Objective structured assessment of posterior capsular rupture management
Graefe's Archive for Clinical and Experimental Ophthalmology · 11.06.2026
DOI: 10.1007/s00417-026-07320-2 ↗Kurz gefasst
Fachartikel in der Zeitschrift Graefe's Archive for Clinical and Experimental Ophthalmology, online erschienen am 11.06.2026. Verfasst von Gilles C Martin und 8 weiteren Autor:innen. Beteiligte Einrichtung: University of Rennes, INSERM, LTSI - UMR 1099, Rennes, F35000, France. gilles.martin@umontreal.ca. Die Arbeit nennt 26 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: Posterior capsular rupture (PCR) management requires specific technical skills. Simulation-based training may support skill acquisition but requires validated, procedure-specific assessment tools. This study aimed to develop and validate a structured scale for assessing technical performance during PCR management. METHODS: The Objective Structured Assessment of Posterior Capsular Rupture (OSA-PCR) was developed using a Delphi consensus process involving 20 cataract surgeons. Validation was subsequently conducted in a prospective simulation-based study including 12 residents and surgeons, who performed two standardized PCR scenarios on a virtual-reality simulator, separated by structured instructor-guided training. The 24 recorded performances were independently evaluated by four experts. Psychometric evaluation of the OSA-PCR included reliability, internal consistency, construct validity, and responsiveness, with correlation to simulator scores. RESULTS: The final OSA-PCR comprised 19 items, all achieving 100% consensus in the third Delphi round. Interrater reliability was excellent (ICC[2,1] = 0.95; 95% CI, 0.89-0.98; ICC[2,4] = 0.90; 95% CI, 0.77-0.96), as was intrarater reliability (ICC[3,1] = 0.98). Internal consistency was high (Cronbach α = 0.93; McDonald ω = 0.94). OSA-PCR scores showed strong correlation with EyeSi Surgical scores (r = 0.90; 95% CI, 0.77-0.96) while providing greater discrimination among lower-performing cases. Scores improved significantly after training (median 63.5 vs. 96.6; P = 0.0005) but did not differ significantly across experience levels (P = 0.71). CONCLUSION: The OSA-PCR is a valid, reliable, and responsive instrument for assessing technical performance during simulated PCR management. It enables structured, procedure-specific evaluation and may support competency-based training and assessment in cataract surgery education.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- University of Rennes, INSERM, LTSI - UMR 1099, Rennes, F35000, France. gilles.martin@umontreal.ca.
- Ophthalmology Department, University of Montreal, Montreal, QC, Canada. gilles.martin@umontreal.ca.
- Centre d'Apprentissage des Attitudes et Habiletés Cliniques (CAAHC), Centre de Recherche en Pédagogie de la Santé, University of Montreal, Montreal, QC, Canada. gilles.martin@umontreal.ca.
- Centre d'Apprentissage des Attitudes et Habiletés Cliniques (CAAHC), Centre de Recherche en Pédagogie de la Santé, University of Montreal, Montreal, QC, Canada.
- Aguiléra Clinic, Biarritz, France.
- , Ophtalea, Bayonne, France.
Zitieren
APA
Martin, G. C., Tanoubi, I., Manassero, A., Aubineau, A., Chapron, T., Guindolet, D., Huaulmé, A., Jannin, P., & Mouriaux, F. (2026). Objective structured assessment of posterior capsular rupture management. Graefe's Archive for Clinical and Experimental Ophthalmology. https://doi.org/10.1007/s00417-026-07320-2
Vancouver
Martin GC, Tanoubi I, Manassero A, Aubineau A, Chapron T, Guindolet D, et al. Objective structured assessment of posterior capsular rupture management. Graefe's Archive for Clinical and Experimental Ophthalmology. 2026. doi:10.1007/s00417-026-07320-2
BibTeX
@article{Martin2026,
author = {Martin, Gilles C and Tanoubi, Issam and Manassero, Anthony and Aubineau, Anaïs and Chapron, Thibaut and Guindolet, Damien and Huaulmé, Arnaud and Jannin, Pierre and Mouriaux, Frédéric},
title = {Objective structured assessment of posterior capsular rupture management},
journal = {Graefe's Archive for Clinical and Experimental Ophthalmology},
year = {2026},
doi = {10.1007/s00417-026-07320-2}
}
EUVIMED