Fachartikel in der Zeitschrift European Journal of Applied Physiology, 2024. Verfasst von Letizia Rasica und 4 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Kinesiology, University of Calgary, Calgary, Canada. Hauptthemen laut MEDLINE: Spectroscopy, Near-Infrared, Oxygen Consumption, Muscle, Skeletal. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Sciences and Engineering Research Council of Canada, Heart & Stroke Foundation of Canada, Hamad bin Khalifa University.
Abstract (Originalsprache)
Purpose
Different strategies for near-infrared spectroscopy (NIRS)-derived muscle oxidative capacity assessment have been reported. This study compared and evaluated (I) approaches for averaging trials; (II) NIRS signals and blood volume correction equations; (III) the assessment of vastus lateralis (VL) and tibialis anterior (TA) muscles in two fitness levels groups.
Methods
Thirty-six participants [18 chronically trained (CT: 14 males, 4 females) and 18 untrained (UT: 10 males, 8 females)] participated in this study. Two trials of twenty transient arterial occlusions were performed for NIRS-derived muscle oxidative capacity assessment. Muscle oxygen consumption ( $$\dot{V}$$ V ˙ O 2 m ) was estimated from deoxygenated hemoglobin (HHb), corrected for blood volume changes following Ryan (HHbR) and Beever (HHbB) equations, and from oxygen saturation (StO 2 ) in VL and TA.
Results
Superimposing or averaging $$\dot{V}$$ V ˙ O 2 m or averaging the rate constants ( k ) from the two trials resulted in equivalent k values [two one-sided tests (TOST) procedure with 5% equivalence margin— P < 0.001]. Whereas HHbR (2.35 ± 0.61 min −1 ) and HHbB (2.34 ± 0.58 min −1 ) derived k were equivalent ( P < 0.001), StO 2 derived k (2.81 ± 0.92 min −1 ) was greater ( P < 0.001) than both. k values were greater in CT vs UT in both muscles (VL: + 0.68 min −1 , P = 0.002; TA: + 0.43 min −1 , P = 0.01).
Conclusion
Different approaches for averaging trials lead to similar k . HHb and StO 2 signals provided different k , although different blood volume corrections did not impact k . Group differences in k were detected in both muscles.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Faculty of Kinesiology, University of Calgary, Calgary, Canada.
- Department of Sport Science, University of Innsbruck, Innsbruck, Austria.
- Faculty of Kinesiology, University of Calgary, Calgary, Canada. jmurias@hbku.edu.qa.
- College of Health and Life Sciences, Hamad Bin Khalifa University, Doha, Qatar. jmurias@hbku.edu.qa.
Förderung
- Natural Sciences and Engineering Research Council of Canada
- Heart & Stroke Foundation of Canada
- Hamad bin Khalifa University
Zitieren
APA
Rasica, L., Inglis, E. C., Mazzolari, R., Iannetta, D., & Murias, J. M. (2024). Methodological considerations on near-infrared spectroscopy derived muscle oxidative capacity. European Journal of Applied Physiology. https://doi.org/10.1007/s00421-024-05421-6
Vancouver
Rasica L, Inglis EC, Mazzolari R, Iannetta D, Murias JM. Methodological considerations on near-infrared spectroscopy derived muscle oxidative capacity. European Journal of Applied Physiology. 2024. doi:10.1007/s00421-024-05421-6
BibTeX
@article{Rasica2024,
author = {Rasica, Letizia and Inglis, Erin Calaine and Mazzolari, Raffaele and Iannetta, Danilo and Murias, Juan M},
title = {Methodological considerations on near-infrared spectroscopy derived muscle oxidative capacity},
journal = {European Journal of Applied Physiology},
year = {2024},
doi = {10.1007/s00421-024-05421-6}
}
EUVIMED