An improved method for Gill’s hematoxylin and eosin staining based on the optimal acetic acid ratio
Histochemistry and Cell Biology · 01.08.2026 · 164 (1)
DOI: 10.1007/s00418-026-02522-5 ↗Kurz gefasst
Fachartikel in der Zeitschrift Histochemistry and Cell Biology, online erschienen am 01.08.2026. Verfasst von Zhijie Ma und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pathology, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, 310020, China. Hauptthemen laut MEDLINE: Acetic Acid, Staining and Labeling, Hematoxylin, Eosine Yellowish-(YS). Die Arbeit nennt 21 Literaturangaben. Gefördert von: National Natural Science Foundation of China, China Postdoctoral Science Foundation, Zhejiang Provincial Natural Science Foundation of China.
Abstract (Originalsprache)
The staining performance of hemalum solutions is critically dependent on pH, yet the acetic acid content varies among different hemalum formulations. This study aimed to clarify the relationship between the acetic acid ratio (pH) of Gill’s hemalum and optimal nuclear staining, and to improve the hematoxylin and eosin (H&E) staining method. Gill’s hemalum with varying acetic acid concentrations was used for H&E staining of surgical and biopsy specimens. Optimal nuclear staining was achieved at 3.48% acetic acid (pH 2.47), with pH deviations compromising staining quality. Tissue-specific differences in nuclear staining were observed: liver, prostate, and lung stained better than stomach, thyroid, and breast, and surgical specimens outperformed biopsies. Notably, the staining effect of overacidified Gill’s hemalum could not be restored by adding sodium hydroxide (NaOH). At the optimal pH, Gill’s hemalum surpassed Harris’ hemalum in nuclear staining quality. Furthermore, the addition of a pH buffer not only improved staining consistency but also significantly extended the usable lifespan of Gill’s hemalum. These findings indicate that the acetic acid concentration (pH) of Gill’s hemalum is a key quality control parameter for H&E staining. Gill’s hemalum prepared with 3.48% acetic acid and used with a pH buffer, offers significant practical value and is recommended for routine use in a pathology laboratory.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Pathology, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, 310020, China.
- Department of Gastroenterology, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, 310020, China.
- Department of Pathology, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, 310020, China. 3201013@zju.edu.cn.
Förderung
- National Natural Science Foundation of China
- China Postdoctoral Science Foundation
- Zhejiang Provincial Natural Science Foundation of China
Zitieren
APA
Ma, Z., Sheng, C., Wu, D., An, H., Tang, W., Zhao, P., & Fu, G. (2026). An improved method for Gill’s hematoxylin and eosin staining based on the optimal acetic acid ratio. Histochemistry and Cell Biology, 164(1). https://doi.org/10.1007/s00418-026-02522-5
Vancouver
Ma Z, Sheng C, Wu D, An H, Tang W, Zhao P, et al. An improved method for Gill’s hematoxylin and eosin staining based on the optimal acetic acid ratio. Histochemistry and Cell Biology. 2026;164(1). doi:10.1007/s00418-026-02522-5
BibTeX
@article{Ma2026,
author = {Ma, Zhijie and Sheng, Caixia and Wu, Danju and An, Huimin and Tang, Wen and Zhao, Ping and Fu, Guoxiang},
title = {An improved method for Gill’s hematoxylin and eosin staining based on the optimal acetic acid ratio},
journal = {Histochemistry and Cell Biology},
year = {2026},
volume = {164},
number = {1},
doi = {10.1007/s00418-026-02522-5}
}
EUVIMED