Fachartikel in der Zeitschrift Graefe's Archive for Clinical and Experimental Ophthalmology, 2025. Verfasst von Mateus Lins Dos Santos und 5 weiteren Autor:innen. Beteiligte Einrichtung: Hospital de Olhos de Sergipe, R. Campo do Brito, 995, São José, Aracaju, SE, 49020-380, Brazil. Hauptthemen laut MEDLINE: Intravitreal Injections, Syringes, Clinical Competence, Ophthalmology. Die Arbeit nennt 53 Literaturangaben. Gefördert von: SJJ Solutions.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To evaluate the accuracy of intravitreal injection (IVI) volumes under varying environmental conditions and operator training levels. METHODS: Three syringe models (Becton-Dickinson Plastipak 1mL, Aflibercept Prefilled Syringe, and Zero Residual Silicone Oil-Free 0.2 mL) were tested with 30G needles. Distilled water was drawn against different background colors (beige, black, blue, green, and white) by a single trained operator. Later, three different operators (a medical student, an ophthalmology resident, and a vitreoretinal surgeon) performed the injections under three training conditions (no prior training, after proper training, and forced plunger depression). The 50 µl of water were expelled into Eppendorf tubes and both syringes and tubes were weighed before and after injection. The main parameters measured were the effective delivered volume and residual volume. RESULTS: Significant differences were found among syringes (p < 0.001). Operator proficiency (p = 0.007) and training status (p < 0.001) also influenced volume accuracy. Post-hoc analysis revealed significant differences between clear green and black (p = 0.007), and between beige and black backgrounds (p = 0.008). CONCLUSIONS: Our study revealed significant variations in IVI volumes, influenced by syringe type, operator proficiency, and background color. These findings emphasize the need to consider materials and techniques for precision in IVI.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Intravitreal InjectionsSyringesClinical CompetenceOphthalmologyRecombinant Fusion ProteinsReceptors, Vascular Endothelial Growth FactorEducation, Medical, GraduateInternship and ResidencyHumansAngiogenesis InhibitorsEquipment DesignVascular Endothelial Growth Factor A

Stichwörter der Autor:innen

Intravitreal drug administrationIntravitreal injectionsMedical educationSyringes

Substanzen

Angiogenesis InhibitorsRecombinant Fusion ProteinsReceptors, Vascular Endothelial Growth FactorafliberceptVascular Endothelial Growth Factor A

Autor:innen und Institutionen

  • Hospital de Olhos de Sergipe, R. Campo do Brito, 995, São José, Aracaju, SE, 49020-380, Brazil.
  • Federal University of São Paulo, São Paulo, SP, Brazil.
  • Federal University of Alagoas, Maceió, AL, Brazil.
  • Hospital de Olhos de Sergipe, R. Campo do Brito, 995, São José, Aracaju, SE, 49020-380, Brazil. gustavobmelo@yahoo.com.br.
  • Federal University of São Paulo, São Paulo, SP, Brazil. gustavobmelo@yahoo.com.br.
  • Retina Prime, Aracaju, SE, Brazil. gustavobmelo@yahoo.com.br.

Förderung

  • SJJ Solutions

Zitieren

APA

Dos Santos, M. L., Santos, L. A., Cardoso, A. L., Agra, L. L. M., Coelho, J. A. P. M., & Melo, G. B. (2025). Intravitreal injection delivered volume under different environmental and training conditions. Graefe's Archive for Clinical and Experimental Ophthalmology. https://doi.org/10.1007/s00417-025-07005-2

Vancouver

Dos Santos ML, Santos LA, Cardoso AL, Agra LLM, Coelho JAPM, Melo GB. Intravitreal injection delivered volume under different environmental and training conditions. Graefe's Archive for Clinical and Experimental Ophthalmology. 2025. doi:10.1007/s00417-025-07005-2

BibTeX
@article{DosSantos2025,
  author = {Dos Santos, Mateus Lins and Santos, Lucas Andrade and Cardoso, Alexandre Lima and Agra, Lydianne Lumack Monte and Coelho, Jorge Artur Peçanha Miranda and Melo, Gustavo Barreto},
  title = {Intravitreal injection delivered volume under different environmental and training conditions},
  journal = {Graefe's Archive for Clinical and Experimental Ophthalmology},
  year = {2025},
  doi = {10.1007/s00417-025-07005-2}
}
Kostenlos starten →