Influence of deception of task duration on the sex-specific physiological responses to RPE-clamp cycle ergometry
European Journal of Applied Physiology · 2025
DOI: 10.1007/s00421-024-05698-7 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Journal of Applied Physiology, 2025. Verfasst von Pasquale J Succi und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Kinesiology and Health Promotion, University of Kentucky, 1210 University Drive, Lexington, KY, 40526, USA. pjsucci@gmail.com. Hauptthemen laut MEDLINE: Exercise, Deception, Physical Exertion. Die Arbeit nennt 69 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIA NIH HHS, National Institute of Health, Arvle and Ellen Turner Thacker Research Fund.
Abstract (Originalsprache)
PURPOSE: The purpose of this study was to examine the sex-specific influence of expected exercise duration on the physiological responses to RPE-clamp exercise anchored to RPE 15 with participants being deceived into believing the RPE-clamp exercise would last for 20-, 30-, or 40-min, but all trials were 30-min. METHODS: Twelve males and 12 females completed a graded exercise test followed by randomly ordered RPE-clamp trials at RPE15 on the Borg 6-20 scale where subjects were deceived into expecting exercise to last for either 20-, 30-, or 40-min, but the actual duration for each trial was 30-min. Separate 2 (Sex [Male vs. Female]) × 3 (Deception [20-min, 30-min, 40-min]) × 11 (Time [0, 3, 6, 9, 12, 15, 18, 21, 24, 27, 30 min]) mixed model analyses of variance (ANOVAs) with appropriate follow-up ANOVAs, and Bonferroni-corrected pairwise comparisons, were used to examine changes in volume of oxygen uptake ( V ˙ O 2 ), heart rate (HR), respiration rate (RR), power output, and muscle oxygen saturation (%SmO2). RESULTS: Females, but not males, demonstrated lower power outputs when expected duration was 40-min compared to 20-min after approximately half of the exercise bout. V ˙ O 2 , regardless of Sex, was also lower when expected duration was 40-min (62.47 ± 5.59% V ˙ O 2 max ) compared to 20-min (66.35 ± 5.79% V ˙ O 2 max ). There was no effect of expected duration on HR, RR, or %SmO2, but females demonstrated significantly higher HR (86.06 ± 5.93%HRmax) and RR (74.81 ± 7.26%RRmax) compared to males (79.52 ± 4.96%HRmax; 62.31 ± 5.80%RRmax). CONCLUSIONS: RPE-clamp exercise performance in females, but not males, may be influenced by the expectation of exercise duration.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Kinesiology and Health Promotion, University of Kentucky, 1210 University Drive, Lexington, KY, 40526, USA. pjsucci@gmail.com.
- Department of Kinesiology and Health Promotion, University of Kentucky, 1210 University Drive, Lexington, KY, 40526, USA.
- Department of Athletic Training & Clinical Nutrition, University of Kentucky, Lexington, KY, USA.
Förderung
- NIA NIH HHS
- National Institute of Health
- Arvle and Ellen Turner Thacker Research Fund
Zitieren
APA
Succi, P. J., Benitez, B., Kwak, M., Mitchinson, C. J., Butterfield, T. A., Samaan, M. A., Clasey, J. L., & Bergstrom, H. C. (2025). Influence of deception of task duration on the sex-specific physiological responses to RPE-clamp cycle ergometry. European Journal of Applied Physiology. https://doi.org/10.1007/s00421-024-05698-7
Vancouver
Succi PJ, Benitez B, Kwak M, Mitchinson CJ, Butterfield TA, Samaan MA, et al. Influence of deception of task duration on the sex-specific physiological responses to RPE-clamp cycle ergometry. European Journal of Applied Physiology. 2025. doi:10.1007/s00421-024-05698-7
BibTeX
@article{Succi2025,
author = {Succi, Pasquale J and Benitez, Brian and Kwak, Minyoung and Mitchinson, Clara J and Butterfield, Timothy A and Samaan, Michael A and Clasey, Jody L and Bergstrom, Haley C},
title = {Influence of deception of task duration on the sex-specific physiological responses to RPE-clamp cycle ergometry},
journal = {European Journal of Applied Physiology},
year = {2025},
doi = {10.1007/s00421-024-05698-7}
}
EUVIMED