Evaluation of a new portable corneal topography system for self-measurement using smartphones: a pilot study
Graefe's Archive for Clinical and Experimental Ophthalmology · 2024
DOI: 10.1007/s00417-024-06426-9 ↗Kurz gefasst
Fachartikel in der Zeitschrift Graefe's Archive for Clinical and Experimental Ophthalmology, 2024. Verfasst von Hidenaga Kobashi und 5 weiteren Autor:innen. Beteiligte Einrichtung: Tsubota Laboratory, Inc., Tokyo, Japan. himon@hotmail.co.jp. Hauptthemen laut MEDLINE: Corneal Topography, Smartphone, Cornea, Keratoconus. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 15 Literaturangaben. Gefördert von: Tokyo Metropolitan Small and Medium Enterprise Support Center.
Abstract (Originalsprache)
PURPOSE: Herein, we propose the use of the "KeraVio Ring", which is a portable, selfie-based, smartphone-attached corneal topography system that is based on the Placido ring videokeratoscope. The goal of this study was to evaluate and compare corneal parameters between KeraVio Ring and conventional corneal tomography images. METHODS: We designed the KeraVio Ring as a device comprising 3D-printed LED rings for generating Placido rings that can be attached to a smartphone. Two LED rings are attached to a cone-shaped device, and both corneas are illuminated. Selfies were taken using the KeraVio Ring attached to the smartphone without assistance from any of the examiners. Captured Placido rings on the cornea were analysed by intelligent software to calculate corneal parameters. Patients with normal, keratoconus, or LASIK-treated eyes were included. Anterior segment optical coherence tomography (AS-OCT) was also performed for each subject. RESULTS: We found highly significant correlations between the steepest and flattest keratometry, corneal astigmatism, and vector components obtained with the KeraVio Ring and AS-OCT. In subjects with normal, keratoconus, and LASIK-treated eyes, the mean difference in corneal astigmatism between the two devices was -0.8 ± 1.4 diopters (D) (95% limits of agreement (LoA), -3.6 to 2.0), -1.8 ± 3.7 D (95% LoA, -9.1 to 5.5), and -1.5 ± 1.3 D (95% LoA, -4.0 to 1.1), respectively. CONCLUSIONS: The experimental results showed that the corneal parameters obtained by the KeraVio Ring were correlated with those obtained with AS-OCT. The KeraVio Ring has the potential to address an unmet need by providing a tool for portable selfie-based corneal topography.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Tsubota Laboratory, Inc., Tokyo, Japan. himon@hotmail.co.jp.
- Department of Ophthalmology, Keio University, School of Medicine, Tokyo, Japan. himon@hotmail.co.jp.
- Ebina-Ekimae Eye Clinic, Kanagawa, Japan. himon@hotmail.co.jp.
- Tsubota Laboratory, Inc., Tokyo, Japan.
- Department of Ophthalmology, Keio University, School of Medicine, Tokyo, Japan.
- Dentsu ScienceJam, Inc., Tokyo, Japan.
Förderung
- Tokyo Metropolitan Small and Medium Enterprise Support Center
Zitieren
APA
Kobashi, H., Tsubota, K., Aoki, S., Kobayashi, M., Sumali, B., & Mitsukura, Y. (2024). Evaluation of a new portable corneal topography system for self-measurement using smartphones: a pilot study. Graefe's Archive for Clinical and Experimental Ophthalmology. https://doi.org/10.1007/s00417-024-06426-9
Vancouver
Kobashi H, Tsubota K, Aoki S, Kobayashi M, Sumali B, Mitsukura Y. Evaluation of a new portable corneal topography system for self-measurement using smartphones: a pilot study. Graefe's Archive for Clinical and Experimental Ophthalmology. 2024. doi:10.1007/s00417-024-06426-9
BibTeX
@article{Kobashi2024,
author = {Kobashi, Hidenaga and Tsubota, Kazuo and Aoki, Shunsuke and Kobayashi, Masaaki and Sumali, Brian and Mitsukura, Yasue},
title = {Evaluation of a new portable corneal topography system for self-measurement using smartphones: a pilot study},
journal = {Graefe's Archive for Clinical and Experimental Ophthalmology},
year = {2024},
doi = {10.1007/s00417-024-06426-9}
}
EUVIMED