EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Anterior segment OCT for imaging PAUL® glaucoma implant patch grafts: a useful method for follow-up and risk management

Pascal Schipper, Constance Weber, Ke Lu, Siqi Fan, Verena Prokosch, Frank G Holz, Karl Mercieca

Graefe's Archive for Clinical and Experimental Ophthalmology · 2025

DOI: 10.1007/s00417-024-06708-2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Graefe's Archive for Clinical and Experimental Ophthalmology, 2025. Verfasst von Pascal Schipper und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, University Hospital Bonn, Ernst-Abbe-Str. 2, 53127, Bonn, Germany. pascal.schipper@ukbonn.de. Hauptthemen laut MEDLINE: Tomography, Optical Coherence, Glaucoma Drainage Implants, Glaucoma, Anterior Eye Segment. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universitätsklinikum Bonn.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aim

To evaluate a useful, non-contact method for the follow-up of pericardium patch graft changes in patients undergoing PAUL ® Glaucoma Implant (PGI) surgery using high-resolution anterior segment optical coherence tomography (OCT) to predict tube erosions.

Methods

Prospective analysis over six months of tube pericardium patch graft thickness of PGI surgical cases at the University Eye Hospital Bonn, Germany, from November 2021 to August 2022. In all eyes, Tutopatch ® (RTI Surgical, United States) pericardium was used to cover the implant intra-operatively. Anterior segment OCT (AS-OCT, Heidelberg ANTERION ® Swept-Source-OCT) examinations were performed following a standardized protocol to measure quantitative and qualitative aspects of the patch grafts before surgery, and at three and six months after surgery.

Results

Twenty-six eyes of 26 patients were included. Thickness of the patch material was 1188 µm (IQR 415 µm) directly after implantation and decreased over time to 1068 µm (IQR 478 µm) at 3 months and 846 µm (IQR 677 µm) at 6 months. No significant differences between groups were shown concerning gender ( p = 0.128), ethnicity ( p = 1.000), age ( p = 0.741), glaucoma type ( p = 0.173), other concurrent diseases ( p = 0.302), former glaucoma surgeries ( p = 1.000) and the quadrant of implantation ( p = 0.555). Five eyes developed implant exposure. When comparing eyes with and without tube exposure, no significant differences were shown in average patch thickness above the tube directly after implantation ( p = 0.476). However, significant differences in average thickness were observed at 3 months ( p = 0.013) and 6 months ( p = 0.005).

Conclusions

Pericardial patch grafts tend to thin over time which can be assessed by AS-OCT, the latter proving to be a useful method to follow-up patients who undergo patch graft implantation during PGI surgery. This investigation could potentially help identify patients at risk of tube exposure which in turn could lead to modification of patient management. It could also possibly be used in future studies to find more suitable patch materials.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, Optical CoherenceGlaucoma Drainage ImplantsGlaucomaAnterior Eye SegmentIntraocular PressurePericardiumHumansMaleFemaleProspective StudiesFollow-Up StudiesAgedMiddle Aged

Stichwörter der Autor:innen

Anterior segment OCTGlaucoma drainage devicesGlaucoma surgeryPAUL® glaucoma implantPatch graftsTube erosion

Autor:innen und Institutionen

  • Department of Ophthalmology, University Hospital Bonn, Ernst-Abbe-Str. 2, 53127, Bonn, Germany. pascal.schipper@ukbonn.de.
  • Department of Ophthalmology, University Hospital Bonn, Ernst-Abbe-Str. 2, 53127, Bonn, Germany.
  • Department of Ophthalmology, University Hospital Cologne, Cologne, Germany.

Förderung

  • Universitätsklinikum Bonn

Zitieren

APA

Schipper, P., Weber, C., Lu, K., Fan, S., Prokosch, V., Holz, F. G., & Mercieca, K. (2025). Anterior segment OCT for imaging PAUL® glaucoma implant patch grafts: a useful method for follow-up and risk management. Graefe's Archive for Clinical and Experimental Ophthalmology. https://doi.org/10.1007/s00417-024-06708-2

Vancouver

Schipper P, Weber C, Lu K, Fan S, Prokosch V, Holz FG, et al. Anterior segment OCT for imaging PAUL® glaucoma implant patch grafts: a useful method for follow-up and risk management. Graefe's Archive for Clinical and Experimental Ophthalmology. 2025. doi:10.1007/s00417-024-06708-2

BibTeX
@article{Schipper2025,
  author = {Schipper, Pascal and Weber, Constance and Lu, Ke and Fan, Siqi and Prokosch, Verena and Holz, Frank G and Mercieca, Karl},
  title = {Anterior segment OCT for imaging PAUL® glaucoma implant patch grafts: a useful method for follow-up and risk management},
  journal = {Graefe's Archive for Clinical and Experimental Ophthalmology},
  year = {2025},
  doi = {10.1007/s00417-024-06708-2}
}
Kostenlos starten →