EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Comparative evaluation of GPT 5.2 Pro and Gemini 3 Pro large multimodal models for retinal optical coherence tomography interpretation

Victor Bellanda iD, David Shin, Cindy Chen, Yuka Mizuno iD, Sandeep Singh, Eliot N Haddad iD, Matthew J Schulgit iD, Nitesh Mohan iD, Sunil K Srivastava iD, Fares Antaki iD, Sumit Sharma iD

Graefe's Archive for Clinical and Experimental Ophthalmology · 16.11.2026

DOI: 10.1007/s00417-026-07604-7 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Graefe's Archive for Clinical and Experimental Ophthalmology, online erschienen am 16.11.2026. Verfasst von Victor Bellanda und 10 weiteren Autor:innen. Beteiligte Einrichtung: Cole Eye Institute, Cleveland Clinic, Cleveland, OH, USA. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Large multimodal models (LMMs) capable of interpreting medical images are increasingly accessible to patients, yet their reliability for retinal optical coherence tomography (OCT) interpretation remains uncertain. This study evaluated the performance of two state-of-the-art LMMs in detecting OCT features and generating diagnostic interpretations.

Methods

In this cross-sectional study, 330 publicly available retinal OCT B-scans spanning 12 diagnostic categories, including normal scans and common retinal diseases, were analyzed. Two commercially available LMMs (GPT 5.2 Pro and Gemini 3 Pro) were evaluated using zero-shot inference. Models were assessed separately for detection of nine predefined OCT features and for free-text diagnostic interpretation. Feature detection performance was measured using per-feature metrics and macro-averaged F1 scores, while diagnostic accuracy was assessed against expert-adjudicated reference standards.

Results

Gemini 3 Pro demonstrated higher feature detection performance than GPT 5.2 Pro (macro-averaged F1 score 0.558 vs. 0.472) and higher diagnostic accuracy (58.8% vs. 32.1%). Both models performed better for visually salient abnormalities but showed limited sensitivity for subtle structural features. Normal OCT scans were frequently misclassified as pathological, particularly by GPT 5.2 Pro, which failed to correctly identify any normal images. Recurrent, model-specific diagnostic biases and hallucinated diagnoses were observed.

Conclusions

Although LMMs can extract clinically relevant information from OCT scans, their diagnostic reliability remains limited, with frequent overcalling of pathology and systematic biases. Given their increasing availability to patients, these limitations raise concerns about potential misinterpretation outside supervised clinical settings. Careful validation and clear usage boundaries are needed before such tools can be safely integrated into patient-facing workflows.

Schlagwörter

Stichwörter der Autor:innen

Age-related macular degenerationArtificial intelligenceClinical decision support systemsDiabetesDiagnostic accuracyImagingMacular edemaMacular holeNatural language processingOphthalmologyVitreomacular traction

Autor:innen und Institutionen

  • Cole Eye Institute, Cleveland Clinic, Cleveland, OH, USA.
  • College of Medicine, The Ohio State University, Columbus, OH, USA.
  • Cole Eye Institute, Cleveland Clinic, Cleveland, OH, USA. sharmas@ccf.org.

ORCID-Profile: Victor Bellanda, Yuka Mizuno, Eliot N Haddad, Matthew J Schulgit, Nitesh Mohan, Sunil K Srivastava, Fares Antaki, Sumit Sharma

Zitieren

APA

Bellanda, V., Shin, D., Chen, C., Mizuno, Y., Singh, S., Haddad, E. N., Schulgit, M. J., Mohan, N., Srivastava, S. K., Antaki, F., & Sharma, S. (2026). Comparative evaluation of GPT 5.2 Pro and Gemini 3 Pro large multimodal models for retinal optical coherence tomography interpretation. Graefe's Archive for Clinical and Experimental Ophthalmology. https://doi.org/10.1007/s00417-026-07604-7

Vancouver

Bellanda V, Shin D, Chen C, Mizuno Y, Singh S, Haddad EN, et al. Comparative evaluation of GPT 5.2 Pro and Gemini 3 Pro large multimodal models for retinal optical coherence tomography interpretation. Graefe's Archive for Clinical and Experimental Ophthalmology. 2026. doi:10.1007/s00417-026-07604-7

BibTeX
@article{Bellanda2026,
  author = {Bellanda, Victor and Shin, David and Chen, Cindy and Mizuno, Yuka and Singh, Sandeep and Haddad, Eliot N and Schulgit, Matthew J and Mohan, Nitesh and Srivastava, Sunil K and Antaki, Fares and Sharma, Sumit},
  title = {Comparative evaluation of GPT 5.2 Pro and Gemini 3 Pro large multimodal models for retinal optical coherence tomography interpretation},
  journal = {Graefe's Archive for Clinical and Experimental Ophthalmology},
  year = {2026},
  doi = {10.1007/s00417-026-07604-7}
}
Kostenlos starten →