Axial length–based reference values for corneal sensitivity in a pediatric population

Irem Onal, Begum Aydin, Yusuf Berk Akbas, Fahri Onur Aydin, Burcu Nurozler Tabakci, Emre Avci, Seda Duran Guler, Burcin Kepez Yildiz

Graefe's Archive for Clinical and Experimental Ophthalmology · 12.06.2026

DOI: 10.1007/s00417-026-07328-8 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Graefe's Archive for Clinical and Experimental Ophthalmology, online erschienen am 12.06.2026. Verfasst von Irem Onal und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, University of Health Sciences, Basaksehir Cam and Sakura City Hospital, Istanbul, Turkey. iiremonal@gmail.com. Die Arbeit nennt 56 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

What is known Corneal sensitivity is influenced by corneal innervation and has been shown to decrease in highly myopic adult eyes. What is new Corneal sensitivity is significantly reduced in eyes with high axial length (≥26 mm) across all corneal regions in healthy children. Among the structural parameters examined, axial length showed the most consistent independent association with corneal sensitivity across all corneal regions after adjustment for potential confounders.

Purpose

To investigate the relationship between axial length (AL) and corneal sensitivity (CS) in healthy pediatric eyes and to establish preliminary corneal sensitivity reference values across different AL groups.

Methods

This prospective, cross-sectional study included 353 children aged 5–18 years. AL was categorized into four groups: ≤22 mm, 22.01–23.99 mm, 24.0–25.99 mm, and ≥ 26 mm. CS was assessed in five corneal quadrants (central, superior, inferior, nasal, temporal) using a Cochet–Bonnet esthesiometer. Subgroup analyses were performed according to age groups. Non-parametric statistical analyses were applied to compare sensitivity values among AL groups.

Results

CS differed significantly across AL groups in all measured quadrants (overall p-values: central p = 0.005; superior p = 0.009; inferior p < 0.001; nasal p < 0.001; temporal p < 0.001). In eyes with AL≥26 mm, corneal sensitivity was significantly reduced in all quadrants compared with the AL≤22 mm group (all p ≤ 0.002). However, not all pairwise comparisons reached statistical significance, particularly those involving the 22.01–23.99 mm and 24.0–25.99 mm groups. Spearman correlation demonstrated a weak negative association between AL and CS across all quadrants ( r = − 0.125 to − 0.212, p = 0.019 to < 0.001). In the primary adjusted model including age, sex, and CCT, AL remained independently associated with lower corneal sensitivity across all corneal quadrants.

Conclusion

In pediatric eyes, CS differed across AL groups and was lower in eyes with AL≥26 mm. This association remained evident after adjustment for age, sex, and CCT; however, given the uneven distribution of age-stratified subgroups, these findings should be interpreted with caution. These results provide preliminary reference data for pediatric corneal sensitivity and suggest that axial elongation may be associated with alterations in corneal sensory function.

Schlagwörter

Stichwörter der Autor:innen

Axial myopiaCochet–Bonnet esthesiometerCorneal sensitivityHigh myopia

Autor:innen und Institutionen

  • Department of Ophthalmology, University of Health Sciences, Basaksehir Cam and Sakura City Hospital, Istanbul, Turkey. iiremonal@gmail.com.
  • Sarıkamis State Hospital, Kars, Turkey. iiremonal@gmail.com.
  • Department of Ophthalmology, University of Health Sciences, Basaksehir Cam and Sakura City Hospital, Istanbul, Turkey.

Zitieren

APA

Onal, I., Aydin, B., Akbas, Y. B., Aydin, F. O., Nurozler Tabakci, B., Avci, E., Duran Guler, S., & Kepez Yildiz, B. (2026). Axial length–based reference values for corneal sensitivity in a pediatric population. Graefe's Archive for Clinical and Experimental Ophthalmology. https://doi.org/10.1007/s00417-026-07328-8

Vancouver

Onal I, Aydin B, Akbas YB, Aydin FO, Nurozler Tabakci B, Avci E, et al. Axial length–based reference values for corneal sensitivity in a pediatric population. Graefe's Archive for Clinical and Experimental Ophthalmology. 2026. doi:10.1007/s00417-026-07328-8

BibTeX
@article{Onal2026,
  author = {Onal, Irem and Aydin, Begum and Akbas, Yusuf Berk and Aydin, Fahri Onur and Nurozler Tabakci, Burcu and Avci, Emre and Duran Guler, Seda and Kepez Yildiz, Burcin},
  title = {Axial length–based reference values for corneal sensitivity in a pediatric population},
  journal = {Graefe's Archive for Clinical and Experimental Ophthalmology},
  year = {2026},
  doi = {10.1007/s00417-026-07328-8}
}
Kostenlos starten →