Fachartikel in der Zeitschrift Langenbeck's Archives of Surgery, 2024. Verfasst von Takayoshi Nakajima und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, Meiwa Hospital, 4-31 Agenaruo-cho, Nishinomiya, 663-8186, Japan. futurama1228@yahoo.co.jp. Hauptthemen laut MEDLINE: Hepatectomy, Liver Failure, Portal Pressure. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 35 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Predicting posthepatectomy liver failure (PHLF) may be a critical requirement for liver disease patients undergoing hepatectomy. This study retrospectively analyzed the impact of the intraoperatively measured portal vein pressure (PVP) prior to hepatectomy on the prediction of PHLF in hepatectomized patients. METHODS: A total of 334 hepatectomized patients in whom the PVP was intraoperatively measured before resection at our institution were enrolled in the present study. Outcomes were assessed according to the International Study Group of Liver Surgery definition and the severity of PHLF grading. RESULTS: Thirty-nine of the 334 patients (11.6%) developed grade B/C PHLF. The following factors were significantly associated with grade B/C PHLF in a univariate analysis: indocyanine green retention rate after 15 min, Child-Pugh score, prehepatectomy PVP, and transfusion (each P < 0.0001). A prehepatectomy PVP value of 19.5 cmH2O was the optimal cutoff value for predicting grade B/C PHLF. In a multivariate analysis, prehepatectomy PVP (≥ 19.5 cmH2O) was selected as the most relevant risk factor for grade B/C PHLF (P = 0.0003, hazard ratio: 5.96, 95% CI: 1.80-19.70). CONCLUSIONS: Prehepatectomy PVP can serve as a useful predictor of the risk of PHLF in patients who have undergone hepatectomy. The results emphasize the possibility of reducing the planned extent of hepatic resection when the prehepatectomy PVP value measured intraoperatively exceeds 19.5 cmH2O, and the importance of predicting the PVP before the operation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Surgery, Meiwa Hospital, 4-31 Agenaruo-cho, Nishinomiya, 663-8186, Japan. futurama1228@yahoo.co.jp.
- Department of Surgery, Meiwa Hospital, 4-31 Agenaruo-cho, Nishinomiya, 663-8186, Japan.
Zitieren
APA
Nakajima, T., Ikuta, S., Aihara, T., Ikuta, L., Matsuki, G., Fujikawa, M., Ichise, N., Okamoto, R., Nakamoto, Y., Yanagi, H., & Yamanaka, N. (2024). Intraoperatively measured prehepatectomy portal vein pressure as a useful predictor of posthepatectomy liver failure. Langenbeck's Archives of Surgery. https://doi.org/10.1007/s00423-024-03508-4
Vancouver
Nakajima T, Ikuta S, Aihara T, Ikuta L, Matsuki G, Fujikawa M, et al. Intraoperatively measured prehepatectomy portal vein pressure as a useful predictor of posthepatectomy liver failure. Langenbeck's Archives of Surgery. 2024. doi:10.1007/s00423-024-03508-4
BibTeX
@article{Nakajima2024,
author = {Nakajima, Takayoshi and Ikuta, Shinichi and Aihara, Tsukasa and Ikuta, Lisa and Matsuki, Goshi and Fujikawa, Masataka and Ichise, Noriko and Okamoto, Ryo and Nakamoto, Yoshihiko and Yanagi, Hidenori and Yamanaka, Naoki},
title = {Intraoperatively measured prehepatectomy portal vein pressure as a useful predictor of posthepatectomy liver failure},
journal = {Langenbeck's Archives of Surgery},
year = {2024},
doi = {10.1007/s00423-024-03508-4}
}
EUVIMED