A large comprehensive comparison of large language models on ophthalmology board exams
Graefe's Archive for Clinical and Experimental Ophthalmology · 2026-11 · 264 (11) · 3553-3562
DOI: 10.1007/s00417-026-07264-7 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Graefe's Archive for Clinical and Experimental Ophthalmology, online erschienen am 14.05.2026. Verfasst von Alon Moore Galindo und 6 weiteren Autor:innen. Beteiligte Einrichtung: Ophthalmology Division, Tel Aviv Sourasky Medical Center, Weizmann St 6, Tel Aviv, 6423906, Israel. alonmor289@gmail.com. Hauptthemen laut MEDLINE: Large Language Models, Ophthalmology, Specialty Boards, Internship and Residency. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 30 Literaturangaben.
Abstract (Originalsprache)
What is known Small-scale studies with older models showed inconsistent performance, especially on image-based and subspecialty questions, highlighting the need for more robust benchmarking. What is new Largest evaluation to date : Provides the most comprehensive comparison of leading AI models on ophthalmology board-exam questions. New performance benchmarks : Gemini 2.5 Pro achieved the highest accuracy, 82.1% (95% CI,79.3–84.8), followed by ChatGPT-5 at 74.4% (95% CI 71.3–77.5), both models substantially exceeding the human benchmark. Performance limitations and Reliability insights : All models show marked declines on high-difficulty, Logical questions, and image-based questions. In addition, self-confidence analysis shows ChatGPT-5 as the most accurately calibrated model.
Purpose
A comprehensive performance evaluation of seven state-of-the-art large language models (LLMs) compared to human resident benchmarks on ophthalmology board exam questions. Furthermore, this study aims to define current model strengths and limitations while validating an assessment tool for clinicians to evaluate model-generated outputs.
Methods
Seven LLMs were assessed: ChatGPT-5, ChatGPT-4, Gemini 2.5 Pro, Gemini 2.5 Flash, Claude Sonnet 4.5, Grok-4-Fast-Reasoning, and Perplexity Sonar Pro. A dataset of 1,037 Israeli ophthalmology board questions (2020–2025) was manually categorized by question type (logical vs. informative), image modality, and 12 subspecialties. Models were evaluated for accuracy compared with resident performance, response latency, question difficulty, and self-assessed confidence.
Results
Performance varied substantially across models. Gemini 2.5 Pro achieved the highest accuracy, followed by ChatGPT-5, both outperforming residents. Accuracy declined significantly with increasing question difficulty (Very Hard vs. Easy: aOR 0.28, 95% CI,0.16–0.46; aP < 0.001), mirroring resident trends. Questions containing images were significantly more challenging for all models. Logical reasoning questions were significantly more challenging for LLMs than informative ones (aOR 0.66, aP = 0.019). Confidence calibration varied widely, with ChatGPT-5 showing superior discrimination (AUC = 0.827).
Conclusions
LLMs’ performance on ophthalmology board questions varied across models. Gemini 2.5 Pro achieved the highest performance, surpassing the mean resident score. However, the majority of LLMs exhibit significant error rates and poor calibration of self-assessed confidence. To safely integrate LLMs into the clinical workflow, continuous evaluation is essential to guide ophthalmologists on LLMs’ characteristics and clinical limitations.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Ophthalmology Division, Tel Aviv Sourasky Medical Center, Weizmann St 6, Tel Aviv, 6423906, Israel. alonmor289@gmail.com.
- Ophthalmology Division, Tel Aviv Sourasky Medical Center, Weizmann St 6, Tel Aviv, 6423906, Israel.
- Computer Science Department, Saint Joseph's University, Philadelphia, USA.
- Clinical Research Center, Soroka University Medical Center, Beer-Sheva, Israel.
- The Goldschleger Eye Institute, Sheba Medical Center, Tel-Aviv, Israel.
- Gray Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel.
Zitieren
APA
Galindo, A. M., Saadi, R., Kerman, T., Schwartzman, D., Pasternak, D., Kinori, M., & Loewenstein, A. (2026). A large comprehensive comparison of large language models on ophthalmology board exams. Graefe's Archive for Clinical and Experimental Ophthalmology, 264(11), 3553-3562. https://doi.org/10.1007/s00417-026-07264-7
Vancouver
Galindo AM, Saadi R, Kerman T, Schwartzman D, Pasternak D, Kinori M, et al. A large comprehensive comparison of large language models on ophthalmology board exams. Graefe's Archive for Clinical and Experimental Ophthalmology. 2026;264(11):3553-3562. doi:10.1007/s00417-026-07264-7
BibTeX
@article{Galindo2026,
author = {Galindo, Alon Moore and Saadi, Razan and Kerman, Tomer and Schwartzman, David and Pasternak, Doron and Kinori, Michael and Loewenstein, Anat},
title = {A large comprehensive comparison of large language models on ophthalmology board exams},
journal = {Graefe's Archive for Clinical and Experimental Ophthalmology},
year = {2026},
volume = {264},
number = {11},
pages = {3553--3562},
doi = {10.1007/s00417-026-07264-7}
}
EUVIMED