SD-OCT vs FA in diabetic retinopathy: a sensitivity-specificity tradeoff in detecting intraretinal macroaneurysms

Ismael Daoudi, David Rp Almeida, Braham Bodaghi, Eric K Chin, Nathalie Massamba

Graefe's Archive for Clinical and Experimental Ophthalmology · 21.08.2026

DOI: 10.1007/s00417-026-07465-0 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Graefe's Archive for Clinical and Experimental Ophthalmology, online erschienen am 21.08.2026. Verfasst von Ismael Daoudi und 4 weiteren Autor:innen. Beteiligte Einrichtung: Ophthalmology Department, Hôpitaux Universitaires de Bruxelles, Erasme Hospital, ULB, Brussels, Belgium. ismael.daoudi@ulb.be. Die Arbeit nennt 25 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To evaluate and compare the sensitivity and specificity of spectral-domain optical coherence tomography (SD-OCT) versus fluorescein angiography (FA) in detecting intraretinal macroaneurysms (IMAs) in patients with diabetic retinopathy (DR) in real-life clinical practice. METHODS: A retrospective, single-center study was conducted at the ophthalmology department of Pitié-Salpêtrière Hospital, Sorbonne University, from 2019 to September 2022. Fifty-eight eyes from 29 DR patients (mean age 50.2 ± 14.6 years) underwent comprehensive ophthalmological evaluation including slit-lamp examination, MultiColor confocal fundus imaging, and multimodal imaging with FA and SD-OCT (Heidelberg Spectralis HRA + OCT). IMAs were defined as aneurysmal dilations ≥ 150 μm. Because no independent gold standard (e.g., histology) was available, the consensus interpretation across both modalities served as the reference standard, and the resulting incorporation dependency is acknowledged as a limitation. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) with 95% confidence intervals (CIs) were calculated for each modality, with McNemar's test comparing sensitivities. Cohen's kappa assessed inter-reader agreement. RESULTS: SD-OCT demonstrated significantly higher sensitivity (92.3%; 95% CI: 79.1-98.4) than FA (48.7%; 95% CI: 32.4-65.2) for IMA detection (p < 0.05). Conversely, FA exhibited higher specificity (63.2%; 95% CI: 38.4-83.7) than SD-OCT (47.4%; 95% CI: 24.4-71.1). The PPV and NPV were 78.3% and 75.0% for SD-OCT, and 73.1% and 37.5% for FA. Inter-reader agreement was moderate to substantial (κ = 0.69 for SD-OCT; κ = 0.51 for FA). CONCLUSION: In this cohort, SD-OCT showed superior sensitivity but lower specificity than FA for detecting IMAs in patients with DR. This suggests SD-OCT is highly effective for identifying potential IMAs based on structural characteristics, while FA remains valuable for confirming activity based on leakage. The non-invasive nature and high detection rate of SD-OCT support its role as a primary tool in the routine diagnostic workflow for IMAs in DR. Further prospective, multi-center studies are warranted.

Schlagwörter

Stichwörter der Autor:innen

Diabetic retinopathyFluorescein angiographyIntraretinal macroaneurysmRetinal macroaneurysmRetinal microaneurysmSensitivitySpecificitySpectral-domain optical coherence tomography

Autor:innen und Institutionen

  • Ophthalmology Department, Hôpitaux Universitaires de Bruxelles, Erasme Hospital, ULB, Brussels, Belgium. ismael.daoudi@ulb.be.
  • Erie Retina Research, Erie, PA, USA.
  • Ophthalmology Department, Pitié-Salpêtrière Hospital, UPMC, Paris, France.
  • Retina Consultants of Southern California, Redlands, CA, USA.
  • Department of Ophthalmology, Loma Linda University Medical Center, Loma Linda, CA, USA.

Zitieren

APA

Daoudi, I., Almeida, D. R., Bodaghi, B., Chin, E. K., & Massamba, N. (2026). SD-OCT vs FA in diabetic retinopathy: a sensitivity-specificity tradeoff in detecting intraretinal macroaneurysms. Graefe's Archive for Clinical and Experimental Ophthalmology. https://doi.org/10.1007/s00417-026-07465-0

Vancouver

Daoudi I, Almeida DR, Bodaghi B, Chin EK, Massamba N. SD-OCT vs FA in diabetic retinopathy: a sensitivity-specificity tradeoff in detecting intraretinal macroaneurysms. Graefe's Archive for Clinical and Experimental Ophthalmology. 2026. doi:10.1007/s00417-026-07465-0

BibTeX
@article{Daoudi2026,
  author = {Daoudi, Ismael and Almeida, David Rp and Bodaghi, Braham and Chin, Eric K and Massamba, Nathalie},
  title = {SD-OCT vs FA in diabetic retinopathy: a sensitivity-specificity tradeoff in detecting intraretinal macroaneurysms},
  journal = {Graefe's Archive for Clinical and Experimental Ophthalmology},
  year = {2026},
  doi = {10.1007/s00417-026-07465-0}
}
Kostenlos starten →