EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Results of robotic liver surgery in association with IWATE criteria — the first 100 cases

Kira C Steinkraus, Benno Traub, Patrick Heger, Marin Zaimi, Andre L Mihaljevic, Christoph W Michalski, Marko Kornmann, Felix J Hüttner

Langenbeck's Archives of Surgery · 02.02.2024 · 409 (1)

DOI: 10.1007/s00423-024-03239-6 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Langenbeck's Archives of Surgery, online erschienen am 02.02.2024. Verfasst von Kira C Steinkraus und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of General and Visceral Surgery, Ulm University Hospital, Ulm, Germany. Hauptthemen laut MEDLINE: Robotic Surgical Procedures, Laparoscopy, Robotics, Liver Neoplasms. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 14 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universität Ulm.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Aim of the current study was to present the results of the implementation phase of a robotic liver surgery program and to assess the validity of the IWATE difficulty score in predicting difficulty and postoperative complications in robotic liver surgery.

Methods

Based on the prospective database of the Interdisciplinary Robotic Center of Ulm University Hospital, the first 100 robotic liver surgeries were identified and analyzed. Perioperative parameters (duration of surgery and blood loss) and postoperative parameters including morbidity, mortality, and length of hospital stay were assessed and the results were compared between different IWATE difficulty categories.

Results

From November 2020 until January 2023, 100 robotic liver surgeries were performed (41 female, 59 male; median age 60.6 years, median BMI 25.9 kg/m 2 ). Median duration of surgery was 180 min (IQR: 128.7), and median blood loss was 300 ml (IQR: 550). Ninety-day mortality was 2%, and overall morbidity was 21%, with major complications occurring in 13% of patients (≥ grade 3 according to Clavien/Dindo). A clinically relevant postoperative biliary leakage was observed in 3 patients. Posthepatectomy liver failure occurred in 7% (4 Grade A, 3 Grade B). Duration of surgery ( p < 0.001), blood loss ( p < 0.001), CCI ( p = 0.004), overall morbidity ( p = 0.004), and length of hospital stay ( p < 0.001) were significantly increased in the IWATE ‘expert’ category compared to lower categories.

Discussion

Robotic surgery offers a minimally invasive approach for liver surgery with favorable clinical outcomes, even in the implementation phase. In the current study the IWATE difficulty score had the ability to predict both difficulty of surgery as well as postoperative outcomes when assessing the complexity of robotic liver surgery. Therefore, the role of the IWATE score in predicting these outcomes highlights its importance as a tool in surgical planning and decision-making.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Robotic Surgical ProceduresLaparoscopyRoboticsLiver NeoplasmsHumansMaleFemaleMiddle AgedPostoperative ComplicationsLiverRetrospective StudiesLength of StayHepatectomy

Stichwörter der Autor:innen

IWATE criteriaRobotic liver surgerySurgical site infections

Autor:innen und Institutionen

  • Department of General and Visceral Surgery, Ulm University Hospital, Ulm, Germany.
  • Department of General, Visceral and Transplantation Surgery, Tübingen University Hospital, Tubingen, Germany.
  • Department of General, Visceral and Transplantation Surgery, Heidelberg University Hospital, Heidelberg, Germany.
  • Department of General and Visceral Surgery, Ulm University Hospital, Ulm, Germany. felix.huettner@uni-ulm.de.
  • Department of General, Visceral and Thoracic Surgery, Klinikum Nürnberg, Paracelsus Medical University, Nurnberg, Germany. felix.huettner@uni-ulm.de.

Förderung

  • Universität Ulm

Zitieren

APA

Steinkraus, K. C., Traub, B., Heger, P., Zaimi, M., Mihaljevic, A. L., Michalski, C. W., Kornmann, M., & Hüttner, F. J. (2024). Results of robotic liver surgery in association with IWATE criteria — the first 100 cases. Langenbeck's Archives of Surgery, 409(1). https://doi.org/10.1007/s00423-024-03239-6

Vancouver

Steinkraus KC, Traub B, Heger P, Zaimi M, Mihaljevic AL, Michalski CW, et al. Results of robotic liver surgery in association with IWATE criteria — the first 100 cases. Langenbeck's Archives of Surgery. 2024;409(1). doi:10.1007/s00423-024-03239-6

BibTeX
@article{Steinkraus2024,
  author = {Steinkraus, Kira C and Traub, Benno and Heger, Patrick and Zaimi, Marin and Mihaljevic, Andre L and Michalski, Christoph W and Kornmann, Marko and Hüttner, Felix J},
  title = {Results of robotic liver surgery in association with IWATE criteria — the first 100 cases},
  journal = {Langenbeck's Archives of Surgery},
  year = {2024},
  volume = {409},
  number = {1},
  doi = {10.1007/s00423-024-03239-6}
}
Kostenlos starten →