging cohort, mean HU values were lower in ED than in adjacent muscle (27.89 ± 12.72 vs. 37.89 ± 10.46 HU). The mean paired difference was 10.0 HU (95% confidence interval, 4.36–15.64 HU; P = 0.003).

Conclusion

ED demonstrated lower patient-level CT attenuation than adjacent skeletal muscle. HU measurement may provide complementary quantitative information when interpreted with characteristic lesion location and morphology; however, diagnostic specificity against other soft-tissue lesions and a role in surgical decision-making were not assessed.

Zitieren

APA

Can, A., Şen, H., & Yıldıran, H. (2026). Hounsfield unit measurements on computed tomography in elastofibroma dorsi: a patient-level comparison with adjacent skeletal muscle. Langenbeck's Archives of Surgery. https://doi.org/10.1007/s00423-026-04199-9

Vancouver

Can A, Şen H, Yıldıran H. Hounsfield unit measurements on computed tomography in elastofibroma dorsi: a patient-level comparison with adjacent skeletal muscle. Langenbeck's Archives of Surgery. 2026. doi:10.1007/s00423-026-04199-9

BibTeX
@article{Can2026,
  author = {Can, Atilla and Şen, Halil and Yıldıran, Hüseyin},
  title = {Hounsfield unit measurements on computed tomography in elastofibroma dorsi: a patient-level comparison with adjacent skeletal muscle},
  journal = {Langenbeck's Archives of Surgery},
  year = {2026},
  doi = {10.1007/s00423-026-04199-9}
}
Kostenlos starten →